Skip to main content

Advertisement

Log in

The effect of patient position on blood loss in primary cemented total hip arthroplasty

  • Orthopaedic Surgery
  • Published:
Archives of Orthopaedic and Trauma Surgery Aims and scope Submit manuscript

Abstract

Introduction

The total blood loss of 101 cemented primary total hip arthroplasties was studied in a prospective randomised study.

Materials and method

Fifty of them were implanted in the supine position and 51 in the lateral position. The patients were matched for sex, height, weight and ASA grade. Only one surgeon carried out the operations using the same operative technique and identical prosthesis in both groups.

Results

The intraoperative blood loss associated with the supine position was 1,156 ml (954–1,265 ml) and 1,129 ml (989–1,310 ml) in the lateral position. There was no difference when comparing the two groups (P = 0.41).

Conclusion

Patient positioning in supine or lateral during total hip arthroplasty surgery has no bearing on the total amount of blood loss.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Chin S, Abon-Madi MN, Eurin B, Witovet J, Montagne J (1982) Blood loss in total hip replacement: extradural versus phenoperidine analgesia. Br J Anaesth 54:491–495

    Article  PubMed  CAS  Google Scholar 

  2. Fredin H, Gustafsson C, Rosberg B (1984) Hypotensive analgesia, thromboprophylaxis and post-operative thromboembolism in total hip replacement. Acta Anaesthesiol Scad 28:16–19

    Google Scholar 

  3. Axelrod FB, Pepkowitz SH, Goldfinger D (1989) Establishment of a schedule of optimal pre-operative collection of autologous blood. Transfusion 29:677–680

    Article  PubMed  CAS  Google Scholar 

  4. Gombotz H, Rehak P (2000) Preoperative treatment with recombinant human erythropoietin or predeposit of autologous blood in women undergoing primary hip replacement. Acta Anaesthesiol Scand 44(6):737–742

    Article  PubMed  CAS  Google Scholar 

  5. Claeys MA, Vermeersch N (2007) Reduction of blood loss with tranexamic acid in primary total hip replacement surgery. Acta Chir Belg 107(4):397–401

    PubMed  CAS  Google Scholar 

  6. Carlsson O, Schott U (2000) Tranexamic acid reduces blood loss in total hip replacement surgery. Anesth Analg 91(5):1124–1130

    Article  PubMed  Google Scholar 

  7. Leikola J (1988) Transfusion transmitted infectious agents, excluding hepatitis and immunodeficiency viruses. Acta Anaesthesiol Scad 32(Supplement 89):20–25

    Google Scholar 

  8. Grillner L (1988) Transfusion transmitted human T-lymphotropic virus infections. Acta Anaesthesiol Scad 32(Supplement 89):19–29

    Google Scholar 

  9. Hardinge K (1982) The direct lateral approach to the hip. J Bone Joint Surg [Br] 64:17–19

    CAS  Google Scholar 

  10. Nadler SB, Hidalgo JU, Bloch T (1962) Prediction of blood volume in normal adults. Surgery 51:224–232

    Google Scholar 

  11. Trice ME, Walker RH (1999) Blood loss and transfusion rate in noncemented and cemented/hybrid total hip arthroplasty. Is there a difference? A comparison of 25 matched pairs. Orthopedics 22(1 Suppl):s141–s144

    PubMed  CAS  Google Scholar 

  12. Hoefnagals EM, Anderson PG (2007) Sonography after total hip replacement: reproducibility and normal values in 47 clinically uncomplicated cases. Acta Orthop 78(1):81

    Article  Google Scholar 

  13. Parrini L, Parrini M (1988) Ultrasound examination of haematomas after total hip replacement. Int Orthop 12(1):79–82

    Article  PubMed  CAS  Google Scholar 

  14. Itaml Y, Akamatsu N, Tomita Y, Nagai N, Nakajima I (1983) A clinical study of the results of cementless total hip replacement. Arch Orthop Trauma Surg 102:1–10

    Article  Google Scholar 

  15. Widman J, Isacson J (2001) Lateral position reduces the blood loss in hip replacement surgery. A prospective randomised study of 74 patients. Int Orthopaed 25:226–227

    Article  CAS  Google Scholar 

  16. Schneeberger AG, Schulz RF, Ganz R (1998) Blood loss in total hip arthroplasty. Lateral position combined with preservation of capsule versus supine position combined with capsulectomy. Ach Orthop Trauma Surg 117:47–49

    Article  CAS  Google Scholar 

  17. Locher S, Kuhna R (1999) Blood loss in total hip prosthesis implantation-lateral versus supine position. Z Orthop Ihre Grenzgek 137(2):148–152

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Alistair Pace.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Pace, A., Yousef, A. The effect of patient position on blood loss in primary cemented total hip arthroplasty. Arch Orthop Trauma Surg 128, 1209–1212 (2008). https://doi.org/10.1007/s00402-008-0579-9

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00402-008-0579-9

Keywords

Navigation