Abstract

Objectives

This study evaluated the potential of three-tesla diffusion tensor imaging (DTI) and tractography to detect changes of the radial (RN) and median (MN) nerves during transient upper arm compression by a silicon ring tourniquet.

Methods

Axial T2-weighted and DTI sequences (b = 700 s/mm2, 16 gradient encoding directions) of 13 healthy volunteers were obtained. Fractional anisotropy (FA) and apparent diffusion coefficient (ADC) values of the MN and RN were measured at the spiral groove and further visualized in 3D by deterministic tractography (thresholds: FA = .15, angle change = 27°).

Results

Local/lesional RN FA values increased (p = 0.001) and ADC values decreased (p = 0.02) during a 20-min upper arm compression, whereas no significant FA (p = 0.49) or ADC (p = 0.73) changes of the MN were detected. There were no T2-w nerve signal changes or alterations of nerve trajectories in 3D.

Conclusions

Acute nerve compression of the RN leads to changes of its three-tesla DTI metrics. Peripheral nerve DTI provides non-invasive insights into the “selective” vulnerability of the RN at the spiral groove.

Key Points

• DTI-based neurography detects nerve changes during acute nerve compression.

• Compression leads to a transient increase in local radial nerve FA values.

• DTI provides insights into radial nerve vulnerability at the spiral groove.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

Abbreviations

ADC:

Apparent diffusion coefficient

aSNR:

Approximate signal-to-noise ratio

EMG:

Electromyography

FA:

Fractional anisotropy

MIP:

Maximum intensity projection

MN:

Median nerve

ROI:

Region of interest

RN:

Radial nerve

T2-w:

T2-weighted

References

  1. Chhabra A, Deune GE, Murano E, Prince JL, Soldatos T, Flammang A (2012) Advanced MR neurography imaging of radial nerve entrapment at the spiral groove: a case report. J Reconstr Microsurg 28:263–266

    Article  PubMed  Google Scholar 

  2. Aho K, Sainio K, Kianta M, Varpanen E (1983) Pneumatic tourniquet paralysis. Case report. J Bone Joint Surg Brit 65:441–443

    CAS  PubMed  Google Scholar 

  3. Linda DD, Harish S, Stewart BG, Finlay K, Parasu N, Rebello RP (2010) Multimodality imaging of peripheral neuropathies of the upper limb and brachial plexus. Radiographics 30:1373–1400

    Article  PubMed  Google Scholar 

  4. Willmott AD, White C, Dukelow SP (2012) Fibrillation potential onset in peripheral nerve injury. Muscle Nerve 46:332–340

    Article  PubMed  Google Scholar 

  5. Hiltunen J, Suortti T, Arvela S, Seppa M, Joensuu R, Hari R (2005) Diffusion tensor imaging and tractography of distal peripheral nerves at 3 T. Clin Neurophysiol 116:2315–2323

    Article  PubMed  Google Scholar 

  6. Takagi T, Nakamura M, Yamada M et al (2009) Visualization of peripheral nerve degeneration and regeneration: monitoring with diffusion tensor tractography. Neuroimage 44:884–892

    Article  PubMed  Google Scholar 

  7. Khalil C, Hancart C, Le Thuc V, Chantelot C, Chechin D, Cotten A (2008) Diffusion tensor imaging and tractography of the median nerve in carpal tunnel syndrome: preliminary results. Eur Radiol 18:2283–2291

    Article  CAS  PubMed  Google Scholar 

  8. Guggenberger R, Markovic D, Eppenberger P et al (2012) Assessment of median nerve with MR neurography by using diffusion-tensor imaging: normative and pathologic diffusion values. Radiology 265:194–203

    Article  PubMed  Google Scholar 

  9. Bäumer P, Pham M, Ruetters M et al (2014) Peripheral neuropathy: Detection with diffusion-tensor imaging radiology. Radiology 273:185–193

    Article  PubMed  Google Scholar 

  10. Ladenheim E, Krauthammer J, Agrawal S, Lum C, Chadwick N (2013) A sterile elastic exsanguination tourniquet is effective in preventing blood loss during hemodialysis access surgery. J Vasc Access 14:116–119

    Article  PubMed  Google Scholar 

  11. Dietrich O, Raya JG, Reeder SB, Reiser MF, Schoenberg SO (2007) Measurement of signal-to-noise ratios in MR images: influence of multichannel coils, parallel imaging, and reconstruction filters. J Magn Reson Imaging 26:375–385

    Article  PubMed  Google Scholar 

  12. Guggenberger R, Eppenberger P, Markovic D et al (2012) MR neurography of the median nerve at 3.0 T: optimization of diffusion tensor imaging and fiber tractography. Eur J Radiol 81:e775–e782

    Article  PubMed  Google Scholar 

  13. Kim B, Srinivasan A, Sabb B, Feldman EL, Pop-Busui R (2014) Diffusion tensor imaging of the sural nerve in normal controls. Clin Imaging 38:648–654

    Article  PubMed  Google Scholar 

  14. Rempel D, Dahlin L, Lundborg G (1999) Pathophysiology of nerve compression syndromes: response of peripheral nerves to loading. J Bone Joint Surg Am 81:1600–1610

    CAS  PubMed  Google Scholar 

  15. Bäumer P, Dombert T, Staub F et al (2011) Ulnar neuropathy at the elbow: MR neurography - nerve T2 signal increase and caliber. Radiology 260:199–206

    Article  PubMed  Google Scholar 

Download references

Acknowledgements

The scientific guarantor of this publication is Univ. Prof. Dr. Daniela Prayer. The authors of this manuscript declare no relationships with any companies, whose products or services may be related to the subject matter of the article. The authors state that this work has not received any funding. Dr. Michael Weber kindly provided statistical advice for this manuscript. Institutional Review Board approval was obtained. Written informed consent was obtained from all subjects (patients) in this study. Methodology: prospective, case-control study, performed at one institution.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Gregor Kasprian.

Electronic supplementary material

Below is the link to the electronic supplementary material.

ESM 1

(JPEG 396 kb)

ESM 2

(JPEG 292 kb)

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Jengojan, S., Kovar, F., Breitenseher, J. et al. Acute radial nerve entrapment at the spiral groove: detection by DTI-based neurography. Eur Radiol 25, 1678–1683 (2015). https://doi.org/10.1007/s00330-014-3562-6

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00330-014-3562-6

Keywords

Navigation