Skip to main content
Log in

Plasma volume in acute hypoxia: comparison of a carbon monoxide rebreathing method and dye dilution with Evans' blue

  • ORIGINAL ARTICLE
  • Published:
European Journal of Applied Physiology and Occupational Physiology Aims and scope Submit manuscript

Abstract

Exposure to acute hypoxia is associated with changes in body fluid homeostasis and plasma volume (PV). This study compared a dye dilution technique using Evans' blue (PVEvans') with a carbon monoxide (CO) rebreathing method (PVCO) for measurements of PV in ten normal subjects at sea level and again 24 h after rapid passive ascent to high altitude (4,350 m). Hypobaric hypoxia decreased arterial oxygen saturation to 79 (74–83)% (mean with 95% confidence intervals). The PVEvans' remained unchanged from 3.49 (3.30–3.68) l at sea level to 3.46 (3.24–3.68) l at high altitude. In contrast PVCO decreased from 3.39 (3.17–3.61) l at sea level to 3.04 (2.75–3.33) l at high altitude (P < 0.05). Compared with sea level, this resulted in an increase of the mean bias between the two methods [from 0.11 (−0.05–0.27) l at sea level to 0.43 (0.26–0.60) l at high altitude] so that the ratio between PVEvans' and PVCO increased from 1.04 (0.99–1.09) at sea level to 1.15 (1.06–1.24) at high altitude (P < 0.05). In conclusion, the two methods were not interchangeable as measures of hypoxia-induced changes in PV. The mechanism responsible for the bias remains unknown, but it is suggested that the results may reflect a redistribution of albumin caused by the combined effects in hypoxia of both an increased capillary permeability to albumin and a decrease in PV. As a result, the small perivascular compartment of albumin beyond the endothelium may increase without changes in the overall albumin distribution volume.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Accepted: 31 October 1997

Rights and permissions

Reprints and permissions

About this article

Cite this article

Poulsen, T., Klausen, T., Richalet, JP. et al. Plasma volume in acute hypoxia: comparison of a carbon monoxide rebreathing method and dye dilution with Evans' blue. Eur J Appl Physiol 77, 457–461 (1998). https://doi.org/10.1007/s004210050360

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s004210050360

Navigation