Abstract
A total of 1202 fractures of the ankle were treated with absorbable implants made of polyglycolide/ polylactide copolymer or self-reinforced polyglycolide and/or self-reinforced polylactide between November 5, 1984, and January 12, 1994. A redisplacement after fixation was diagnosed in 30 patients (2.5%). The redisplacement occurred in 8 of 934 (0.9%) simple ankle fractures and in 22 of 268 (8.2%) severer ankle fractures. A breakage or loosening of the absorbable implant was verified at reoperation in 8 cases and was suspected in another 9. A technical failure was the main reason in 13 cases. A reoperation was performed for 25 patients. The absorbable implants seem to provide a secure fixation in the majority of ankle fractures, but the use of these implants showed unsatisfactory results in unstable and comminuted fractures.
Similar content being viewed by others
Author information
Authors and Affiliations
Additional information
Received: 26 August 1996
Rights and permissions
About this article
Cite this article
Pelto-Vasenius, K., Hirvensalo, E., Vasenius, J. et al. Redisplacement after ankle osteosynthesis with absorbable implants. Arch Orth Traum Surg 117, 159–162 (1998). https://doi.org/10.1007/s004020050218