Skip to main content
Log in

True targeting-derived prostate biopsy: HistoScanning™ remained inadequate despite advanced technical efforts

  • Original Article
  • Published:
World Journal of Urology Aims and scope Submit manuscript

Abstract

Purpose

To verify the reliability of HistoScanning™-based, true targeting (TT)-derived prostate biopsy.

Methods

We relied on 40 patients suspicious for prostate cancer who underwent standard and TT-derived prostate biopsy. Sensitivity, specificity, positive predictive value, negative predictive value and the area under the curve (AUC) were assessed for the prediction of biopsy results per octant by HistoScanning™, using different HistoScanning™ signal volume cutoffs (>0, >0.2 and >0.5 ml).

Results

Overall, 319 octants were analyzed. Of those, 64 (20.1 %) harbored prostate cancer. According to different HistoScanning™ signal volume cutoffs (>0, >0.2 and >0.5 ml), the AUCs for predicting biopsy results were: 0.51, 0.51 and 0.53, respectively. Similarly, the sensitivity, specificity, positive predictive and negative predictive values were: 20.7, 78.2, 17.4 and 81.6 %; 20.7, 82.0, 20.3 and 82.3 %; and 12.1, 94.6, 33.3 and 82.9 %, respectively.

Conclusions

Prediction of biopsy results based on HistoScanning™ signals and TT-derived biopsies was unreliable. Moreover, the AUC of TT-derived biopsies was low and did not improve when additional signal volume cutoffs were applied (>0.2 and >0.5 ml). We cannot recommend a variation of well-established biopsy standards or reduction in biopsy cores based on HistoScanning™ signals.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1

Similar content being viewed by others

References

  1. Schiffmann J, Manka L, Boehm K, Leyh-Bannurah SR, Karakiewicz PI, Graefen M, Hammerer P, Salomon G (2015) Controversial evidence for the use of HistoScanning in the detection of prostate cancer. World J Urol. doi:10.1007/s00345-015-1555-y

    Google Scholar 

  2. Nunez-Mora C, Garcia-Mediero JM, Patino P, Orellana C, Garrido A, Rojo A, Rendon D (2013) Utility of Histoscanning prior to prostate biopsy for the diagnosis of prostate adenocarcinoma. Actas Urol Esp. doi:10.1016/j.acuro.2013.01.003

    PubMed  Google Scholar 

  3. Schiffmann J, Tennstedt P, Fischer J, Tian Z, Beyer B, Boehm K, Sun M, Gandaglia G, Michl U, Graefen M, Salomon G (2014) Does HistoScanning predict positive results in prostate biopsy? A retrospective analysis of 1,188 sextants of the prostate. World J Urol 32(4):925–930. doi:10.1007/s00345-014-1330-5

    Article  CAS  PubMed  Google Scholar 

  4. Javed S, Chadwick E, Edwards AA, Beveridge S, Laing R, Bott S, Eden C, Langley S (2013) Does HistoScanning play a role in detecting prostate cancer in routine clinical practice? Results from three independent studies. BJU Int. doi:10.1111/bju.12568

    PubMed  Google Scholar 

  5. Sivaraman A, Sanchez-Salas R, Barret E, Macek P, Validire P, Galiano M, Rozet F, Cathelineau X (2014) Prostate histoscanning true targeting guided prostate biopsy: initial clinical experience. World J Urol. doi:10.1007/s00345-014-1434-y

    PubMed  Google Scholar 

  6. Schiffmann J, Connan J, Salomon G, Boehm K, Beyer B, Schlomm T, Tennstedt P, Sauter G, Karakiewicz PI, Graefen M, Huland H (2015) Tumor volume in insignificant prostate cancer: increasing threshold gains increasing risk. Prostate 75(1):45–49. doi:10.1002/pros.22889

    Article  CAS  PubMed  Google Scholar 

  7. Braeckman J, Autier P, Garbar C, Marichal MP, Soviany C, Nir R, Nir D, Michielsen D, Bleiberg H, Egevad L, Emberton M (2008) Computer-aided ultrasonography (HistoScanning): a novel technology for locating and characterizing prostate cancer. BJU Int 101(3):293–298. doi:10.1111/j.1464-410X.2007.07232.x

    Article  PubMed  Google Scholar 

  8. Braeckman J, Autier P, Soviany C, Nir R, Nir D, Michielsen D, Treurnicht K, Jarmulowicz M, Bleiberg H, Govindaraju S, Emberton M (2008) The accuracy of transrectal ultrasonography supplemented with computer-aided ultrasonography for detecting small prostate cancers. BJU Int 102(11):1560–1565. doi:10.1111/j.1464-410X.2008.07878.x

    Article  PubMed  Google Scholar 

  9. Javed S, Chadwick E, Beveridge S, Bott S, Eden C, Langley S (2013) Does prostate Histoscanning™ accurately identify prostate cancer, measure tumour volume and assess pathological stage prior to radical prostatectomy? J Clin Urol. doi:10.1177/2051415813489682

    Google Scholar 

  10. Macek P, Barret E, Sanchez-Salas R, Galiano M, Rozet F, Ahallal Y, Gaya JM, Durant M, Mascle L, Giedelman C, Lunelli L, Validire P, Nesvadba M, Cathelineau X (2013) Prostate Histoscanning in clinically localized biopsy proven prostate cancer: an accuracy study. J Endourol. doi:10.1089/end.2013.0419

    PubMed  Google Scholar 

  11. Schiffmann J, Fischer J, Tennstedt P, Beyer B, Bohm K, Michl U, Graefen M, Salomon G (2013) Comparison of prostate cancer volume measured by HistoScanning and final histopathological results. World J Urol. doi:10.1007/s00345-013-1211-3

    PubMed  Google Scholar 

  12. Schiffmann J, Beyer B, Fischer J, Tennstedt P, Boehm K, Michl U, Graefen M, Salomon G (2014) Histoscanning has low sensitivity and specificity for seminal vesicle invasion. Urology 84(5):1168–1171. doi:10.1016/j.urology.2014.06.050

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Jonas Schiffmann.

Ethics declarations

Conflict of interest

The authors declare that they have no conflict of interest according to the current manuscript.

Ethical standard

The current manuscript has no conflict with ethical standards set by the Declaration of Helsinki.

Additional information

Jonas Schiffmann and Gisa Mehring have contributed equally to this work.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Schiffmann, J., Mehring, G., Tennstedt, P. et al. True targeting-derived prostate biopsy: HistoScanning™ remained inadequate despite advanced technical efforts. World J Urol 34, 495–500 (2016). https://doi.org/10.1007/s00345-015-1637-x

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00345-015-1637-x

Keywords

Navigation