Skip to main content
Log in

Off-site evaluation of liver lesion detection by Gd-BOPTA-enhanced MR imaging

  • ABDOMINAL
  • Published:
European Radiology Aims and scope Submit manuscript

Abstract

The aim of this study was to determine the efficacy of Gd-BOPTA-enhanced MRI in liver lesion detection in comparison with unenhanced MRI and dynamic CT. The image sets of 148 of 151 patients enrolled in a multicenter German phase-III trial were evaluated by two independent radiologists unaffiliated with the investigating centers. Patients underwent a routine MRI protocol comprising T2- and T1-weighted spin-echo and T1-weighted gradient-echo (GE) sequences pre and 1 h post 0.1 mmol/kg Gd-BOPTA (Bracco-Byk Gulden, Konstanz, Germany). Additionally, a serial T1-weighted GE scan was performed after administration of the first half of the dose. All patients underwent dynamic contrast-enhanced CT. The evaluation was performed with regard to the number and size of lesions detected per patient by each modality or sequence. Furthermore, all pre CM and pre + post CM image sets were analyzed for number of lesions per patient. Both readers detected significantly more lesions in the contrast-enhanced image set compared with the unenhanced image set (32 and 39 %, respectively; p < 0.0001). While contrast-enhanced CT detected a similar number of lesions to unenhanced MRI, it was clearly inferior to contrast-enhanced MRI (reader 1: p = 0.0117; reader 2: p = 0.0225). Of the T1-weighted scans performed, the dynamic and late T1-weighted GE exams contributed most to the increased lesion detection rate (reader 1: p = 0.0007; reader 2: p = 0.0037). The size of the smallest lesion detected by means of MRI was significantly larger in the pre-CM image sets than in the pre + post CM image sets (reader 1: p = 0.001; reader 2: p < 0.0001). Gd-BOPTA-enhanced MRI detected significantly smaller lesions than contrast-enhanced CT (reader 1: p = 0.0117; reader 2: p = 0.0925). Gd-BOPTA-enhanced MR imaging improves liver lesion detection significantly over unenhanced MRI and dynamic CT.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received: 18 October 1999/Revised: 19 June 2000/Accepted: 21 June 2000

Rights and permissions

Reprints and permissions

About this article

Cite this article

Gehl, HB., Bourne, M., Grazioli, L. et al. Off-site evaluation of liver lesion detection by Gd-BOPTA-enhanced MR imaging. Eur Radiol 11, 187–192 (2001). https://doi.org/10.1007/s003300000593

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s003300000593

Navigation