Skip to main content
Log in

Measurement of flow structures and heat transfer behind a wall-proximity square rib using TSP, PIV and split-fiber film

  • Research Article
  • Published:
Experiments in Fluids Aims and scope Submit manuscript

Abstract

In the present study, complementary measurement techniques—temperature sensitive paint (TSP), planar particle image velocimetry (planar PIV) and a split-fiber film probe—were used to investigate the effects of a “wall-proximity square rib” on flow structure and surface heat transfer augmentation. TSP was used to measure the time-averaged wall temperature field at three different Reynolds numbers (\( Re_{d} \) = 3800, 7600 and 11,400) based on the rib height d and the mainstream velocity \( U_{o} \), and wall-proximity configurations with four different gap ratios (gap size \( G \) over rib height d), G/d = 0, 0.25, 0.50 and 0.75. The two-dimensional distribution of the normalized Nusselt number convincingly demonstrated the existence of a hot spot immediately behind the rib in the attached rib configuration (G/d = 0) and surface heat transfer augmentation in the reattachment zone. Among the three wall-proximity configurations, G/d = 0.25 resulted in maximum heat transfer augmentation immediately behind the rib and overall improvement in surface heat removal. However, no distinctly different spatial patterns of the normalized Nusselt number distribution were found at the three different Reynolds numbers. A subsequent experiment examined the flow pattern and flow structures at \( Re_{d} \) = 7600 and three wall-proximity configurations (G/d = 0, 0.25 and 0.50). Velocity field measurements using PIV, along with complementary measurements using split-fiber film, gave a clear view of the flow pattern behind the rib; a very slender separation bubble with highly unsteady flow reversal was found close to the surface when G/d = 0.25. For configurations with G/d = 0.25 and 0.50, the high-speed jet issuing from the gap had a complicated influence on the interaction between the upper free shear layer and lower strong shear layer, resulting in slanted movement of the coupled wake flow. Proper orthogonal decomposition was used to identify the spatial characteristics of the superimposed flow structures. In the configuration G/d = 0.25, coherent structures were found throughout most of the wake region, beginning roughly 1.2d behind the rib. Fluid flow in the region near the wall was strongly influenced by the dominant coherent structures, which were evidently the main mechanism for surface heat removal. In the configuration with G/d = 0.50, the area with large velocity fluctuation intensity shifted away from the wall toward the mainstream due to rapid expansion of the wall jet. This, in combination with large-scale coherent structures from the surface, meant a much reduced influence on the fluid near the wall and a corresponding deterioration of surface heat transfer beyond the station x/d = 4 (x being the downstream distance from the rib’s trailing edge).

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12
Fig. 13
Fig. 14

Similar content being viewed by others

Abbreviations

A :

Area of the heating foil

d :

Rib size

f T :

TSP calibration function

G :

Gap size

I :

Emission intensity

I R :

Emission intensity ratio

P :

Power of the heating foil

T :

Temperature

T R :

Reference temperature

U :

Time-averaged streamwise velocity

U 0 :

Mainstream velocity

u :

Streamwise fluctuation velocity

v :

Wall-normal fluctuation velocity

\( \widehat{v} \) :

Wall-normal component of the normalized POD mode

x :

x coordinate

y :

y coordinate

z :

z coordinate

Re d :

Reynolds number based on rib size

St :

Strouhal number

δ :

Boundary layer thickness

λ :

Thermal conductivity of the inflowing air

γ t :

Reverse-flow intermittency

Ω :

Spanwise vorticity

LDV:

Laser Doppler velocimetry

PIV:

Particle image velocimetry

POD:

Proper orthogonal decomposition

TLC:

Thermochromic liquid crystal

TSP:

Temperature sensitive paint

References

  • Ahn J, Lee JS (2010) Large eddy simulation of flow and heat transfer in a channel with a detached rib array. Int J Heat Mass Transf 53:445–452

    Article  MATH  Google Scholar 

  • Bailey S, Kopp G, Martinuzzi R (2002) Vortex shedding from a square cylinder near a wall. J Turbul 3:1–18

    Article  MATH  Google Scholar 

  • Bearman P, Zdravkovich M (1978) Flow around a circular cylinder near a plane boundary. J Fluid Mech 89:33–47

    Article  Google Scholar 

  • Bosch G, Kappler M, Rodi W (1996) Experiments on the flow past a square cylinder placed near a wall. Exp Therm Fluid Sci 13:292–305

    Article  Google Scholar 

  • Cho H-H, Kim Y, Rhee D-H, Lee S, Wu S, Choi C (2003) The effects of gap position in discrete ribs on local heat/mass transfer in a square duct. J Enhanc Heat Transf 10

  • Cukurel B, Selcan C, Stratmann M (2015) Convective heat transfer investigation of acoustically excited flow over an isolated rib obstacle. Int J Heat Mass Transf 91:848–860

    Article  Google Scholar 

  • Durao D, Gouveia P, Pereira J (1991) Velocity characteristics of the flow around a square cross section cylinder placed near a channel wall. Exp Fluids 11:341–350

    Article  Google Scholar 

  • Griffith TS, Al-Hadhrami L, Han J-C (2002) Heat transfer in rotating rectangular cooling channels (AR = 4) with angled ribs. J Heat Transf 124:617–625

    Article  Google Scholar 

  • Han J-C, Dutta S, Ekkad S (2012) Gas turbine heat transfer and cooling technology. CRC Press, Boca Raton

    Google Scholar 

  • Kiya M, Sasaki K (1983) Structure of a turbulent separation bubble. J Fluid Mech 137:83–113

    Article  Google Scholar 

  • Lim JS (1990) Two-dimensional signal and image processing. Englewood Cliffs, Prentice Hall 34:6–8

    Google Scholar 

  • Liou T-M, Wang W-B (1995) Laser holographic interferometry study of developing heat transfer in a duct with a detached rib array. Int J Heat Mass Transf 38:91–100

    Article  Google Scholar 

  • Liou T-M, Wang W-B, Chang Y-J (1995) Holographic interferometry study of spatially periodic heat transfer in a channel with ribs detached from one wall. J Heat Transf 117:32–39

    Article  Google Scholar 

  • Liou T-M, Yang C-P, Lee H-L (1997) LDV measurements of spatially periodic flows over a detached solid-rib array. J Fluids Eng 119:383–389

    Article  Google Scholar 

  • Liu Y, Ke F, Sung H (2008) Unsteady separated and reattaching turbulent flow over a two-dimensional square rib. J Fluids Struct 24:366–381

    Article  Google Scholar 

  • Martinuzzi R, Bailey S, Kopp G (2003) Influence of wall proximity on vortex shedding from a square cylinder. Exp Fluids 34:585–596

    Article  MATH  Google Scholar 

  • Marumo E, Suzuki K, Sato T (1985) Turbulent heat transfer in a flat plate boundary layer disturbed by a cylinder. Int J Heat Fluid Flow 6:241–248

    Article  Google Scholar 

  • Paul S, Tachie M, Katopodis C (2009) Influence of the leading edge geometry on the near-wake of rectangular cylinders 39th AIAA fluid dynamics conference, pp 3699

  • Price S, Sumner D, Smith J, Leong K, Paidoussis M (2002) Flow visualization around a circular cylinder near to a plane wall. J Fluids Struct 16:175–191

    Article  Google Scholar 

  • Rempfer D, Fasel HF (1994) Evolution of three-dimensional coherent structures in a flat-plate boundary layer. J Fluid Mech 260:351–375

    Article  Google Scholar 

  • Shi LL, Liu YZ, Sung HJ (2010a) On the wake with and without vortex shedding suppression behind a two-dimensional square cylinder in proximity to a plane wall. J Wind Eng Ind Aerodyn 98:492–503

    Article  Google Scholar 

  • Shi LL, Liu YZ, Wan JJ (2010b) Influence of wall proximity on characteristics of wake behind a square cylinder: PIV measurements and POD analysis. Exp Therm Fluid Sci 34:28–36

    Article  Google Scholar 

  • Sirovich L (1987) Turbulence and the dynamics of coherent structures. Part I: coherent structures. Q Appl Math 45:561–571

    MathSciNet  MATH  Google Scholar 

  • Taneda S (1965) Experimental investigation of vortex streets. J Phys Soc Jpn 20:1714–1721

    Article  Google Scholar 

  • Wilson BM, Smith BL (2013) Uncertainty on PIV mean and fluctuating velocity due to bias and random errors. Meas Sci Technol 24:390–392

    Google Scholar 

  • Zhang Q, Liu Y (2015) Influence of incident vortex street on separated flow around a finite blunt plate: PIV measurement and POD analysis. J Fluids Struct 55:463–483

    Article  Google Scholar 

Download references

Acknowledgements

The authors gratefully acknowledge financial support from the National Natural Science Foundation of China (No. 11372189), “Shuguang Program” by Shanghai Education Development Foundation and Shanghai Municipal Education Commission, and the Chinese “111” Program of Introducing Talents of Discipline to Universities.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Yingzheng Liu.

Ethics declarations

Conflict of interest

The authors declare that they have no conflict of interest.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

He, C., Liu, Y., Peng, D. et al. Measurement of flow structures and heat transfer behind a wall-proximity square rib using TSP, PIV and split-fiber film. Exp Fluids 57, 165 (2016). https://doi.org/10.1007/s00348-016-2262-1

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1007/s00348-016-2262-1

Keywords

Navigation