Abstract
Objectives
To evaluate the potential value of advanced monoenergetic images (AMEIs) on early gastric cancer (EGC) using dual-energy CT (DECT).
Methods
31 EGC patients (19 men, 12 women; age range, 38–81 years; mean age, 57.19 years) were retrospectively enrolled in this study. Conventionally reconstructed polyenergetic images (PEIs) at 120 kV and virtual monoenergetic images (MEIs) and AMEIs at six different kiloelectron volt (keV) levels (from 40 to 90 keV) were evaluated from the 100 and Sn 140 kV dual energy image data, respectively. The visibility and stage migration of EGC for all three image data sets were evaluated and statistically analyzed. The objective and subjective image qualities were also evaluated.
Results
AMEIs at 40 keV showed the best visibility (80.7 %) and the lowest stage migration (35.5 %) for EGC. The stage migration for AMEIs at 40 keV was significantly lower than that for PEIs (p = 0.026). AMEIs at 40 keV had statistically higher CNR in the arterial and portal phases, gastric-specific diagnostic performance and visual sharpness compared with other AMEIs, MEIs and PEIs (all p < 0.05).
Conclusions
AMEIs at 40 keV with MPR increase the CNR of EGC and thus potentially lower the stage migration of EGC.
Key Points
• AMEIs benefits from the recombination of low-keV images and medium energies.
• AMEIs could receive better CNR results than MEIs.
• AMEIs at 40 keV potentially lower the stage migration of EGC.
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
Introduction
In clinical, therapeutic approach decisions depend on accurate preoperative staging. Early gastric cancer (EGC) can be treated with more limited surgeries, such as endoscopic mucosal resection (EMR) and laparoscopic surgery [1–3]. Preoperative chemotherapy or radiation therapy is usually recommended for advanced gastric cancer (AGC) to downstage the tumour and increase the chance for curative resection [4]. Currently, two-dimensional (2D) multi-detector computed tomography (MDCT) imaging using multiplanar reconstruction (MPR) has been widely used for the preoperative staging of gastric cancer because of the ability to detect the depth of tumour invasion and the presence or absence of metastasis [5–8]. However, its detection rates of EGC are unsatisfactory. For example, Makino et al. reported a detection rate of only 19 % using MDCT with MPR [6].
In the evaluation of EGC, the use of various three-dimensional (3D) reconstruction techniques, such as virtual gastroscopy, has led to improved diagnostic performance compared with conventional 2D imaging [9–13]. Nevertheless, one main disadvantage of 3D techniques is how time consuming they are. Although greater computer processing power makes more rapid reconstructions possible, the entire procedure takes approximately 20–30 minutes per patient [10]. Compared with 3D technologies, 2D imaging is more straightforward.
Dual-energy CT (DECT) can provide material decomposition information, especially iodine concentrations which could be used to analyse tumour perfusion and detect small iodine content lesions [14, 15]. DECT can also create “virtual” monochromatic images at a range of keV. Most previous studies have focused on CT angiography, which is significantly affected by the lower keV required to obtain image qualities with acceptable CNR and signal-to-noise ratio (SNR) or lower amount of contrast medium [16–18]. Few studies have investigated the effect of lower keV on tissue applications, particularly in hollow viscera, such as the stomach, because the enhancement on their walls is less concentrated than that observed in solid organ (e.g., liver). In addition, because the image noise usually increases even more than the iodine contrast at lower energy levels due to the absorption of lower-energy photons, the CNR might decrease at low keV. Thus, few applications employ lower keV (e.g., 40 keV or 50 keV) while simultaneously obtaining higher contrast and lower noise [19, 20].
A new prototype algorithm has been developed to calculate advanced monoenergetic images (AMEIs) (Dual energy Mono+, syngo IPIPE, Siemens Healthcare, Forchheim, Germany). As the prototype software has not been available for commercial use, it has been used for research purposes only in our institution. The purpose of this study was to explore the potential value of AMEIs in EGC.
Materials and methods
Patients
This retrospective study was approved by our institutional review board, and the requirement for informed consent was waived. From May to December 2013, 93 consecutive patients were pathologically confirmed to have EGC in our institution. A flowchart of the selection of these patients is presented in Fig. 1. The final study population consisted of 31 patients, including 19 men and 12 women, ranging in age from 38 to 81 years (mean ± standard deviation: 57.19 years ± 10.33). Mucosal tumours were found in 18 patients (58.06 %), and submucosal tumours in 13 (41.93 %), according to the Japanese Classification of Gastric Carcinoma [21].
CT examination
All 31 patients underwent CT after overnight fasting to empty the stomach. Before CT examinations, each patient drank 1000–1500 ml of tap water and was injected with 20 mg of scopolamine; they then underwent contrast-enhanced dual-energy CT (Siemens SOMATOM Definition Flash, Siemens Medical Solutions, Forchheim, Germany). CT scans were acquired with the tube voltages at 100 and 140 kV with a tin filter (i.e., 100/Sn140 kV), using reference mAs values of 230 and 178, respectively. The collimator was 32 × 0.6 mm, and the pitch was 0.6. All acquisitions were obtained with real-time tube current modulation (CARE Dose 4D, Siemens Medical Solutions). To estimate the time to peak enhancement of the celiac trunk, 16 ml contrast was first injected as a test bolus. Then the main bolus (1.5 ml iopromide per kilogram of body weight, Ultravist 370; Schering, Berlin, Germany) was injected at a rate of 3 ml/s. Three phasic, contrast-enhanced, dual-energy CT scans were performed on each patient, which included an arterial phase (AP) (determined by the time to peak enhancement of the celiac trunk) covering the whole stomach, a portal venous phase (PP) (20 s after the AP), ranging from the diaphragmatic domes to the anal verge, and a delayed phase (DEP) (150 s after the administration of contrast agents), covering the whole stomach. The mean scan delay time of AP was 15.10 ± 6.710 seconds (range, 6–28 seconds after injection), and the mean scan delay time of PP was 35.06 ± 6.673 seconds (range, 26–48 seconds after injection). For radiation dose, the mean CTDvol and DLP, which includes all phases, were 34.8 ± 7.1 mGy and 1080.5 ± 336.9 mGy · cm, respectively.
The DE raw data were reconstructed using a kernel of D30f. Three different series of images were generated: 100 kV images, Sn140 kV images, and mixed 120 kV PEIs, with a linear blending technique using a slice-thickness ratio of 0.5. Low 100 kV and high Sn140 kV images were then transferred to the workstation (Dual energy Monoenergetic, syngo MMWP, version 2008A; Siemens Healthcare, Forchheim, Germany) to generate six data sets of MEIs in 10-keV intervals (40-90 keV). Low 100 kV and high Sn140 kV images were also transferred to a personal computer with the prototype software (Dual Energy Mono+, Syngo IPIPE, Siemens Healthcare, Forchheim, Germany) to generate the six data sets of AMEIs in Dicom format with the same keV levels in 10 seconds for each patient in each scan phase. Then, all images were imported to the workstation and MPR images were also reconstructed, which were interpreted on the diagnostic monitors by radiologists. As the prototype software has not been available for commercial use, it has been used for research purposes only in our institution.
Image analysis
All images were evaluated by two abdominal radiologists (L.J.D. and Z.L.P), both with 10 years of experience in gastrointestinal imaging, who were completely blinded to the surgical and histological findings (they were aware that the patients had histologically proven gastric cancers, but completely blinded to lesion location, size, macroscopic features, and stage of the gastric cancers). Differences in assessment were resolved by consensus. The PEIs, 40–90 keV MEIs and AMEIs were anonymized and randomly assigned case numbers from 1 to 403. All data sets were randomly divided into 13 groups with 31 series of images per group. The two radiologists interpreted one group of images each time. To minimize recall bias, each reading session was separated by one week. The visibility and T staging of the tumours were evaluated on each series of CT images. The definitions used for T staging were summarized in Table 1 [22] (Fig. 2). The radiologists recorded the locations and sizes of the tumours. MDCT and pathologic findings regarding the locations and sizes of the gastric cancers were correlated by a third abdominal radiologist (C.S.) with 3 years of clinical experience. When the tumour was in the same location on the CT images as the pathology specimen and the tumour size measured from the CT images was approximately the same as the pathologic measurement, the tumour was defined as visible. The rates of stage migration were calculated. Taking the pathological results as the reference standard, different numbers of patients may be incorrectly staged by different reconstruction algorithms. Therefore, the incorrectly staged patients, including the invisible patients and over-staged patients, were considered as stage migration.
The two readers were asked to assess the contrast-to-noise ratio (CNR) of the lesion of each phase. Free-hand regions of interest (ROIs) were placed in the lesion and normal gastric wall to measure the attenuation values in Hounsfield units (HU). When the lesion was invisible, their attenuation was recorded as equal to the normal gastric wall. In addition, ROIs were placed in the psoas muscle to estimate the image noise. Subsequently, CNR was calculated using the following formula:
The readers were also asked to assess gastric-specific diagnostic confidence using a 5-point scale (1 = undiagnostic; 2 = will potentially miss lesions; 3 = will likely not miss or mischaracterize lesions; 4 = most likely will identify all abnormalities; 5 = can easily detect all lesions). Visual sharpness was graded on a 5-point scale (1 = unacceptable; 2 = poor; 3 = equivocal; 4 = good; 5 = excellent). Image noise was rated on a 4-point scale (1 = less than usual; 2 = optima [routine] noise; 3 = increased noise, does not affect interpretation; 4 = increased noise affecting interpretation).
Statistical analysis
Statistical analysis was performed using SPSS software (SPSS version 16.0, SPSS, Chicago, IL, USA). Continuous variables were expressed as the mean ± standard deviation. Ordinal variables are reported as median (range). Comparisons of all variables between MEIs, AMEIs and PEIs were performed. Comparisons of visibility and stage migration were performed using the McNemar test. Differences in CNR were estimated using a paired t-test. In addition, a Wilcoxon signed rank test was performed to compare gastric-specific diagnostic performance, image noise and visual sharpness. Box plots were used to visualize means, upper and lower extremes and upper and lower quartiles of CNR. p values were adjusted using the Adaptive False Discovery Rate method (SAS, version 9.2; SAS Institute, Gary, NC) as multiple comparisons were performed. A two-tailed p value of less than 0.05 was considered to indicate a statistically significant difference. To assess the degree of observer agreement, we used weighted kappa statistics. We considered a k value greater than 0.81 to be representative of almost perfect agreement and values of 0.61 to 0.80, 0.41 to 0.60, and less than 0.41 to be representative of substantial, moderate, and poor agreement, respectively.
Results
Pathology findings
EGCs can be divided into three macroscopic types [21]: I, protruding type; II, superficial type (IIa: elevated, IIb: flat, and IIc: depressed); and III, excavated type. According to the histological findings, two lesions were classified as protruding type, 19 lesions as superficial type (2 as IIa, 6 as IIb and 11 as IIc), and ten lesions as excavated type. By location, nine tumours occurred on the body, seven on the angle, and 15 on the antrum. The mean maximum diameter of the tumours was 1.74 ± 1.37 cm (range, 0.6–3.0 cm).
Visibility and stage migration of the primary tumour
The visibility and stage migration values are summarized in Table 2. Visibility was significant higher for AMEIs at 40 keV (AM40 keV) compared with MEIs at 40 keV (M40 keV), 50 keV (M50 keV), and 60 keV (M60 keV) (p = 0.008, 0.008, and 0.045, respectively). There were no significant differences between AM40 keV and the other MEIs and PEIs (all p > 0.05). M40 keV and M50 keV showed significantly worse visibility than the other MEIs or PEIs, with the exception of M60 keV. The rate of stage migration was significantly lower for AM40 keV compared with other AMEIs, MEIs and PEIs (all p < 0.05), with the exception of AM50 keV, AM60 keV and AM70 keV (p = 0.250, 0.083 and 0.064, respectively). In addition, only AM40 keV showed a significantly lower stage migration compared with the PEIs (p = 0.026). (Details are provided in “Supplementary Information”.)
Twenty-five lesions from 31 patients were visible on AM40 keV data sets. Of these 25 lesions, five (16.1 %) lesions showed focal enhancement in AP, and 23 (74.2 %) showed strong enhancement in PP (with three lesions showing abnormal, strong enhancement in both AP and PP), with or without mural thickening. Twenty lesions were visible on PEIs. Among them, five lesions (16.1 %) showed focal enhancement in AP, and 18 lesions (58.1 %) showed strong enhancement in PP (with three lesions showing abnormal, strong enhancement in both AP and PP), with or without mural thickening. All visible lesions became indistinct in DEP. Five extra lesions, including four superficial type lesions and one excavated type lesion, were observed with AM40 keV, in contrast to the results observed with PEIs. All of these lesions showed strong enhancement of the inner hyperattenuating layer in PP and were invisible on PEIs (Figs. 3 and 4). Compared with AM40 keV, three more lesions, including two excavated type and one superficial-depressed-type lesions, were over-staged by PEIs (Figs. 5 and 6).
Objective image analysis
The CNR results are listed in Fig. 7. The CNR-AP (CNR of the AP) and CNR-PP (CNR of the PP) of AM40 keV were significantly higher than for any other AMEIs, MEIs or PEIs (CNR-AP: 3.6 ± 3.0; CNR-PP: 4.4 ± 3.5; all p < 0.05). With regard to CNR-DEP (CNR of DEP), AM40 keV achieved the highest value, which was significantly different from those of the other AMEIs, MEIs, and PEIs (all p < 0.05) except for AM50 keV (p = 0.083). CNR-AP and CNR-PP for M40 keV and M50 keV were the lowest and were significantly different from those of other MEIs and PEIs (all p < 0.05). The CNR-AP and CNR-PP were significantly higher than CNR-DEP of AM40 keV (p = 0.034 and < 0.001, respectively). However, no significant difference was observed between CNR-AP and CNR-PP (p = 0.103). (Details are provided in “Supplementary Information”.)
Subjective image analysis
Table 3 summarizes the subjective results for the MEIs, AMEIs and PEIs. AM40 keV gave a significantly higher gastric-specific diagnostic performance and visual sharpness compared with other AMEIs, MEIs and PEIs (all p < 0.05). With respect to image noise, PEIs had significant less noise compared with AMEIs and MEIs (all p < 0.05). M40 keV, M50 keV, and M60 keV had significantly higher image noise than did the other MEIs. The mean scores of image noise were acceptable for AM40 keV, AM50 keV, AM60 keV, AM70 keV, M70 keV and M80 keV. (Details are provided in “Supplementary Information”.)
Inter-observer agreement
There is disagreement between two reviewers for the independent readings. The weighted k values of the visibility and over-staging were 0.806 and 0.734 (both p < 0.001), respectively. There was excellent inter-observer agreement with respect to the subjective image quality (k = 0.906 for gastric-specific diagnostic confidence, k = 0.922 for visual sharpness, and k = 0.891 for image noise, respectively) (all p < 0.001).
Discussion
A previous study demonstrated that MEIs at 70 keV provided subjectively improved image qualities compared with PEIs in the evaluation of hepatic metastases [23], and that MEIs at 100 keV could significantly reduce dark-band-like artefacts, making it possible to evaluate the condition of bone-encircling dental implant bodies [24]. Nevertheless, few studies to date have investigated the application of MEIs or AMEIs to the stomach. Our study used the Mono+ algorithm to increase the CNR and decrease image noise at a low keV, and the results indicated that AM40 keV had the highest overall score: it resulted in significantly better visibility than M40 keV, M50 keV and M60 keV and showed a statistically significant lower stage migration than PEIs; it also had the highest CNR-AP, CNR-PP, and CNR-DEP, consistent with the gastric-specific diagnostic performance and visual sharpness results.
Although MEIs provides several benefits, such as increased signal of contrast agent and the possibility to reduce beam hardening, it carries the main drawback of a substantial increase in image noise at lower keVs. Thus, the gain in CNR with monoenergetic imaging, compared with a PEIs, or a single-energy scan at optimal kV is limited. To obtain better CNR results, a frequency-based recombination of the low-keV images (which contain high iodine contrast) and medium energies (typically approximately 70 keV, which received superior noise properties) was performed to combine the benefits of both stacks—the improved contrast and low noise [25]. Grant et al. investigated different image sets of phantoms to assess MEIs and AMEIs. Their results found out that the Mono+ algorithm provides the optimum iodine CNR at the lowest energy level of 40 keV [25]. As applied in our study, Mono+ increased the visibility of EGC with AM40 keV to 80.7 % on 2D and MPR images.
EGC, a hypervascular neoplasm [11], is often detected as areas of prominent contrast enhancement without mural thickening [26, 27]. Further, most EGCs are often not detected on PEIs because of the insufficient enhancement of focal lesions compared with the normal surrounding stomach walls. The incidence of EGCs with intense focal enhancement was 47 % [28]. In our PEIs data sets, 58.1 % of the lesions showed focal enhancement in PP, whereas 74.2 % of the lesions showed focal enhancement in the AM40 keV images. This result could be attributed to two factors: the scan protocol and the Mono+ algorithm. Because we used test bolus technique to individualize the scan delay time and achieve optimal contrast opacify [29], the PP, which corresponds to the arterial or mucosal phase scan time of previous reports [26], more accurately displayed the gastric mucosa for each patient, resulting in better detection of abnormal mucosal changes.
Because of the ability of the Mono+ algorithm to increase the lesion CNR, more lesions were visible on AM40 keV. Our AM40 keV data sets were able to reveal 25 lesions in 31 patients. Although the visibility of EGC in a CT scan is strongly influenced by its morphological type and elevated-type EGCs are easier to detect than superficial or depressed-type cancers, five extra lesions, including four superficial-type lesions and one excavated-type lesion, were shown in AM40 keV images compared with PEIs. All of these lesions showed strong enhancement of the inner hyperattenuating layer in PP, which were invisible on PEIs. AM40 keV has higher CNR-APs and CNR-PPs than any other AMEIs, MEIs and PEIs. Because our CNR results were calculated using the contrast between gastric lesions and normal gastric wall, a higher CNR may lead to a better image of the lesions. Thus, we believe that EGCs that are invisible (i.e., superficial-type or excavated-type) using conventional CT could be depicted more clearly using AM40 keV. The same applies to the decreased stage migration in AM40 keV images compared to PEIs.
The decreased stage migration in AM40 keV images compared with PEIs, which over-staged an additional three lesions, including two excavated-type lesions and one superficial-depressed-type lesion, indicating a clearer depiction of EGCs. The most reliable diagnostic criterion for differentiating EGC from AGC at MDCT is a good visualization of the low-attenuation-strip outer layer of the gastric wall [11]; however, defining the depth of tumour invasion in cases of T1b was usually difficult because the low-attenuation-strip outer layer was obscured. This might be due to the thinning of the gastric wall related to distension or inflammation or oedema in the muscular layer beneath the primary lesion. Therefore, we often need to distinguish T1b tumours from T2 or even T3 tumours. Our study revealed that AM40 keV could stage EGC more correctly than PEIs (20 vs. 12), owing to the clear depiction of the gastric wall using the Mono+ algorithm, which indicated a better discrimination of T1b tumours from more advance tumours.
Conventional lower-energy techniques result in increased image noise via increased quantum mottle. Consistent with this finding, M40 keV, M50 keV and M60 keV showed statistically higher image noise score, which affected the diagnostic interpretation. Using the Mono+ algorithm, the noise in the AM40 keV images was significantly decreased compared with M40 keV, M50 keV and M60 keV and did not affect the diagnostic interpretation. In short, dual-energy scan with dual-source CT of the stomach is feasible in routine clinical practice, and AMEIs at 40 keV can decrease the stage migration of EGC.
One limitation of our study was its small number of patients, which introduces the potential for unintended biases. Further research using a larger patient population is necessary. In addition, even though the principle of the design in this study is randomization and double-blind, there are still unintentional biases in the study involving subjective judgements. Furthermore, we only compared the 2D axial and MPR images for three types of image data sets. The detection and stage results of 3D reconstruction such as virtual endoscopy based on AMEIs data sets could be investigated in a future study.
In conclusion, 2D advanced image-based calculated virtual 40 keV images with MPR significantly increase the CNR of EGC, leading to significantly decreased stage migration of EGC.
Abbreviations
- EGC:
-
Early gastric cancer
- MPR:
-
Multiplanar reconstruction
- 2D:
-
Two-dimensional
- 3D:
-
Three-dimensional
- kV:
-
Kilovoltage
- keV:
-
Kiloelectron volt
- PEIs:
-
Polyenergetic images
- MEIs:
-
Monoenergetic images
- AMEIs:
-
Advanced monoenergetic images
- AP:
-
Arterial phase
- PP:
-
Portal venous phase
- DEP:
-
Delayed phase
References
Lian J, Chen S, Zhang Y, Qiu F (2012) A meta-analysis of endoscopic submucosal dissection and EMR for early gastric cancer. Gastrointest Endosc 76:763–770
Gotoda T, Jung HY (2013) Endoscopic resection (endoscopic mucosal resection/ endoscopic submucosal dissection) for early gastric cancer. Dig Endosc 25:55–63
Takahashi T, Saikawa Y, Kitagawa Y (2013) Gastric cancer: current status of diagnosis and treatment. Cancers 5:48–63
Yoshikawa T, Sasako M, Yamamoto S et al (2009) Phase II study of neoadjuvant chemotherapy and extended surgery for locally advanced gastric cancer. Br J Surg 96:1015–1022
Yan C, Zhu ZG, Yan M et al (2009) Value of multidetector‐row computed tomography in the preoperative T and N staging of gastric carcinoma: A large‐scale Chinese study. J Surg Oncol 100:205–214
Makino T, Fujiwara Y, Takiguchi S et al (2011) Preoperative T staging of gastric cancer by multi-detector row computed tomography. Surgery 149:672–679
Shimizu K, Ito K, Matsunaga N, Shimizu A, Kawakami Y (2005) Diagnosis of gastric cancer with MDCT using the water-filling method and multiplanar reconstruction: CT–histologic correlation. Am J Roentgenol 185:1152–1158
Woo S, Kim S, Kim T et al (2008) Investigation of the association between CT detection of early gastric cancer and ultimate histology. Clin Radiol 63:1236–1244
Kim HJ, Kim AY, Oh ST et al (2005) Gastric Cancer Staging at Multi–Detector Row CT Gastrography: Comparison of Transverse and Volumetric CT Scanning 1. Radiology 236:879–885
Kim JH, Eun HW, Goo DE, Shim CS, Auh YH (2006) Imaging of Various Gastric Lesions with 2D MPR and CT Gastrography Performed with Multidetector CT1. Radiographics 26:1101–1116
Chen C-Y, Hsu J-S, Wu D-C et al (2007) Gastric Cancer: Preoperative Local Staging with 3D Multi–Detector Row CT—Correlation with Surgical and Histopathologic Results 1. Radiology 242:472–482
Kim JH, Eun HW, Hong SS, Kim YJ, Han JK, Choi BI (2012) Gastric cancer detection using MDCT compared with 2D axial CT: diagnostic accuracy of three different reconstruction techniques. Abdom Imaging 37:541–548
Park HS, Lee JM, Kim SH et al (2010) Three-dimensional MDCT for preoperative local staging of gastric cancer using gas and water distention methods: a retrospective cohort study. AJR Am J Roentgenol 195:1316–1323
Thaiss WM, Haberland U, Kaufmann S et al (2015) Iodine concentration as a perfusion surrogate marker in oncology: Further elucidation of the underlying mechanisms using Volume Perfusion CT with 80 kVp. Eur Radiol. doi:10.1007/s00330-015-4154-9
Marin D, Pratts-Emanuelli JJ, Mileto A et al (2015) Interdependencies of acquisition, detection, and reconstruction techniques on the accuracy of iodine quantification in varying patient sizes employing dual-energy CT. Eur Radiol 25:679–686
Wan Y, Li Z, Ji N, Gao J (2014) Comparison of gastric vascular anatomy by monochromatic and polychromatic dual-energy spectral computed tomography imaging. J Int Med Res 42:26–34
Sudarski S, Apfaltrer P (2013) Optimization of keV-settings in abdominal and lower extremity dual-source dual-energy CT angiography determined with virtual monoenergetic imaging. Eur J Radiol 82:e574–e581
Apfaltrer P, Sudarski S, Schneider D et al (2014) Value of monoenergetic low-kV dual energy CT datasets for improved image quality of CT pulmonary angiography. Eur J Radiol 83:322–328
Yu L, Leng S, McCollough CH (2012) Dual-energy CT–based monochromatic imaging. Am J Roentgenol 199:S9–S15
Delesalle MA, Pontana F, Duhamel A et al (2013) Spectral optimization of chest CT angiography with reduced iodine load: experience in 80 patients evaluated with dual-source, dual-energy CT. Radiology 267:256–266
Association JGC (2011) Japanese classification of gastric carcinoma: 3rd English edition. Gastric Cancer: Off J Int Gastric Cancer Assoc Jpn Gastric Cancer Assoc 14:101
Kim JW, Shin SS, Heo SH et al (2012) Diagnostic performance of 64-section CT using CT gastrography in preoperative T staging of gastric cancer according to 7th edition of AJCC cancer staging manual. Eur Radiol 22:654–662
Sudarski S, Apfaltrer P, Nance JW Jr et al (2014) Objective and Subjective Image Quality of Liver Parenchyma and Hepatic Metastases with Virtual Monoenergetic Dual-source Dual-energy CT Reconstructions: An Analysis in Patients with Gastrointestinal Stromal Tumor. Acad Radiol 21:514–522
Tanaka R, Hayashi T, Ike M, Noto Y, Goto TK (2013) Reduction of dark-band-like metal artifacts caused by dental implant bodies using hypothetical monoenergetic imaging after dual-energy computed tomography. Oral Surg Oral Med Oral Pathol Oral Radiol 115:833–838
Grant KL, Flohr TG, Krauss B, Sedlmair M, Thomas C, Schmidt B (2014) Assessment of an Advanced Image-Based Technique to Calculate Virtual Monoenergetic Computed Tomographic Images From a Dual-Energy Examination to Improve Contrast-To-Noise Ratio in Examinations Using Iodinated Contrast Media. Investig Radiol. doi:10.1097/rli.0000000000000060
Lee JH, Jeong YK, Kim DH et al (2000) Two-phase helical CT for detection of early gastric carcinoma: importance of the mucosal phase for analysis of the abnormal mucosal layer. J Comput Assist Tomogr 24:777–782
Kim H, Han H, Choi J et al (2001) Preoperative evaluation of gastric cancer: value of spiral CT during gastric arteriography (CTGA). Abdom Imaging 26:123–130
Lee IJ, Lee JM, Kim SH et al (2010) Diagnostic performance of 64-channel multidetector CT in the evaluation of gastric cancer: differentiation of mucosal cancer (T1a) from submucosal involvement (T1b and T2). Radiology 255:805–814
Rodrigues J, Mathias H, Negus I, Manghat N, Hamilton M (2012) Intravenous contrast medium administration at 128 multidetector row CT pulmonary angiography: Bolus tracking versus test bolus and the implications for diagnostic quality and effective dose. Clin Radiol 67:1053–1060
Acknowledgments
The scientific guarantor of this publication is Fuhua Yan. The authors of this manuscript declare relationships with the following companies: Siemens Medical System. The authors of this manuscript declare no relationships with Siemens Medical System, whose products or services are related to the subject matter of the article. This study has received funding by Shanghai science and technology development (No. 134119a5900), Medical Engineer cross subject of Jiao Tong University (No.YG2012MS48), NSFC (No. 81171312), and NSFC (No.U1532107).
Baisong Wang kindly provided statistical advice for this manuscript. Institutional Review Board approval was obtained. Written informed consent was waived by the Institutional Review Board. No study subjects or cohorts have been previously reported. Methodology: retrospective, diagnostic study, performed at one institution.
Author information
Authors and Affiliations
Corresponding author
Electronic supplementary material
Below is the link to the electronic supplementary material.
ESM 1
(DOC 177 kb)
Rights and permissions
Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
About this article
Cite this article
Shi, C., Zhang, H., Yan, J. et al. Decreased stage migration rate of early gastric cancer with a new reconstruction algorithm using dual-energy CT images: a preliminary study. Eur Radiol 27, 671–680 (2017). https://doi.org/10.1007/s00330-016-4442-z
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00330-016-4442-z