Abstract
Bronchopleural (BPF) and alveolar-pleural (APF) fistulas are frequently encountered in clinical practice with persistent air leaks that can lead to significant morbidity, prolonged hospital stay, and potentially increased mortality. BPF and APF are commonly related to pulmonary resections. Other etiologies include minimally invasive procedures (thoracentesis and image-guided biopsies), and spontaneous fistulas related to an underlying structural lung disease (e.g., emphysema) or a necrotizing pulmonary process (e.g., infection or malignancy). Radiofrequency ablation for pulmonary malignancies is an effective modality that can rarely lead to APF with persistent air leak. Surgical intervention remains the standard treatment option for BPF and APF. A variety of minimally invasive bronchoscopic approaches can be considered for selected nonsurgical candidates. The use of one-way endobronchial valves to manage severe and persistent air leaks can be considered a minimally invasive option in selected patients. The valves selectively block inspiratory airflow to a specific segmental or subsegmental airway but allow expiratory flow with drainage of air and secretions from the corresponding distal airways and lung parenchyma.
References
Cefolio RJ (2005) Recent advances in the treatment of air leaks. Curr Opin Pulm Med 11:319–323
Wood DE, McKenna RJ, Yusen RD et al (2007) A multicenter trial of an intrabronchial valve for treatment of severe emphysema. J Thorac Cardiovasc Surg 133:65–73
Lois M, Noppen M (2005) Bronchopleural fistulas: an overview of the problem with special focus on endoscopic management. Chest 128:3955–3965
Mitchell KM, Boley TM, Hazelrigg SR (2006) Endobronchial valves for treatment of bronchopleural fistula. Ann Thorac Surg 81:1129–1131
Ricci ZJ, Haramati LB, Rosenbaum AT et al (2002) Role of computed tomography in guiding the management of peripheral bronchopleural fistula. J Thorac Imaging 17:214–218
Alifano M, Sepulveda S, Mulot A et al (2003) A new method for detection of post-pneumonectomy broncho-pleural fistulas. Ann Thorac Surg 75:1662–1664
Lois M, Noppen M (2005) Bronchopleural fistulas: an overview of the problem with special focus on endoscopic management. Chest 128(6):3955–3965
Dupuy DE, Zagoria RJ, Akerley W, Mayo-Smith WW, Kavanagh PV, Safran H (2000) Percutaneous radiofrequency ablation of malignancies in the lung. AJR Am J Roentgenol 174(1):57–59
Matsuoka T, Okuma T (2007) CT-guided radiofrequency ablation for lung cancer. Int J Clin Oncol 12:71–78
Sakurai J, Hiraki T, Mukai T et al (2007) Intractable pneumothorax due to bronchopleural fistula after radiofrequency ablation of lung tumors. J Vasc Interv Radiol 18:141–145
Clasen S, Kettenbach J, Kosan B et al (2009) Delayed development of pneumothorax after pulmonary radiofrequency ablation. Cardiovasc Intervent Radiol 32:484–490
Snell GI, Holsworth L, Fowler S et al (2005) Occlusion of a broncho-cutaneous fistula with endobronchial one-way valves. Ann Thorac Surg 80:1930–1932
Singh SS, Pyragius MD, Shah PJ et al (2007) Management of a large bronchopleural fistula using a tracheobronchial stent. Heart Lung Circ 16:57–59
Takaoka K, Inoue S, Ohira S (2002) Central bronchopleural fistulas closed by bronchoscopic injection of absolute ethanol. Chest 122:374–378
Onotera RT, Unruh HW (1988) Closure of post-pneumonectomy bronchopleural fistula with fibrin sealant (Tisseel). Thorax 43:1015–1016
Ponn RB, D’Agostino RS, Stern H et al (1993) Treatment of peripheral bronchopleural fistulas with endobronchial occlusion coils. Ann Thorac Surg 56:1343–1347
Weinreb N, Riker D, Beamis J et al (2009) Ease of use of watanabe spigot for alveolopleural fistulas. J Bronchol Intervent Pulmonol 16:130–132
Feller-Kopman D, Bechara R, Garland R et al (2006) Use of removable endobronchial valve for the treatment of bronchopleural fistula. Chest 130:273–275
Anile M, Venuta F, De Giacomo T et al (2006) Treatment of persistent air leakage with endobronchial one-way valves. J Thorac Cardiovasc Surg 132:711–712
Travaline JM, McKenna RJ Jr, DeGiacomo T et al (2009) Treatment of persistent pulmonary air leaks using endobronchial valves. Chest 136(2):355–360
Fann JI, Berry GJ, Burdon TA (2006) The use of endobronchial valve device to eliminate air leak. Respir Med 100:1402–1406
Springmeyer SC, Bolliger CT, Waddell TK, Gonzalez X, Wood DE, IBV Valve Pilot Trials Research Teams (2009) Treatment of heterogeneous emphysema using the Spiration IBV Valves. Thorac Surg Clin 19(2):247–253
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Abu-Hijleh, M., Blundin, M. Emergency Use of an Endobronchial One-Way Valve in the Management of Severe Air Leak and Massive Subcutaneous Emphysema. Lung 188, 253–257 (2010). https://doi.org/10.1007/s00408-009-9204-0
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00408-009-9204-0