Postoperative Betreuung von Patienten nach alloprothetischem Herzklappenersatz

Neue Methoden zur Risikosenkung sowie Früherkennung von Prothesendysfunktionen

Home monitoring of patients after prosthetic valve replacement—a new method of early detection of valve dysfunction

  • ÜBERSICHT
  • Published:
Zeitschrift für Kardiologie Aims and scope Submit manuscript

Summary.

Despite enormous progress concerning material and design, patients with artificial heart valves still face a considerable risk of serious complications (e. g. hemorrhage, thromboemboli, redos) which sum up to 5–20% within the first 10 postoperative years depending on type and position of the implanted prosthetic valve. Nowadays technical defects of mechanical valves are negligible and relevant complications are most frequently the consequence of inappropriate oral anticoagulation therapy. To avoid these complications a strict control of both the anticoagulation therapy and the functional integrity of the prosthetic valve is mandatory. Therefore with the aim of risk minimization the patient should be enabled to cooperate by means of methods which are easy to handle in his everyday environment. We present a reliable method for early detection of prosthetic valve dysfunction which can be applied daily with minimal effort by the patient himself.

Zusammenfassung.

Patienten mit einem alloprothetischem Herzklappenersatz haben trotz erheblicher Fortschritte hinsichtlich des Materials und des Designs der Prothesen noch immer ein Risiko eine ernste Komplikation (Blutung, Thrombembolie, Re-Operation) zu erleiden, welches sich in den ersten 10 postoperativen Jahren je nach Klappentyp und Klappenposition auf 5–20% summiert. Dabei sind technische Defekte an mechanischen Herzklappen heute zu vernachlässigen. Vielmehr sind relevante Komplikationen im Langzeitverlauf häufig mit der korrekten Antikoagulation verbunden. Um diese zu vermeiden, erachten wir eine möglichst engmaschige Kontrolle sowohl des Gerinnungsstatus als auch der funktionellen Integrität der Herzklappenprothese als unabdingbar. Dabei kommt es wesentlich darauf an, den Patienten selbst in die Lage zu versetzen, mittels einfacher und beliebig oft in seiner alltäglichen Umwelt durchzuführender Methoden an der Risikominimierung mitzuwirken. Wir stellen eine zuverlässige Methode vor, mit der vom Patienten ohne größeren Aufwand beliebig häufig die funktionelle Integrität seiner Kunstklappe überprüft werden kann.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Takkenberg JJM, Puvimanasinghe JPA, van Herweden LA, Steyerberg EW, Eijkemans MJC, Habbema JDF, Bogers AJJC (2001) Prognosis after aortic valve replacement with St. Jude Medical bileaflet prostheses: impact of the GELIA Database (GELIA 4), Vol 3. Europ Heart J, Suppl Q27–32

    Google Scholar 

  2. Huth C, Rost F (2001) Intensity of oral anticoagulation after implantation of St. Jude Medical aortic prosthesis: analysis of the GELIA Database (GELIA 4), Vol 3. Europ Heart J, Suppl Q33–38

    Google Scholar 

  3. Pruefer D, Dahm M, Dohmen G, Horstkotte D, Bergemann R, Oelert H (2001) Intensity of oral anticoagulation after implantation of St. Jude Medical mitral or multiple valve replacement: lessons learned from GELIA (GELIA5). Europ Heart J, Suppl 3:Q39–43

    Google Scholar 

  4. Horstkotte D, Burkhardt D (1995) Prosthetic valve thrombosis. J Heart Valve Dis 4:141–153

    CAS  PubMed  Google Scholar 

  5. Piper C, Hering D, Horstkotte D (2001) Prosthetic valve thrombosis predisposition and diagnosis. Europ Heart J, Suppl 3:Q16–21

    Google Scholar 

  6. Piper C, Horstkotte D (2004) State of the art anticoagulation management. J Heart Valve Dis 13 (in press)

  7. Salem DN, Stein PD, Al-Ahmad A, Bussey HI, Horstkotte D, Miller N, Pauker S (2004) Antithrombotic Therapy in Valvular Heart Disease: Native and Prosthetic. 7th ACCP Consensus Conference on Antithrombotic Therapy. Chest (in press)

  8. Marek G, Niehus R, Schunicht R, Klein RM, Esser G, Horstkotte D (1992) Schallspektrographische Untersuchungen an St. Jude Medical (SJM) und Björk-Shiley Monostrut (BSM) Aortenklappenprothesen. Z Kardiol (Suppl 3):52

  9. Niehus R, Bagner J, Klein RM, Schunicht R, Horstkotte D (1994) Vorhersagbarkeit von Bügelbrüchen konvexkonkaver Björk-Shiley Mitralklappenprothesen (BScc) durch schallspektroskopische Untersuchungen. Z Kardiol 83 (Suppl 1):165

    PubMed  Google Scholar 

  10. Eitz T, Fritzsche D, Grimmig O, Frerichs I, Frerichs A, Hellige G, Minami K, Körfer R (2003) Acoustic Phenomena and Valve Dysfunction in Cardiac Prostheses: Data Acquisition and Collection via the Internet. J Heart Valve Disease 12:414–419

    Google Scholar 

  11. Koertke H, Minami K, Boethig D, Breymann T, Seifert D, Wagner O et al (2003) INR Self-Management Permits Lower Anticoagulation Levels after Mechanical Heart Valve Replacement. Circulation 108(Suppl II):II75–78

    Article  CAS  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to D. Fritzsche.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Fritzsche, D., Eitz, T., Grimmig, O. et al. Postoperative Betreuung von Patienten nach alloprothetischem Herzklappenersatz. Z Kardiol 93, 664–670 (2004). https://doi.org/10.1007/s00392-004-0114-0

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00392-004-0114-0

Key words

Schlüsselwörter

Navigation