Skip to main content

Advertisement

Log in

The fixation strength of hydroxyapatite-coated Schanz screws and standard stainless steel Schanz screws in lower extremity lengthening

A comparison based on a new torque value index: the fixation index

  • Original Article
  • Published:
Archives of Orthopaedic and Trauma Surgery Aims and scope Submit manuscript

Abstract

Introduction: Lengthening procedures are often complicated by loosening of pins. It has been reported that coating with hydroxyapatite improves fixation and reduces the rate of pin-track infection. Materials and Methods: We compared 47 hydroxyapatite-coated Schanz screws (HA screws) in 12 monolateral fixators mounted at the University Hospital Hamburg–Eppendorf with 45 standard stainless steel screws in 9 monolateral fixators mounted at the St Josefs-Hospital Wiesbaden by measuring the insertion and extraction torque values. The average implantation period was 7 months for the hydroxyapatite-coated screws and 5.4 months for the uncoated screws. We established the quotient of the maximum extraction torque over insertion torque which shows the change in the fixation strength with respect to time, the fixation index. It eliminates the influence of the varying pin–bone contact. Results: There was no significant difference in the rate of infection. In the Schanz screws without signs of infection the index was 1.92 for the HA screws and 0.76 for the stainless steel screws (= 0.0002) giving evidence of the improvement of the fixation by the coating. Conclusion: HA coating resulted in improved fixation of Schanz screws in bone and may be useful in prolonged external fixation of the lower leg. The fixation index proved to be a simple tool for the evaluation of the fixation strength of Schanz screws.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Similar content being viewed by others

Reference

  1. Augat P, Claes L, Hanselmann KF, Suger G, Fleischmann W (1995) Increase of stability in fracture fixation by hydroxyapatite-coated bone screws. J Appl Biomater 6:99–104

    Article  PubMed  CAS  Google Scholar 

  2. Cordoba F, Dong SS, Robinson M, States BS, Nimni ME (1993) Effects of microcrystalline hydroxyapatite on bone marrow stromal cell osteogenesis. 39th Annual meeting, Orthopaedic Research Society, San Francisco, CA, pp 15–18

  3. Dávid A, Pommer A, Eitenmüller J, Muhr G (1993) Der Einfluß der Hydroxylapatit-Beschichtung von AO/ASIF-Schrauben auf die Haftfestigkeit im Knochen. Unfallchirurg 96:12–17

    PubMed  Google Scholar 

  4. Harada Y, Wang JT, Doppalapudi VA, Willis AA, Jasty M, Harris WH, Goldring SR (1994) Effects of hydroxyapatite/tricalciumphosphate particulates on human macrophage/monocytes in vitro. 40th Annual meeting, Orthopaedic Research Society, New Orleans, LA, pp 21–24

  5. Magyar G, Toksvig-Larsen S, Moroni A (1997) Hydroxyapatite coating of threaded pins enhances fixation. J Bone Joint Surg Br 79-B:487–489 doi: 0301–620X/97/37190

    Google Scholar 

  6. Meiss L (1991) Experimentelle Untersuchungen und klinische Ergebnisse zur Stimulation der Knochenregeneration mit zerkleinerter Kortikalis und porösen Kalziumphosphatkeramiken (Trikalziumphosphat und Hydroxiapatit). Hefte zur Unfallheilkunde, Heft 216, Huggler AH, Kuner EH (Hrsg.), Springer, Berlin Heidelberg New York, pp 85–97

  7. Moroni A, Aspenberg P, Toksvig-Larsen S, Falzarano G, Giannini S (1998) Enhanced fixation with hydroxyapatite coated pins. Clin Orthop Relat Res 346:171–177

    Article  PubMed  Google Scholar 

  8. Moroni A, Toksvig-Larsen S, Maltarello MC, Orienti L, Stea S, Giannini S (1998) A comparison of hydroxyapatite-coated, titanium-coated and uncoated tapered external fixation pins. J Bone Joint Surg Am 80-A:547–554

    Google Scholar 

  9. Moroni A, Faldini C, Marchetti S, Manca M, Consoli V, Giannini S (2001) Improvement of the bone–pin interface strength in osteoporotic bone with use of hydroxyapatite-coated tapered external fixation pins. J Bone Joint Surg Am 83-A 717–721

    PubMed  CAS  Google Scholar 

  10. Moroni A, Heikkila J, Magyar G, Toksvig-Larsen S, Giannini S (2001) Fixation strength and pin tract infection of hydroxyapatite-coated tapered pins. Clin Orthop Relat Res 388:209–217

    Article  PubMed  Google Scholar 

  11. Moroni A, Faldini C, Pegreffi F, Giannini S (2004) HA-coated screws decrease the incidence of fixation failure in osteoporotic trochanteric fractures. Clin Orthop Relat Res 425:87–92

    Article  PubMed  Google Scholar 

  12. Pettine KA, Chao EY, Kelly PJ (1993) Analysis of the external fixator pin–bone interface. Clin Orthop Relat Res 293:18–27

    PubMed  Google Scholar 

  13. Placzek R, Hempfing A, Meiss AL (2001) Evaluation of hydroxyapatite-coated Schanz screws used in the Heidelberg external fixation system (HEFS). Biomed Tech 46:172–175

    CAS  Google Scholar 

  14. Placzek R, Deuretzbacher G, Meiss AL (2002) Bone fixation strength of the hydroxyapatite-coated Schanz-screws of the Heidelberg external fixation system (HEFS)—determination of torque in clinical application and in a cadaver tibia. Biomed Tech 47:323–325

    Article  CAS  Google Scholar 

  15. Pizà G, Caja VL, Gonzàlez-Viejo MA, Navarro A (2004) Hydroxyapatite-coated external-fixation pins; the effect on pin loosening and pin-track infection in leg lengthening for short stature. J Bone Joint Surg Br 86-B:892–897 doi: 10.1302/0301–620X.86B.13875

  16. Pommer A, Muhr G, Dàvid A (2002) Hydroxyapatite-coated Schanz pins in external fixators used for distraction osteogenesis: a randomised, controlled trial. J Bone Joint Surg Am 84:1162–1166

    Article  PubMed  Google Scholar 

  17. Sandén B, Olerud C, Petrén-Mallmin M, Larsson S (2002) Hydroxyapatite coating improves fixation of pedicle screws: a clinical study. J Bone Joint Surg Br 84:387–391 doi: 0301–620X/02/312388

    Google Scholar 

  18. Schmidt HG, Neikes M, Wittek F (1990) Die Klassifikation der Osteomyelitis. Aktuelle Traumatol 20(6):303–309

    PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to R. Placzek.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Placzek, R., Ruffer, M., Deuretzbacher, G. et al. The fixation strength of hydroxyapatite-coated Schanz screws and standard stainless steel Schanz screws in lower extremity lengthening. Arch Orthop Trauma Surg 126, 369–373 (2006). https://doi.org/10.1007/s00402-006-0142-5

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00402-006-0142-5

Keywords

Navigation