A comparison of energy expenditure estimates from the Actiheart and Actical physical activity monitors during low intensity activities, walking, and jogging

  • Original Article
  • Published:
European Journal of Applied Physiology Aims and scope Submit manuscript

Abstract

Combining accelerometry with heart rate monitoring has been suggested to improve energy estimates, however, it remains unclear whether the single, currently existing commercially available device combining these data streams (Actiheart) provides improved energy estimates compared to simpler and less expensive accelerometry-only devices. The purpose of this study was to compare the validity of the heart rate (HR), accelerometry (ACC), and combined ACC/HR estimates of the Actiheart to the ACC estimates of the Actical during low and moderate intensity activities. Twenty-seven participants (mean age 26.3 ± 7.3) wore an Actical, Actiheart and indirect calorimeter (K4b2) while performing card playing, sweeping, lifting weights, walking and jogging activities. All estimates tended to underestimate energy, sometimes by substantial amounts. Viewed across all activities studied, there was no significant difference in the ability of the waist-mounted Actical and torso-mounted Actiheart (ACC, HR, ACC/HR) estimates to predict energy expenditure. However, the Actiheart provided significantly better estimates than the Actical for the activities in which acceleration of the pelvis is not closely related to energy expenditure (card playing, sweeping, lifting weights) and the Actical provided significantly better estimates for level walking and level jogging. Similar to a previous study, the ACC component of the Actiheart was found to be the weakest predictor of energy suggesting it may be responsible for the failure of the combined ACC/HR estimate to equal or better the estimates derived solely from a waist mounted ACC device.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

Similar content being viewed by others

References

  • Ainsile P, Reilly T, Westerterp K (2003) Estimating human energy expenditure; a review of techniques with particular reference to doubly labelled water. Sports Med 33:683–698

    Article  Google Scholar 

  • Albanes D, Conway JM, Taylor PR, Moe PW, Judd J (1990) Validation and comparison of eight physical activity questionnaires. Epidemiology 1:65–71

    Article  PubMed  CAS  Google Scholar 

  • Barreira TV, Kang M, Caputo JL, Farley S, Renfrow MS (2009) Validation of the Actiheart monitor for the measurement of physical activity. Int J Exerc Sci 2:60–71

    Google Scholar 

  • Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1:307–310

    PubMed  CAS  Google Scholar 

  • Brage S, Brage N, Franks PW, Ekelund U, Wong MY, Andersen LB, Froberg K, Wareham NJ (2003) Branched equation modeling of simultaneous accelerometry and heart rate monitoring improves estimate of directly measured physical activity energy expenditure. J Appl Physiol 96:343–351

    Article  PubMed  Google Scholar 

  • Brage S, Brage N, Franks PW, Ekelund U, Wareham NJ (2005) Reliability and validity of the combined heart rate and movement sensor Actiheart. Eur J Clin Nutr 59:561–570

    Article  PubMed  CAS  Google Scholar 

  • Brage S, Ekelund U, Brage N, Hennings MA, Froberg K, Franks PW, Wareham NJ (2007) Hierarchy of individual calibration levels for heart rate and accelerometry to measure physical activity. J Appl Physiol 103:682–692

    Article  PubMed  Google Scholar 

  • Chen KY, Bassett DR Jr (2005) The technology of accelerometry-based activity monitors: current and future. Med Sci Sports Exerc 37:S490–S500

    Article  PubMed  Google Scholar 

  • Corder K, Brage S, Wareham NJ, Ekelund U (2005) Comparison of PAEE from combined and separate heart rate and movement models in children. Med Sci Sports Exerc 37:1761–1767

    Article  PubMed  Google Scholar 

  • Crouter SE, Bassett DR Jr (2008) A new 2-regression model for the Actical accelerometer. Br J Sports Med 42:217–224

    Article  PubMed  CAS  Google Scholar 

  • Crouter SE, Churilla JR, Basset DR Jr (2006) Estimating energy expenditure using accelerometers. Eur J Appl Physiol 98:601–612

    Article  PubMed  Google Scholar 

  • Crouter SE, Churilla JR, Bassett DR Jr (2008) Accuracy of the Actiheart for the assessment of energy expenditure in adults. Eur J Clin Nutr 62:704–711

    Article  PubMed  CAS  Google Scholar 

  • Esliger DW, Tremblay MS (2006) Technical reliability assessment of three accelerometer models in a mechanical setup. Med Sci Sports Exerc 38:2173–2181

    Article  PubMed  Google Scholar 

  • Fransson E, Knutsson A, Westerholm P, Alfredsson L (2008) Indications of recall bias found in a retrospective study of physical activity and myocardial infarction. J Clin Epidemiol 61:840–847

    Article  PubMed  Google Scholar 

  • Haskell WL, Yee MC, Evans A, Irby PJ (1993) Simultaneous measurement of heart rate and body motion to quantitate physical activity. Med Sci Sports Exerc 25:109–115

    Article  PubMed  CAS  Google Scholar 

  • Heil DP (2006) Predicting activity energy expenditure using the Actical activity monitor. Res Q Exerc Sport 77:64–80

    PubMed  Google Scholar 

  • Husswirth C, Bigard AX, Le Chevalier JM (1997) The Cosmed K4 telemetry system as an accurate device for oxygen uptake measurements during exercise. Int J Sports Med 18:449–453

    Article  Google Scholar 

  • Klippel N, Heil D (2003) Validation of energy expenditure prediction algorithms in adults using the Actical electronic activity monitor. Med Sci Sports Exerc 35:P284

    Google Scholar 

  • Lissner L, Potischman N, Troiano R, Bengtsson C (2004) Recall of physical activity in the distant past: the 32-year follow-up of the prospective population study of women in Goteborg, Sweden. Am J Epidemiol 159:304–307

    Article  PubMed  Google Scholar 

  • McLaughlin JE, King GA, Howley ET, Basset DR Jr, Ainsworth BE (2001) Validation of the COSMED K2 b2 portable metaobolic system. Int J Sports Med 22:280–284

    Article  PubMed  CAS  Google Scholar 

  • Menz H, Lord S, RC F (2003) Acceleration patterns of the head and pelvis when walking on level and irregular surfaces. Gait Posture 18:35–46

    Article  PubMed  Google Scholar 

  • Montoye HJ, Kemper HCG, Saris WHM, Washburn RA (1996) Measuring physical activity and energy expenditure. Human Kinetcs, Champaign

    Google Scholar 

  • Moon JK, Butte NF (1996) Combined heart rate and activity improve estimates of oxygen consumption and carbon dioxide production rates. J Appl Physiol 81:1754–1761

    PubMed  CAS  Google Scholar 

  • Paffenbarger RS, Brand RJ, Sholtz RI, Jung DL (1978) Energy expenditure, cigarette smoking, and blood pressure level as related to death from specific diseases. Am J Epidemiol 108:12–18

    PubMed  Google Scholar 

  • Pfeiffer KA, Mciver KL, Dowda M, Almeida MJCA, Pate RR (2006) Validation and calibration of the Actical accelerometer in preschool children. Med Sci Sports Exerc 38:152–157

    Article  PubMed  Google Scholar 

  • Prince F, Winter D, Stergiou P, Walt S (1994) Anticipatory control of upper body balance during human locomotion. Gait Posture 2:19–25

    Article  Google Scholar 

  • Ratcliffe R, Holt K (1997) Low frequency shock absorption in human walking. Gait Posture 5:93–100

    Article  Google Scholar 

  • Rennie KL, Wareham NJ (1998) The validation of physical acitivity instruments for measuring energy expenditure; problems and pitfalls. Public Health Nutr 1:265–271

    Article  PubMed  CAS  Google Scholar 

  • Saltin B, Lindgarde F, Houston M, Horlin R, Nygaard E, Gad P (1979) Physical tolerance and glucose intolerance in middle-aged men with chemical diabetes. Diabetes 28:30–32

    PubMed  Google Scholar 

  • Speakman JR (1998) The history and theory of the doubly labelled water technique. Am J Clin Nutr 68:932s–938s

    PubMed  CAS  Google Scholar 

  • Strath SJ, Brage S, Ekelund U (2005) Integration of physiological and accelerometer data to improve physical activity assessment. Med Sci Sports Exerc 37:S563–S571

    Article  PubMed  Google Scholar 

  • Thompson D, Batterhan AM, Bock S, Robson C, Stokes K (2006) Assessment of low-to-moderate intensity physical activity thermogenesis in young adults using syncrhonized heart rate and accelerometry with branch-equation modeling. J Nutr 136:1037–1042

    PubMed  CAS  Google Scholar 

  • US Department of Health and Human Services (2000) Healthy people 2010

  • Welk GJ, Schaben JA, Morrow JR Jr (2004) Reliability of accelerometry-based activity monitors: a generalizability study. Med Sci Sports Exerc 36:1637–1645

    PubMed  Google Scholar 

Download references

Acknowledgments

The authors of this manuscript certify that all experiments conducted during this study were in compliance with the current laws of the USA.

Conflict of interest

The authors declare that they have no conflict of interest.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to David K. Spierer.

Additional information

Communicated by Klaas Westerterp.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Spierer, D.K., Hagins, M., Rundle, A. et al. A comparison of energy expenditure estimates from the Actiheart and Actical physical activity monitors during low intensity activities, walking, and jogging. Eur J Appl Physiol 111, 659–667 (2011). https://doi.org/10.1007/s00421-010-1672-7

Download citation

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00421-010-1672-7

Keywords

Navigation