Abstract
The incidence of proximal humeral fractures increases. The locking plate osteosynthesis is a standard procedure to treat displaced proximal humeral fractures. In the mostly affected elderly patients with an osteoporotic bone structure, complication rate is still high. An implant removal is commonly required. But also younger patients often request for hardware removal. The open implant removal with a subacromial and subdeltoideal arthrolysis is an extensive secondary surgery for the patients. We present a new technique to remove a locking plate from the proximal humerus arthroscopically with all advantages of the minimally invasive surgery, and the possibility to treat concomitant intraarticular pathologies parallelly.
Similar content being viewed by others
References
Agudelo J, Schürmann M, Stahel P, Helwig P, Morgan SJ, Zechel W et al (2007) Analysis of efficacy and failure in proximal humerus fractures treated with locking plates. J Orthop Trauma 21(10):676–681. doi:10.1097/BOT.0b013e31815bb09d
Fankhauser F, Boldin C, Schippinger G, Haunschmid C, Szyszkowitz R (2005) A locking plate for unstable fractures of the proximal humerus. Clin Orthop Relat Res 430:176–181. doi:10.1097/01.blo.0000137554.91189.a9
Gallo RA, Sciulli R, Daffner RH, Altman DT, Altman GT (2007) Defining the relationship between rotator cuff injury and proximal humerus fractures. Clin Orthop Relat Res 458:70–77
Kannus P, Palvanen M, Niemi S, Parkkari J, Järvinen M, Vuori I (2000) Osteoporotic fractures of the proximal humerus in elderly Finnish persons: sharp increase in 1970–1998 and alarming projections for the new millennium. Acta Orthop Scand 71(5):465–470. doi:10.1080/000164700317381144
Kettler M, Biberthaler P, Braunstein V, Zeiler C, Kroetz M, Mutschler W (2006) Treatment of proximal humeral fractures with the PHILOS angular stable plate. Presentation of 225 cases of dislocated fractures. Unfallchirurg 109(12):1032–1040. doi:10.1007/s00113-006-1165-7
Kirchhoff C, Braunstein V, Kirchhoff S, Sprecher CM, Ockert B, Fischer F et al (2008) Outcome analysis following removal of locking plate fixation of the proximal humerus. BMC Musculoskelet Disord 9:138. doi:10.1186/1471-2474-9-138
Nho SJ, Brophy RH, Barker JU, Cornell CN, MacGillivray JD (2007) Management of proximal humeral fractures based on current literature. J Bone Joint Surg Am 89(Suppl 3):44–58. doi:10.2106/JBJS.G.00648
Owsley KC, Gorczyca JT (2008) Fracture displacement and screw cutout after open reduction and locked plate fixation of proximal humeral fractures. J Bone Joint Surg Am 90(2):233–240. doi:10.2106/JBJS.F.01351
Röderer G, Abouelsoud M, Gebhard F, Böckers TM, Kinzl L (2007) Minimally invasive application of the non-contact-bridging (NCB) plate to the proximal humerus: an anatomical study. J Orthop Trauma 21(9):621–627. doi:10.1097/BOT.0b013e318157f0cd
Südkamp N, Bayer J, Hepp P, Voigt C, Oestern H, Kaab M, Luo C, Plecko M, Wendt K, Kostler W, Konrad G (2009) Open reduction and internal fixation of proximal humeral fractures using the locking proximal humerus plate—results of a prospective multicenter observational study. J Bone Joint Surg Am (accepted)
Taverna E, Sansone V, Battistella F (2004) Arthroscopic treatment for greater tuberosity fractures: rationale and surgical technique. Arthroscopy 20(6):e53–e57. doi:10.1016/j.arthro.2004.04.072
Voigt C, Woltmann A, Partenheimer A, Lill H (2007). Management of complications after angularly stable locking proximal humerus plate fixation. Chirurg 78(1):40–46. doi:10.1007/s00104-006-1241-0
Conflict of interest statement
There is no conflict of interest.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Voigt, C., Geisler, A. & Lill, H. Arthroscopic locking plate removal after proximal humeral fractures. Arch Orthop Trauma Surg 130, 391–395 (2010). https://doi.org/10.1007/s00402-009-0882-0
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00402-009-0882-0