Skip to main content

Advertisement

Log in

Light and electron microscopic study of stress-shielding effects on rat patellar tendon

  • Original Article
  • Published:
Archives of Orthopaedic and Trauma Surgery Aims and scope Submit manuscript

Abstract

In this second part of our study, the histomorphologic changes occurring in the patellar tendon (PT) of rats after sole stress-shielding were evaluated. In seven adult albino rats, both PTs were exposed by straight skin incision and then stress-shielded on one side by a cerclage, while the contralateral PT served as the sham-operated control. One animal died after the operation and was used as a negative control. After 10 weeks of otherwise unrestricted motion, the rats were killed, and the histomorphology of all PT specimen pairs compared by light and transmission electron microscopy. Light microscopy showed mid-portion thickening and irregularity of collagen bundles in the stress-shielded tendons. Intense remodelling was demonstrated by increased cellularity and vascularity, as well as by enrichment in acidic proteoglycans. Ultrastructural evaluation and morphometry revealed a predominance of large diameter (peak between 180 and 260 nm) collagen fibrils in the sham-operated controls, while in the stress-shielded tendons the number of apparently new, small-diameter (peak between 40 and 60 nm) collagen fibrils increased (up to 77% per cross-sectional field of view). The difference in peak diameters was statistically significant (p < 0.0005). This rat model demonstrated that sole stress-shielding not only causes biomechanical alterations, but also intense tissue remodelling and significant morphological changes in the collagen fibrils in the patellar tendon, comparable to so-called ‘ligamentization’ in experimental and clinical patellar tendon grafts for anterior cruciate ligament reconstruction.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received: 30 June 2000

Rights and permissions

Reprints and permissions

About this article

Cite this article

Muellner, T., Kwasny, O., Loehnert, V. et al. Light and electron microscopic study of stress-shielding effects on rat patellar tendon. Arch Orth Traum Surg 121, 561–565 (2001). https://doi.org/10.1007/s004020100281

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s004020100281

Navigation