Abstract
A stereomicroscopic particle image velocimetry (SμPIV) system has been developed for millimeter scale flows. The SμPIV system is based on an off-the-shelf stereomicroscope, with magnification between 0.69× and 30×, and a field of view between 7.5 × 6 mm and 250 × 200 μm. Custom calibration targets were devised using printed circuit board technology, and applied at a magnification factor of 1.74, with a field of view of 4.75 × 3.8 mm. Measurement errors were assessed by moving a test block with fixed particles. Total system uncertainty in test block displacement transverse to the optical axis was 0.5% of the field of view, and 3% of the depth of field for motion along the optical axis. Approximately 20% of this uncertainty was due to the calibration target quality and test block procedures.
Similar content being viewed by others
References
Bown MR, MacInnes JM, Allen RWK, Zimmermann WBJ (2005) Three-component micron resolution velocity measurements using sterescopic Micro-PIV. In: Proceedings of the 6th international symposium on particle image velocimentry, paper S06–S06
Bown MR, MacInnes JM, Allen RWK, Zimmerman WBJ (2006) Three-dimensional, three-component measurements using stereoscopic micro-PIV and PTV. Meas Sci Technol 17:2175–2185. doi:10.1088/0957-0233/17/8/017
Giardino J (2004) Stereomicroscopic particle image velocimetry. MS thesis, University of Colorado, Boulder
Giardino JP, Hertzberg JR, Bradley E (2004) Stereomicroscopic particle image velocimetry. In: Proceedings of the11th international symposium on flow visualization. University of Notre Dame, Notre Dame, CD ROM, paper 247
Hertzberg J, Giardino J, Bradley E (2004) A stereo-microscopic particle image velocimetry system, Paper NC-001. American Physical Society 57th Annual Meeting of the Division of Fluid Dynamics, Seattle. Abstract published in Bull APS 49(9):214
Inoue S, Spring K (1997) Video microscopy, 2nd edn. Plenum Press, New York
Klank H, Goranovi G, Kutter JP, Gjelstrup H, Michelsen J, Westergaard CH (2002) PIV measurements in a microfluidic 3D-sheathing structure with three-dimensional flow behaviour. J Micromech Microeng 12:862–869.http://stacks.iop.org/JMM/12/862
Lawson NJ, Wu J (1997) Three-dimensional particle image velocimetry: experimental error analysis of a digital angular stereoscopic system. Meas Sci Technol 8:1455–1464
Lindken R, Westerweel J, Wieneke B (2005a) Stereoscopic micro PIV applied to the three-dimensional flow in a T-mixer. In: Proceedings of the PIVNET2 international workshop on lPIV and applications in microsystems, Delft
Lindken R, Westerweel J, Wieneke B (2005b) Development of a stereoscopic micro particle image velocimetry system (stereoμPIV) and first measurements of the three-dimensional flow structure in a T-micromixer. In: Proceedings of the Euromech colloquium 472 on microfluidics and transfer, Grenoble
Lindken R, Westerweel J, Wienke B (2006) Stereoscopic micro particle image velocimetry. Exp Fluids 41:161–171. doi:10.1007/s00348-006-0154-5
Maas HG (1996) Contributions of digital photogrammetry to 3-D PTV. In: Dracos T (ed) Three-dimensional velocity and vorticity measuring and image analysis techniques. Kluwer, Dordrecht, pp 191–208
Meinhart CD, Wereley ST (2003) The theory of diffraction-limited resolution in microparticle image velocimetry. Meas Sci Technol 14:1047–1053 http://stacks.iop.org/MST/14/1047
Meinhart CD, Wereley ST, Santiago JG (2000) A PIV algorithm for estimating time-averaged velocity fields. J Fluids Eng 22:285–289
Olsen MG, Adrian RJ (2000) Out-of-focus effects on particle image visibility and correlation in microscopic particle image velocimetry. Exp Fluids 29:166–174
Raffel M, Willert C, Kompenhans J (1998) Particle image velocimetry: a practical guide. Springer, Heidelberg
Wieneke B (2005) Stereo-PIV using self-calibration on particle images. Exp Fluids 39:267–280
Acknowledgments
This material is based upon work supported by the National Science Foundation under Awards No. 0114109 and 0083004. Any opinions, findings, and conclusions or recommendations expressed in this material are those of the author and do not necessarily reflect the views of the National Science Foundation (NSF). This work complies with the current laws of the United States of America.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Giardino, J., Hertzberg, J. & Bradley, E. A calibration procedure for millimeter-scale stereomicroscopic particle image velocimetry. Exp Fluids 45, 1037–1045 (2008). https://doi.org/10.1007/s00348-008-0525-1
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00348-008-0525-1