Skip to main content
Log in

Successful localization and ablation of a Mahaim potential using a high-resolution mapping catheter after a failed conventional ablation attempt

  • Letter to the Editors
  • Published:
Clinical Research in Cardiology Aims and scope Submit manuscript

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

References

  1. Heald SC, Davies DW, Ward DE et al (1995) Radiofrequency catheter ablation of Mahaim tachycardia by targeting Mahaim potentials at the tricuspid annulus. Br Heart J 73:250–257

    Article  PubMed  PubMed Central  CAS  Google Scholar 

  2. Mounsey JP, Griffith MJ, McComb JM (1994) Radiofrequency ablation of a Mahaim fiber following localization of Mahaim pathway potentials. J Cardiovasc Electrophysiol 5:432–437

    Article  PubMed  CAS  Google Scholar 

  3. Anter E, Tschabrunn CM, Josephson ME (2015) High-resolution mapping of scar-related atrial arrhythmias using smaller electrodes with closer interelectrode spacing. Circ Arrhythm Electrophysiol 8:537–545. https://doi.org/10.1161/CIRCEP.114.002737

    Article  PubMed  Google Scholar 

  4. Haissaguerre M, Warin JF, Le Métayer P et al (1990) Catheter ablation of Mahaim fibers with preservation of atrioventricular nodal conduction. Circulation 82:418–427

    Article  PubMed  CAS  Google Scholar 

  5. Asakai H, Fenwick L, Hamilton RM (2016) Electroanatomical voltage mapping of atrial Mahaim potentials to guide catheter ablation. Heart Rhythm Case Rep 2:499–501. https://doi.org/10.1016/j.hrcr.2016.07.008

    Article  Google Scholar 

  6. Gupta A, Hsia HH, Lo R, Zei PC (2011) Electroanatomic localization of a slowly conducting atrioventricular (Mahaim) accessory pathway. J Interv Card Electrophysiol 31:119–124. https://doi.org/10.1007/s10840-009-9440-5

    Article  PubMed  Google Scholar 

  7. Kosiuk J, Lindemann F, Hindricks G, Bollmann A (2016) Termination of the left atrial tachycardia by the ablation of epicardial critical isthmus visualized with a novel high-resolution mapping system. Clin Res Cardiol 105:1049–1050. https://doi.org/10.1007/s00392-016-1030-9

    Article  PubMed  Google Scholar 

  8. Walsh KA, Galvin J, Keaney J et al (2017) Automated ultra-high-density mapping of peri-sinus node premature atrial contractions. Clin Res Cardiol. https://doi.org/10.1007/s00392-017-1191-1

    Article  PubMed  Google Scholar 

  9. Santoro F, Sohns C, Saguner AM et al (2017) Endocardial voltage mapping of pulmonary veins with an ultra-high-resolution system to evaluate atrial myocardial extensions. Clin Res Cardiol 106:293–299. https://doi.org/10.1007/s00392-016-1053-2

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Eberhard P. Scholz.

Electronic supplementary material

Below is the link to the electronic supplementary material.

Supplementary material 1 (PDF 525 KB)

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Lugenbiel, P., Xynogalos, P., Schweizer, P. et al. Successful localization and ablation of a Mahaim potential using a high-resolution mapping catheter after a failed conventional ablation attempt. Clin Res Cardiol 107, 607–610 (2018). https://doi.org/10.1007/s00392-018-1231-5

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00392-018-1231-5

Navigation