Abstract
Recently, a numerical method was proposed to correct the imaging plate (IP) response to 90Sr concentration in tooth samples, depending on the sample thickness. This is important to quantify any 90Sr concentration in teeth, which in turn is necessary to determine any 90Sr incorporation of a person retrospectively. Although the final goal will be to evaluate the (inhomogeneous) spatial distribution of 90Sr inside tooth samples precisely, the present study was restricted—as a first step—to the evaluation of 90Sr in teeth assuming a uniform 90Sr distribution. A numerical method proposed earlier was validated experimentally in the present study by measuring the IP response to standard sources of various thicknesses and 90Sr concentrations. For comparison, the energy deposition of the β-rays emitted by 90Sr in the IP—which is considered to be proportional to the IP luminescence signal—was calculated for the various sample thicknesses involved, by means of the MCNP-4C code. As a result, the measured IP response could be reproduced by the calculations within the uncertainties, depending on the thickness of the standard sources. Thus, the validity of the proposed numerical method to correct the IP response for sample thickness has successfully been demonstrated.
Similar content being viewed by others
References
Mokrov YG (2004) External radiation exposure of residents living close to the Mayak facility: main sources, dose estimates, and comparison with earlier assessments. Radiat Environ Biophys 43:127–139
Howard BJ, Semioschkina N, Voigt G, Mukusheva M, Clifford J (2004) Radiostrontium contamination of soil and vegetation within the Semipalatinsk test site. Radiat Environ Biophys 43:285–292
Li WB, Hollriegl V, Roth P, Oeh U (2006) Human Biokinetics of strontium. Part I: intestinal absorption rate and its impact on the dose coefficient of 90Sr after ingestion. Radiat Environ Biophys 43:115–124
Putyatin YV, Seraya TM, Petrykevich OM, Howard BJ (2006) Comparison of the accumulation of 137Cs and 90Sr by six spring wheat varieties. Radiat Environ Biophys 44:289–298
Bjornstad HE, Lien HN, Fuyu Y, Salbu B (1992) Determination of 90Sr in environmental and biological materials with combined HDEHP solvent extraction-low liquid scintillation counting technique. J Radioanal Nucl Chem 156(1):165–173
Kuleva YD, Polikarpova GG, Prigodeyb EV, Assimakopoulos PA (1994) Strontium-90 concentrations in human teeth in South Ukraine, 5 years after the Chernobyl accident. Sci Total Environ 155(3):215–219
Kozheurov VP, Degteva M (1994) Dietary intake evaluation and dosimetric modelling for the Techa River residents based on in vivo measurements of strontium-90 in teeth and skeleton. Sci Total Environ 142(1–2):63–72
Stamoulis KC, Assimakopoulos PA, Ioannides KG, Johnson E, Soucacos PN (1994) Strontium-90 concentration measurements in human bones and teeth in Greece. Sci Total Environ 229(3):165–182
Tanaka K, Endo S, Ivannikov A, Toyoda S, Tieliewuhan E, Zhumadilov K, Miyazawa C, Suga S, Kitagawa K, Hoshi M (2006) Study on influence of X-ray baggage scan on ESR dosimetry for SNTS using human tooth enamel. J Radiat Res 47:A81–A83
Toyoda S, Imata H, Romanyukha A, Hoshi M (2006) Toward high sensitivity ESR dosimetry of mammal teeth: the effect of chemical treatment. J Radiat Res 47:A71–A74
Ivannikov A, Zhumadilov K, Tieliewhan E, Apsalikov K, Jiao L, Apsalikov K, Berekenova G, Zhumadilov Z, Toyoda S, Miyazawa C, Skvortsov V, Stepanenko V, Hoshi M (2006) Radiation dose reconstruction by tooth enamel EPR dosimetry for population of Dolon and Mostik settlements placed in vicinity of the radioactive fallout trace of the most contaminating nuclear test in the Semipalatinsk nuclear test site. J Radiat Res 47:A39–A46
Zhumadilov K, Ivannikov A, Skvortshov V, Stepanenko V, Zhumadilov Z, Endo S, Tanaka K, Hoshi M (2005) Tooth enamel EPR dosimetry: optimization of EPR spectra recording parameters and effect of sample mass on spectral sensitivity. J Radiat Res 46:435–442
Romanyukha AA, Mitch MG, Lin Z, Nagy V, Coursey BM (2002) Mapping the distribution of 90Sr in teeth with a photostimulable phosphor imaging detector. Radiat Res 157:341–349
Miyahara J (1989) The imaging plate: a new radiation image sensor. Chem Today 223:29–36
Simon L, Baverstock F, Lindholm C (2003) A summary of evidence on radiation exposures received near to the Semipalatinsk nuclear weapons test site in Kazakhstan. Health Phys 84:718–725
Tieliewuhan E, Tanaka K, Toyoda S, Kadoma A, Endo S, Romanyukha A, Tarasov O, Hoshi M (2006) 90Sr concentration in cow teeth from south Ural region, Russia, using Monte Carlo simulation. J Radiat Res 47:A117–A120
Fermi E, Physik Z (1934) In: Kabir PK (ed) The development of weak interaction theory. Gordon & Breach, New York, pp 88
Transport Methods Group in Los Alamos National Laboratory (1997) TSICC computer code collection MCNP4B Monte Carlo N-Particle Transport Code system CCC-660
Mori K, Hamaoka T (1994) Imaging plate-autoradiography system (BAS). Proteins Nucleic Enzymes 39(11):1877–1887
Acknowledgments
Part of the present study was supported by Grant-in-Aid for Scientific Research from the Japan Society for the Promotion of Science under grant #15406002 and #17406001, awarded to Prof M. Hoshi, Hiroshima University. The authors express their sincere appreciation to Mr. Kazuhide Kitagawa, Mr. Shinji Suga, and Mr. Shingo Sasatani, Hiroshima University, for their support in the experiment using imaging plate, and to Mr. Takahisa Yamane of Fujifilm Co. Ltd for his support in the Monte Carlo calculations.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Tanaka, K., Endo, S., Toyoda, S. et al. Monte Carlo-based calculation of imaging plate response to 90Sr in teeth: experimental validation of the required correction on sample thickness. Radiat Environ Biophys 46, 215–220 (2007). https://doi.org/10.1007/s00411-007-0102-7
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00411-007-0102-7