Abstract
Introduction
Distal radius fractures (DRF) are the most common fractures of the upper extremities. The incidence is expected to continue rising in the next years due to the increased life expectancy. Palmar locking plate stabilizing has since become the standard treatment for dorsally displaced DRF with a complication rate of 8–39% reported in the literature. Main aim of this study was to investigate the incidence of complications after DRF stabilization using palmar angular stable locking plate.
Methods
A retrospective medical records review conducted from January 2013 to December 2016 included a total of 392 patients with DRF, that were stabilized using palmar angular stable locking plate and showed a minimum follow-up of 3 months. The group comprised 259 female and 133 male patients with a mean follow-up interval of 11 months (range 3–52 months). All recorded complications were documented. Range of motion (ROM) in extension, flexion, supination, pronation, radial- and ulnar deviation of the last follow-up was noted. Age was divided into younger than 65 years (< 65 years) and older than 65 years (≥ 65 years). The primary, immediate postoperative and final checkup radiographs were scrutinized for alignment and intra-articular step-off.
Results
A total of 51 (13%) early and 17 late (4%) complications were recorded in 392 patients. The most common complications included carpal tunnel syndrome (3%), complex regional pain syndrome (3%) and loss of reduction (2%). Of the 68 complications, only 25 (6%) were directly related to the plate. 73% of all complications occurred in AO type C fractures. Patients without complications showed a significantly better ROM in extension, flexion, pronation and supination than patients with complications. No significant differences in incidence of complications, ROM or loss of reduction could be found between patients over and under 65 years of age. Gender and type of immobilization showed no significant influence on the complication rate.
Conclusions
Stabilization of DRF by palmar angular stable locking plate is a safe form of treatment. In the majority of the cases a good clinical and radiological outcome with no complications was documented. Gender and type of immobilization had no impact on the complication rate and an age over 65 years is not associated with an increased risk for complications or restricted ROM.
Similar content being viewed by others
References
MacIntyre NJ, Dewan N (2016) Epidemiology of distal radius fractures and factors predicting risk and prognosis. J Hand Ther 29:136–145. https://doi.org/10.1016/j.jht.2016.03.003
Quadlbauer S, Leixnering M, Jurkowitsch J et al (2017) Volar radioscapholunate arthrodesis and distal scaphoidectomy after malunited distal radius fractures. J Hand Surg Am 42:754.e1–754.e8. https://doi.org/10.1016/j.jhsa.2017.05.031
Schermann H, Kadar A, Dolkart O et al (2018) Repeated closed reduction attempts of distal radius fractures in the emergency department. Arch Orthop Trauma Surg 138:591–596. https://doi.org/10.1007/s00402-018-2904-2
Weil NL, El Moumni M, Rubinstein SM et al (2017) Routine follow-up radiographs for distal radius fractures are seldom clinically substantiated. Arch Orthop Trauma Surg 137:1187–1191. https://doi.org/10.1007/s00402-017-2743-6
Quadlbauer S, Pezzei C, Hintringer W et al (2018) Clinical examination of the distal radioulnar joint. Orthopade 47:628–636. https://doi.org/10.1007/s00132-018-3584-x
Wilcke MKT, Hammarberg H, Adolphson PY (2013) Epidemiology and changed surgical treatment methods for fractures of the distal radius: a registry analysis of 42,583 patients in Stockholm County, Sweden, 2004–2010. Acta Orthop 84:292–296. https://doi.org/10.3109/17453674.2013.792035
Court-Brown CM, Caesar B (2006) Epidemiology of adult fractures: a review. Injury 37:691–697. https://doi.org/10.1016/j.injury.2006.04.130
Figl M, Weninger P, Liska M et al (2009) Volar fixed-angle plate osteosynthesis of unstable distal radius fractures: 12 months results. Arch Orthop Trauma Surg 129:661–669. https://doi.org/10.1007/s00402-009-0830-z
Figl M, Weninger P, Jurkowitsch J et al (2010) Unstable distal radius fractures in the elderly ratient-volar fixed-angle plate osteosynthesis prevents secondary loss of reduction. J Trauma Inj Infect Crit Care 68:992–998. https://doi.org/10.1097/TA.0b013e3181b99f71
Zong S, Le, Kan SL, Su LX, Wang B (2015) Meta-analysis for dorsally displaced distal radius fracture fixation: Volar locking plate versus percutaneous Kirschner wires. J Orthop Surg Res doi. https://doi.org/10.1186/s13018-015-0252-2
Wei DH, Raizman NM, Bottino CJ et al (2009) Unstable distal radial fractures treated with external fixation, a radial column plate, or a volar plate: a prospective randomized trial. J Bone Jt Surg Ser A 91:1568–1577. https://doi.org/10.2106/JBJS.H.00722
Schnetzke M, Fuchs J, Vetter SY et al (2018) Intraoperative three-dimensional imaging in the treatment of distal radius fractures. Arch Orthop Trauma Surg 138:487–493. https://doi.org/10.1007/s00402-018-2867-3
Quadlbauer S, Pezzei C, Jurkowitsch J et al (2016) Early rehabilitation of distal radius fractures stabilized by volar locking plate: a prospective randomized pilot study. J Wrist Surg 06:102–112. https://doi.org/10.1055/s-0036-1587317
Lameijer CM, ten Duis HJ, van Dusseldorp I et al (2017) Prevalence of posttraumatic arthritis and the association with outcome measures following distal radius fractures in non-osteoporotic patients: a systematic review. Arch Orthop Trauma Surg 137:1499–1513. https://doi.org/10.1007/s00402-017-2765-0
Arora R, Lutz M, Deml C et al (2011) A prospective randomized trial comparing nonoperative treatment with volar locking plate fixation for displaced and unstable distal radial fractures in patients sixty-five years of age and older. J Bone Jt Surg AmVol 93:2146–2153. https://doi.org/10.2106/JBJS.J.01597
Arora R, Lutz M, Hennerbichler A et al (2007) Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate. J Orthop Trauma 21:316–322. https://doi.org/10.1097/BOT.0b013e318059b993
Haug LCP, Deml C, Blauth M, Arora R (2011) Dorsal screw penetration following implant removal after volar locked plating of distal radius fracture. Arch Orthop Trauma Surg 131:1279–1282. https://doi.org/10.1007/s00402-011-1300-y
Erhart S, Toth S, Kaiser P et al (2018) Comparison of volarly and dorsally displaced distal radius fracture treated by volar locking plate fixation. Arch Orthop Trauma Surg 138:879–885. https://doi.org/10.1007/s00402-018-2925-x
Esenwein P, Sonderegger J, Gruenert J et al (2013) Complications following palmar plate fixation of distal radius fractures: a review of 665 cases. Arch Orthop Trauma Surg 133:1155–1162. https://doi.org/10.1007/s00402-013-1766-x
Quadlbauer S, Pezzei C, Jurkowitsch J et al (2017) Spontaneous radioscapholunate fusion after septic arthritis of the wrist: a case report. Arch Orthop Trauma Surg 137:579–584. https://doi.org/10.1007/s00402-017-2659-1
Wichlas F, Haas NP, Disch A et al (2014) Complication rates and reduction potential of palmar versus dorsal locking plate osteosynthesis for the treatment of distal radius fractures. J Orthop Traumatol 15:259–264. https://doi.org/10.1007/s10195-014-0306-y
Hohendorff B, Knappwerth C, Franke J et al (2018) Pronator quadratus repair with a part of the brachioradialis muscle insertion in volar plate fixation of distal radius fractures: a prospective randomised trial. Arch Orthop Trauma Surg 138:1479–1485. https://doi.org/10.1007/s00402-018-2999-5
World Health Organization (1972) Psychogeriatrics. Report of a WHO scientific group. World Health Organ Tech Rep Ser 507:1–48
Onwuchekwa AC, Asekomeh EGspower (2009) Geriatric admissions in a developing country: experience from a tertiary centre in Nigeria. Ethn Dis 19:359–362
Veldman PH, Reynen HM, Arntz IE, Goris RJ (1993) Signs and symptoms of reflex sympathetic dystrophy: prospective study of 829 patients. Lancet 342:1012–1016
Müller ME, Nazarian S, Koch P, Schatzker J (1990) Tibia/Fibula = 4. In: The comprehensive classification of fractures of long bones. Springer, Berlin, Heidelberg, pp 148–191
Schmitt R, Pommersberger K (2014) Karpale Funktion und Morphometerie. In: Schmitt R, Lanz U (eds) Bildgeb. Diagnostik der Hand, 3rd edn. Thieme, Stuttgart, pp 184–197
Soong M, Earp BE, Bishop G et al (2011) Volar locking plate implant prominence and flexor tendon rupture. J Bone Jt Surg Ser A 93:328–335. https://doi.org/10.2106/JBJS.J.00193
Cohen J (1988) Differences between correlation coefficients. In: Cohen J (ed) Stat. Power Anal. Behav. Sci, 2nd edn. Lawrence Erlbaum Associates, Mahwah, pp 109–145
Thorninger R, Madsen ML, Wæver D et al (2017) Complications of volar locking plating of distal radius fractures in 576 patients with 3.2 years follow-up. Injury 48:1104–1109. https://doi.org/10.1016/j.injury.2017.03.008
Unglaub F, Langer MF, Hohendorff B et al (2017) Distale Radiusfraktur. Orthopade 46:93–110. https://doi.org/10.1007/s00132-016-3347-5
Koh S, Morris RP, Patterson RM et al (2006) Volar fixation for dorsally angulated extra-articular fractures of the distal radius: a biomechanical study. J Hand Surg Am 31:771–779. https://doi.org/10.1016/j.jhsa.2006.02.015
Lutz M, Erhart S, Deml C, Klestil T (2016) Arthroskopisch gesteuerte Osteosynthese der dislozierten intraartikulären distalen Radiusfraktur. Oper Orthop Traumatol 28:279–290. https://doi.org/10.1007/s00064-016-0448-6
Pillukat T, Fuhrmann R, Windolf J, van Schoonhoven J (2016) Die palmare winkelstabile Plattenosteosynthese bei Extensionsfrakturen des distalen Radius. Oper Orthop Traumatol 28:47–64. https://doi.org/10.1007/s00064-015-0433-5
Peng F, Liu YX, Wan ZY (2018) Percutaneous pinning versus volar locking plate internal fixation for unstable distal radius fractures: a meta-analysis. J Hand Surg Eur Vol 43:158–167. https://doi.org/10.1177/1753193417735810
Zhang LH, Wang YN, Zhi M et al (2015) Volar locking plate versus external fixation for the treatment of unstable distal radial fractures: a meta-analysis of randomized controlled trials. J Surg Res 193:324–333. https://doi.org/10.1016/j.jss.2014.06.018
Diwersi N, Babst R, Link B-C (2016) [Miniplates as augmentation implants in osteosynthesis of complex distal radial fractures. Oper Orthop Traumatol 28:402–406. https://doi.org/10.1007/s00064-016-0469-1
Orbay JL, Fernandez DL (2002) Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report. J Hand Surg Am 27:205–215. https://doi.org/10.1053/jhsu.2002.32081
Orbay JL, Fernandez DL (2004) Volar fixed-angle plate fixation for unstable distal radius fractures in the elderly patient. J Hand Surg Am 29:96–102. https://doi.org/10.1016/j.jhsa.2003.09.015
Ward CM, Kuhl TL, Adams BD (2011) Early complications of volar plating of distal radius fractures and their relationship to surgeon experience. Hand 6:185–189. https://doi.org/10.1007/s11552-010-9313-5
Drobetz H, Kutscha-Lissberg E (2003) Osteosynthesis of distal radial fractures with a volar locking screw plate system. Int Orthop 27:1–6. https://doi.org/10.1007/s00264-002-0393-x
Rozental TD, Blazar PE, Franko OI et al (2009) Functional outcomes for unstable distal radial fractures treated with open reduction and internal fixation or closed reduction and percutaneous fixation. J Bone Jt Surg Am Vol 91:1837–1846. https://doi.org/10.2106/JBJS.H.01478
Zettl RP, Clauberg E, Nast-Kolb D et al (2009) Volare winkelstabile vs. dorsale Plattenosteosynthese bei der distalen Radiusextensionsfraktur: Eine prospektive, randomisierte Untersuchung. Unfallchirurg 112:712–718. https://doi.org/10.1007/s00113-008-1526-5
Rampoldi M, Marsico S (2007) Complications of volar plating of distal radius fractures. Acta Orthop Belg 73:714–719. https://doi.org/10.1016/j.jhsa.2014.03.038
Soong M, Van Leerdam R, Guitton TG et al (2011) Fracture of the distal radius: risk factors for complications after locked volar plate fixation. J Hand Surg Am 36:3–9. https://doi.org/10.1016/j.jhsa.2010.09.033
Bentohami A, De Burlet K, De Korte N et al (2014) Complications following volar locking plate fixation for distal radial fractures: a systematic review. J Hand Surg Eur Vol 39:745–754. https://doi.org/10.1177/1753193413511936
Roh YH, Lee BK, Noh JH et al (2014) Factors associated with complex regional pain syndrome type I in patients with surgically treated distal radius fracture. Arch Orthop Trauma Surg 134:1775–1781. https://doi.org/10.1007/s00402-014-2094-5
Üçeyler N, Eberle T, Rolke R et al (2007) Differential expression patterns of cytokines in complex regional pain syndrome. Pain 132:195–205. https://doi.org/10.1016/j.pain.2007.07.031
Nickel FT, Maihöfner C (2010) Aktuelle Erkenntnisse zur Pathophysiologie des CRPS I. Handchirurgie, Mikrochirurgie, Plast Chir Organ der Deutschsprachigen Arbeitsgemeinschaft für Handchirurgie Organ der Deutschsprachigen Arbeitsgemeinschaft für Mikrochirurgie der Peripher Nerven und Gefässe. Organ der Vereinigung der Deut 42:8–14. https://doi.org/10.1055/s-0029-1246211
Tanl ECT, Janssenl AJM, Roestenbergl P et al (2011) Mitochondrial dysfunction in muscle tissue of complex regional pain syndrome type I patients. Eur J Pain 15:708–715. https://doi.org/10.1016/j.ejpain.2010.12.003
Zollinger PE, Tuinebreijer WE, Breederveld RS, Kreis RW (2007) Can vitamin C prevent complex regional pain syndrome in patients with wrist fractures? A randomized, controlled, multicenter dose-response study. J Bone Jt Surg Ser A 89:1424–1431. https://doi.org/10.2106/JBJS.F.01147
Spies CK, Langer M, Müller LP et al (2018) Anatomie und Biomechanik des distalen Radioulnargelenks. Orthopade 47:621–627. https://doi.org/10.1007/s00132-018-3589-5
Gabl M, Arora R, Klauser AS, Schmidle G (2016) Characteristics of secondary arthrofibrosis after intra-articular distal radius fracture. Arch Orthop Trauma Surg 136:1181–1188. https://doi.org/10.1007/s00402-016-2490-0
Spies CK, Langer M, Hahn P et al (2018) The treatment of primary arthritis of the finger and thumb joint. Dtsch Aerzteblatt Online 115:269–275. https://doi.org/10.3238/arztebl.2018.0269
Köhler S, Koch K, Arsalan-Werner A, et al (2017) Wrist arthrodesis with a fixed-angle,”low-profile” fusion plate without carpometacarpal joint fixation. Oper Orthop Traumatol 29:416–430. https://doi.org/10.1007/s00064-017-0517-5
Benson EC, DeCarvalho A, Mikola EA et al (2006) Two potential causes of EPL rupture after distal radius volar plate fixation. Clin Orthop Relat Res 451:218–222. https://doi.org/10.1097/01.blo.0000223998.02765.0d
Kumar D, Breakwell L, Deshmukh SC, Singh BK (2001) Tangential views of the articular surface of the distal radius—aid to open reduction and internal fixation of fractures. Injury 32:783–786
Herisson O, Delaroche C, Maillot-Roy S et al (2017) Comparison of lateral and skyline fluoroscopic views for detection of prominent screws in distal radius fractures plating: results of an ultrasonographic study. Arch Orthop Trauma Surg 137:1357–1362. https://doi.org/10.1007/s00402-017-2759-y
Orbay JL, Touhami A (2006) Current concepts in volar fixed-angle fixation of unstable distal radius fractures. Clin Orthop Relat Res 445:58–67
Chen Y, Chen X, Li Z et al (2016) Safety and efficacy of operative versus nonsurgical management of distal radius fractures in elderly patients: a systematic review and meta-analysis. J Hand Surg Am 41:404–413. https://doi.org/10.1016/j.jhsa.2015.12.008
Diaz-Garcia RJ, Oda T, Shauver MJ, Chung KC (2011) A systematic review of outcomes and complications of treating unstable distal radius fractures in the elderly. J Hand Surg Am 36:824–835. https://doi.org/10.1016/j.jhsa.2011.02.005
Lee JI, Park KC, Joo I-H et al (2018) The Effect of osteoporosis on the outcomes after volar locking plate fixation in female patients older than 50 years with unstable distal radius fractures. J Hand Surg Am 43:731–737. https://doi.org/10.1016/j.jhsa.2018.05.028
Daneshvar P, Chan R, Macdermid J, Grewal R (2014) The effects of ulnar styloid fractures on patients sustaining distal radius fractures. J Hand Surg Am 39:1915–1920. https://doi.org/10.1016/j.jhsa.2014.05.032
Acknowledgements
We thank Rose-Marie Sedlacek for proof reading this article. Without her help, this English publication would not have been possible.
Funding
This research received no specific grant from any funding agency in the public, commercial, or not-for-profit sectors.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors, their immediate families, and any research foundations with which they are affiliated have not received any financial payments or other benefits from any commercial entity related to the subject of this article.
Ethical approval
All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards. Institutional review board approval was obtained for this study
Electronic supplementary material
Below is the link to the electronic supplementary material.
Rights and permissions
About this article
Cite this article
Quadlbauer, S., Pezzei, C., Jurkowitsch, J. et al. Early complications and radiological outcome after distal radius fractures stabilized by volar angular stable locking plate. Arch Orthop Trauma Surg 138, 1773–1782 (2018). https://doi.org/10.1007/s00402-018-3051-5
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00402-018-3051-5