Skip to main content
Log in

Finite element modelling of radial lentotomy cuts to improve the accommodation performance of the human lens

  • Refractive Surgery
  • Published:
Graefe's Archive for Clinical and Experimental Ophthalmology Aims and scope Submit manuscript

Abstract

Purpose

The use of a femtosecond laser to form planes of cavitation bubbles within the ocular lens has been proposed as a potential treatment for presbyopia. The intended purpose of these planes of cavitation bubbles (referred to in this paper as ‘cutting planes’) is to increase the compliance of the lens, with a consequential increase in the amplitude of accommodation. The current paper describes a computational modelling study, based on three-dimensional finite element analysis, to investigate the relationship between the geometric arrangement of the cutting planes and the resulting improvement in lens accommodation performance. The study is limited to radial cutting planes.

Methods

The effectiveness of a variety of cutting plane geometries was investigated by means of modelling studies conducted on a 45-year human lens.

Results

The results obtained from the analyses depend on the particular modelling procedures that are employed. When the lens substance is modelled as an incompressible material, radial cutting planes are found to be ineffective. However, when a poroelastic model is employed for the lens substance, radial cuts are shown to cause an increase in the computed accommodation performance of the lens. In this case, radial cuts made in the peripheral regions of the lens have a relatively small influence on the accommodation performance of the lens; the lentotomy process is seen to be more effective when cuts are made near to the polar axis.

Conclusions

When the lens substance is modelled as a poroelastic material, the computational results suggest that useful improvements in lens accommodation performance can be achieved, provided that the radial cuts are extended to the polar axis. Radial cuts are ineffective when the lens substance is modelled as an incompressible material. Significant challenges remain in developing a safe and effective surgical procedure based on this lentotomy technique.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8

Similar content being viewed by others

References

  1. Anderson HA, Hentz G, Glasser A, Stuebing KK, Manny RE (2008) Minus-lens-stimulated accommodative amplitude decreases sigmoidally with age: A study of objectively measured accommodative amplitudes from age 3. Invest Ophthalmol Vis Sci 49(7):2919–2926

    Article  PubMed  PubMed Central  Google Scholar 

  2. Barraquer RI, Michael R, Abreu R, Lamarca J, Tresserra F (2006) Human lens capsule thickness as a function of age and location along the sagittal lens perimeter. Invest Ophthalmol Vis Sci 47(5):2053–2060

    Article  PubMed  Google Scholar 

  3. Burd HJ, Judge SJ, Cross JA (2002) Numerical modelling of the accommodating lens. Vis Res 42(18):2235–2251

    Article  CAS  PubMed  Google Scholar 

  4. Hermans EA, Dubbelman M, van der Heijde GL, Heethaar RM (2007) The shape of the human lens nucleus with accommodation. J Vision 7 (10):16, 1–10

  5. Hermans EA, Dubbelman M, van der Heijde GL, Heethaar RM (2006) Estimating the external force acting on the human eye lens during accommodation by finite element modelling. Vis Res 46(21):3642–3650

    Article  CAS  PubMed  Google Scholar 

  6. Hermans EA, Dubbelman M, van der Heijde GL, Heethaar RM (2008) Change in the accommodative force on the lens of the human eye with age. Vis Res 48(1):119–126

    Article  CAS  PubMed  Google Scholar 

  7. Heys KR, Cram SL, Truscott RJW (2004) Massive increase in the stiffness of the human lens nucleus with age: The basis for presbyopia? Mol Vis 10:956–963

    PubMed  Google Scholar 

  8. Krag S, Andreassen TT (2003) Mechanical properties of the human lens capsule. Prog Retin Eye Res 22(6):749–767

  9. Krueger RR, Sun XK, Stroh J, Myers R (2001) Experimental increase in accommodative potential after neodymium: Yttrium-aluminum-garnet laser photodisruption of paired cadaver lenses. Ophthalmology 108(11):2122–2129

    Article  CAS  PubMed  Google Scholar 

  10. Lubatschowski H, Schumacher S, Fromm M, Wegener A, Hoffman H, Oberheide U, Gerten G (2010) Femtosecond lentotomy: Generating gliding planes inside the crystalline lens to regain accommodation. J Biophotonics 3(5-6):265–268

    Article  PubMed  Google Scholar 

  11. Rabbett RB (2007) Bennett & Rabbetts’ clinical visual optics. Elsevier/Butterworth Heinemann, Edinburgh

    Google Scholar 

  12. Ripken T, Oberheide U, Fromm M, Schumacher S, Gerten G, Lubatschowski H (2008) fs-Laser induced elasticity changes to improve presbyopic lens accommodation. Graefes Arch Clin Exp Ophthalmol 246(6):897–906

    Article  PubMed  Google Scholar 

  13. Schumacher S, Oberheide U, Fromm M, Ripken T, Ertmer W, Gerten G, Wegener A, Lubatschowski H (2009) Femtosecond laser induced flexibility change of human donor lenses. Vis Res 49(14):1853–1859

    Article  PubMed  Google Scholar 

  14. Stachs O, Schumacher S, Hovakimyan M, Fromm M, Heisterkamp A, Lubatschowski H, Guthoff R (2009) Visualization of femtosecond laser pulse-induced microincisions inside crystalline lens tissue. J Refract Surg 35(11):1979–1983

    Article  Google Scholar 

  15. Strenk SA, Semmlow JL, Strenk LM, Munoz P, Gronlund-Jacob J, DeMarco JK (1999) Age-related changes in human ciliary muscle and lens: A magnetic resonance imaging study. Invest Ophthalmol Vis Sci 40(6):1162–1169

    CAS  PubMed  Google Scholar 

  16. Weeber HA, Eckert G, Pechhold W, van der Heijde GL (2007) Stiffness gradient in the crystalline lens. Graefes Arch Clin Exp Ophthalmol 245(9):1357–1366

    Article  PubMed  Google Scholar 

  17. Weeber HA, van der Heijde GL (2007) On the relationship between lens stiffness and accommodative amplitude. Exp Eye Res 85(5):602–607

    Article  CAS  PubMed  Google Scholar 

  18. Wilde GS, Burd HJ, Judge SJ (2012) Shear modulus data for the human lens determined from a spinning lens test. Exp Eye Res 97(1):36–48

    Article  CAS  PubMed  PubMed Central  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to H. J. Burd.

Ethics declarations

Funding

The research described in this paper was supported by a research grant from Rowiak GmbH. The sponsor had no role in the design or conduct of the research.

Conflict of interest

The authors declare that they have no conflicts of interest.

Ethical approval

This article does not contain any studies with human participants or animals performed by any of the authors.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Burd, H.J., Wilde, G.S. Finite element modelling of radial lentotomy cuts to improve the accommodation performance of the human lens. Graefes Arch Clin Exp Ophthalmol 254, 727–737 (2016). https://doi.org/10.1007/s00417-016-3296-z

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00417-016-3296-z

Keywords

Navigation