Abstract

Blood expirated from the nose may leave a characteristic bloodstain at a crime scene which can provide important clues for reconstructing events during a violent assault. Little research has been done on the typical velocities, trajectories and size distribution that can be expected from expirated blood. An experimental fluid dynamics technique known as stereoscopic particle image velocimetry is used in this work to obtain the air velocity field inside and outside the nostrils during exhalation. A numerical model was then used to compute the trajectory of blood drops of 0.5 and 2 mm. The drops were tracked until ground plane impact below the nostril exit. Three heights were investigated, 1.5, 1.6 and 1.7 m. For an expiration flow rate of 32 l/min in vivo, there is a maximum exit velocity from the nostril of approximately 4 m/s, with a 0.5 m/s difference between nostrils. After the drops have traversed the distances investigated, drops of 0.5 and 2 mm in diameter from both nostrils are at a similar velocity. This implies that the gravitational acceleration after the drops leave the jet has the most influence on velocity. It is however shown that exit velocity does affect impact location. Drop size affects both impact location and impact velocity. An increase in height increases the distance traversed. Compared to the 2-mm drop, the 0.5 mm had a lower impact velocity, but its impact location in the ground plane was further from the nostril exit. Understanding the physics of expirated blood flight allows better interpretation of expirated stains at crime scenes.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6

Similar content being viewed by others

References

  1. N. Carolina, vs. Petersen (2003). N. Carolina

  2. Davidson PL, Taylor MC, Wilson SJ, Walsh K, Kieser JK (2012) Physical components of soft-tissue ballistic wounding and their involvement in the generation of blood backspatter. J Forensic Sci 57:1339–1342

    Article  PubMed  Google Scholar 

  3. National Research Council (2009) Strengthening forensic science in the United States: a path forward

  4. Raffel M, Willert CE, Wereley ST, Kompenhans J (2007) Particle image velocimetry: a practical guide second edition. 2nd edn. Springer (Berlin and New York)

  5. Kabaliuk N, Jermy MC, Williams E, Laber TL, Taylor MC (2014) Experimental validation of a numerical model for predicting the trajectory of blood drops in typical crime scene conditions, including droplet deformation and breakup, with a study of the effect of indoor air currents and wind on typical spatter drop trajectories. Forensic Sci Int 245:107–120. doi:10.1016/j.forsciint.2014.10.020

  6. Donaldson AE, Walker NK, Lamont IL, Cordiner SJ, Taylor MC (2011) Characterising the dynamics of expirated bloodstain pattern formation using high-speed digital video imaging. Int J Legal Med 125(6):757–762. doi:10.1007/s00414-010-0498-5

    Article  PubMed  Google Scholar 

  7. Denison D, Porter A, Mills M, Schroter RC (2011) Forensic implications of respiratory derived blood spatter distributions. Forensic Sci Int 204(1–3):144–155. doi:10.1016/j.forsciint.2010.05.017

    Article  PubMed  Google Scholar 

  8. Geoghegan PH, Spence CJT, Kabaliuk N, Wilhelm J, Aplin J, Taylor MC, Jermy MC The flow field external to the human nose and the acceleration of blood drops from the nasal cavity during violent assault. In: 17th International symposium of laser techniques to fluid mechanics, Lisbon, Portugal, 7th-10th July 2014

  9. Geoghegan PH, Buchmann NA, Spence CJT, Moore S, Jermy M (2012) Fabrication of rigid and flexible refractive-index-matched flow phantoms for flow visualisation and optical flow measurements. Exp Fluids 52(5):1331–1347. doi:10.1007/s00348-011-1258-0

    Article  CAS  Google Scholar 

  10. Charm S, Kurland G (1965) Viscometry of human blood for shear rates of 0–100,000 sec − 1. Nature 206:617–618

    Article  CAS  PubMed  Google Scholar 

  11. Lowe G, Barbenel J (1988) Plasma and blood viscosity. Clin Blood Rheology 1:11–44

    Google Scholar 

  12. Rosina J, Kvasnák E, Suta D, Kolárová H, Málek J, Krajci L (2007) Temperature dependence of blood surface tension. Physiol Res 56(Suppl 1):S93–S98

    PubMed  Google Scholar 

  13. van Boxel JH Numerical model for the fall speed of rain drops in a rain fall simulator. In: Proceedings of the international workshop on technical aspects and use of wind tunnels for wind-erosion control: combined effects of wind and water erosion on processes, November 17–18 1997, Ghent, Belgium, 1998. pp 77–85

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to P. H. Geoghegan.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Geoghegan, P.H., Spence, C.J.T., Wilhelm, J. et al. Experimental and computational investigation of the trajectories of blood drops ejected from the nose. Int J Legal Med 130, 563–568 (2016). https://doi.org/10.1007/s00414-015-1163-9

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00414-015-1163-9

Keywords

Navigation