Abstract

Objectives

To evaluate the safety and technical efficacy of a customized blunt-tip microwave ablation (MWA) electrode for CT-guided ablation of pulmonary ground-glass opacity nodules (GGOs).

Materials and methods

This was a retrospective before-after study. All consented patients with GGOs who underwent MWA treatment using conventional sharp-tip electrodes (group A) between January 2018 and December 2018 or new blunt-tip electrodes (group B) between January 2019 and December 2019 in our institution were included. The individual features of each patient and lesion, as well as technical and clinical information, were collected and analyzed.

Results

Sixteen (7 males, 9 females; mean age, 64.9 ± 12.3 years) and twenty-six (11 males, 15 females; mean age, 66.5 ± 10.7 years) patients were enrolled in groups A and B, respectively. The technique was successfully performed in all patients and a follow-up CT scan at 24 h after MWA showed that the technical efficacy rate was 100% in both groups. Twelve (75.0%) grade I complications were noted in group A, whereas 11 (42.3%) were noted in group B (p = 0.039, chi-square test). No bleeding occurred within the lesions in group B.

Conclusions

The blunt-tip MWA electrode is a safe and technically effective tool for ablating GGO lesions.

Key Points

A new blunt-tip MWA electrode was used for CT-guided ablation of GGO lesions.

The blunt-tip MWA electrode could improve the safety of GGO ablation.

The technical efficacy of ablation was maintained by using the blunt-tip MWA electrode.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

Similar content being viewed by others

Abbreviations

AAH:

Atypical adenomatous hyperplasia

AIS:

Adenocarcinoma in situ

GGO:

Ground-glass opacity

IA:

Invasive adenocarcinomas

MIA:

Minimally invasive adenocarcinomas

MWA:

Microwave ablation

RFA:

Radiofrequency ablation

SD:

Standard deviation

SIR:

Society of Interventional Radiology

References

  1. Wood DE, Kazerooni EA, Baum SL et al (2018) Lung Cancer Screening, Version 3.2018, NCCN Clinical Practice Guidelines in Oncology. J Natl Compr Canc Netw 16(4):412–441. https://doi.org/10.6004/jnccn.2018.0020

    Article  PubMed  Google Scholar 

  2. MacMahon H, Naidich DP, Goo JM et al (2017) Guidelines for management of incidental pulmonary nodules detected on CT images: from the Fleischner Society 2017. Radiology 284(1):228–243. https://doi.org/10.1148/radiol.2017161659

    Article  PubMed  Google Scholar 

  3. Yang X, Ye X, Lin Z et al (2018) Computed tomography-guided percutaneous microwave ablation for treatment of peripheral ground-glass opacity-Lung adenocarcinoma: A pilot study. J Cancer Res Ther 14(4):764–771. https://doi.org/10.4103/jcrt.JCRT_269_18

    Article  PubMed  Google Scholar 

  4. Kodama H, Yamakado K, Hasegawa T et al (2014) Radiofrequency ablation for ground-glass opacity-dominant lung adenocarcinoma. J Vasc Interv Radiol 25(3):333–339. https://doi.org/10.1016/j.jvir.2013.11.035

    Article  PubMed  Google Scholar 

  5. Huang G, Yang X, Li W et al (2020) A feasibility and safety study of computed tomography-guided percutaneous microwave ablation: a novel therapy for multiple synchronous ground-glass opacities of the lung. Int J Hyperthermia 37(1):414–422. https://doi.org/10.1080/02656736.2020.1756467

    Article  PubMed  Google Scholar 

  6. Cazzato RL, Garnon J, Shaygi B et al (2017) Performance of a new blunt-tip coaxial needle for percutaneous biopsy and drainage of “hard-to-reach” targets. Cardiovasc Intervent Radiol 40(9):1431–1439. https://doi.org/10.1007/s00270-017-1663-8

    Article  PubMed  Google Scholar 

  7. Akins EW, Hawkins IF Jr, Mladinich C et al (1989) The blunt needle: a new percutaneous access device. AJR Am J Roentgenol 152(1):181–182. https://doi.org/10.2214/ajr.152.1.181

    Article  CAS  PubMed  Google Scholar 

  8. Moller A, Afshari A, Bjerrum OW (2013) Diagnostic and therapeutic lumbar puncture performed safely and efficiently with a thin blunt needle. Dan Med J 60(9):A4684

    PubMed  Google Scholar 

  9. Sofocleous CT, Bahramipour P, Mele C et al (2002) Transvenous transjugular renal core biopsy with a redesigned biopsy set including a blunt-tipped needle. Cardiovasc Intervent Radiol 25(2):155–157. https://doi.org/10.1007/s00270-001-0093-8

    Article  PubMed  Google Scholar 

  10. Sacks D, McClenny TE, Cardella JF, Lewis CA (2003) Society of Interventional Radiology clinical practice guidelines. J Vasc Interv Radiol 14(9 Pt 2):S199–S202. https://doi.org/10.1097/01.rvi.0000094584.83406.3e

    Article  PubMed  Google Scholar 

  11. Childs JD, Piva SR, Fritz JM (2005) Responsiveness of the numeric pain rating scale in patients with low back pain. Spine (Phila Pa 1976) 30(11):1331–1334. https://doi.org/10.1097/01.brs.0000164099.92112.29

    Article  Google Scholar 

  12. Rodriguez CS (2001) Pain measurement in the elderly: a review. Pain Manag Nurs 2(2):38–46. https://doi.org/10.1053/jpmn.2001.23746

    Article  CAS  PubMed  Google Scholar 

  13. Farrar JT, Young JP Jr, LaMoreaux L, Werth JL, Poole RM (2001) Clinical importance of changes in chronic pain intensity measured on an 11-point numerical pain rating scale. Pain 94(2):149–158. https://doi.org/10.1016/s0304-3959(01)00349-9

    Article  PubMed  Google Scholar 

  14. Goldberg SN, Grassi CJ, Cardella JF et al (2005) Image-guided tumor ablation: standardization of terminology and reporting criteria. Radiology 235(3):728–739. https://doi.org/10.1148/radiol.2353042205

    Article  PubMed  Google Scholar 

  15. Iguchi T, Hiraki T, Gobara H et al (2015) Percutaneous radiofrequency ablation of lung cancer presenting as ground-glass opacity. Cardiovasc Intervent Radiol 38(2):409–415. https://doi.org/10.1007/s00270-014-0926-x

    Article  PubMed  Google Scholar 

  16. Lu CH, Hsiao CH, Chang YC et al (2012) Percutaneous computed tomography-guided coaxial core biopsy for small pulmonary lesions with ground-glass attenuation. J Thorac Oncol 7(1):143–150. https://doi.org/10.1097/JTO.0b013e318233d7dd

    Article  PubMed  Google Scholar 

  17. Inoue D, Gobara H, Hiraki T et al (2012) CT fluoroscopy-guided cutting needle biopsy of focal pure ground-glass opacity lung lesions: diagnostic yield in 83 lesions. Eur J Radiol 81(2):354–359. https://doi.org/10.1016/j.ejrad.2010.11.025

    Article  PubMed  Google Scholar 

  18. de Bazelaire C, Farges C, Mathieu O et al (2009) Blunt-tip coaxial introducer: a revisited tool for difficult CT-guided biopsy in the chest and abdomen. AJR Am J Roentgenol 193(2):W144–W148. https://doi.org/10.2214/AJR.08.2125

    Article  PubMed  Google Scholar 

  19. Lakin PC, Pavcnik D, Bloch RD et al (1999) Percutaneous transjugular kidney biopsy in swine with use of a side-cutting needle with a blunt-tipped stylet. J Vasc Interv Radiol 10(9):1229–1232. https://doi.org/10.1016/s1051-0443(99)70223-x

    Article  CAS  PubMed  Google Scholar 

  20. Klose KC (1992) Modified Tru-Cut needle with exchangeable blunt stylet for safe puncture: technical note. Cardiovasc Intervent Radiol 15(4):251–253. https://doi.org/10.1007/BF02733933

    Article  CAS  PubMed  Google Scholar 

  21. Austin JH, Muller NL, Friedman PJ et al (1996) Glossary of terms for CT of the lungs: recommendations of the Nomenclature Committee of the Fleischner Society. Radiology 200(2):327–331. https://doi.org/10.1148/radiology.200.2.8685321

    Article  CAS  PubMed  Google Scholar 

  22. Scherle-Matamoros CE, Perez-Nellar J, Fernandez-Cue L (2011) Symptomatic vasospasm. Clinical manifestations. Neurocirugia (Astur) 22(2):116–122

    Article  CAS  Google Scholar 

Download references

Acknowledgements

Jiachang Chi and Zhi Wang collected the data of the patients, designed the pipeline of the analysis, and drafted the manuscript. Bo Zhai conceived and coordinated the overall study and revised the manuscript. All authors read and approved the final manuscript.

Funding

This study was supported by the Innovation Funding of Renji Hospital (No. PY2018-III-11).

Author information

Authors and Affiliations

Authors

Corresponding authors

Correspondence to Jiachang Chi or Bo Zhai.

Ethics declarations

Guarantor

The scientific guarantor of this publication is Bo Zhai.

Conflict of interest

The authors of this manuscript declare no relationships with any companies whose products or services may be related to the subject matter of the article.

Statistics and biometry

One of the authors, Min Ding, has significant statistical expertise.

Informed consent

Written informed consent was obtained from all subjects (patients) in this study.

Ethical approval

Institutional Review Board approval was obtained.

Methodology

• Retrospective

• Case-control study

• Performed at one institution

Additional information

Publisher’s note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Chi, J., Wang, Z., Ding, M. et al. Technical safety and efficacy of a blunt-tip microwave ablation electrode for CT-guided ablation of pulmonary ground-glass opacity nodules. Eur Radiol 31, 7484–7490 (2021). https://doi.org/10.1007/s00330-021-07774-4

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00330-021-07774-4

Keywords

Navigation