Intrinsic respiratory gating in small-animal CT

  • Experimental
  • Published:
European Radiology Aims and scope Submit manuscript

Abstract

Gating in small-animal CT imaging can compensate artefacts caused by physiological motion during scanning. However, all published gating approaches for small animals rely on additional hardware to derive the gating signals. In contrast, in this study a novel method of intrinsic respiratory gating of rodents was developed and tested for mice (n=5), rats (n=5) and rabbits (n=2) in a flat-panel cone-beam CT system. In a consensus read image quality was compared with that of non-gated and retrospective extrinsically gated scans performed using a pneumatic cushion. In comparison to non-gated images, image quality improved significantly using intrinsic and extrinsic gating. Delineation of diaphragm and lung structure improved in all animals. Image quality of intrinsically gated CT was judged to be equivalent to extrinsically gated ones. Additionally 4D datasets were calculated using both gating methods. Values for expiratory, inspiratory and tidal lung volumes determined with the two gating methods were comparable and correlated well with values known from the literature. We could show that intrinsic respiratory gating in rodents makes additional gating hardware and preparatory efforts superfluous. This method improves image quality and allows derivation of functional data. Therefore it bears the potential to find wide applications in small-animal CT imaging.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5

Similar content being viewed by others

References

  1. Buliev IG, Badea CT, Kolitsi Z, Pallikarakis N (2003) Estimation of the heart respiratory motion with applications for cone beam computed tomography imaging: a simulation study. IEEE Trans Inf Technol Biomed 7:404–411

    Article  PubMed  Google Scholar 

  2. Cody DD, Nelson CL, Bradley WM, Wislez M, Juroske D, Price RE, Zhou X, Bekele BN, Kurie JM (2004) Murine lung tumor measurement using respiratory-gated micro-computed tomography. Invest Radiol 40:263–269

    Article  Google Scholar 

  3. Walters EB, Panda K, Bankson JA, Brown E, Cody DD (2004) Improved method of in vivo respiratory-gated micro-CT imaging. Phys Med Biol 49:4163–4172

    Article  PubMed  Google Scholar 

  4. Ford NL, Nikolov HN, Norley CJ, Thornton MM, Foster PJ, Drangova M, Holdsworth DW (2005) Prospective respiratory-gated micro-CT of free breathing rodents. Med Phys 32:2888–2898

    Article  PubMed  Google Scholar 

  5. Hu J, Haworth ST, Molthen RC, Dawson CA (2004) Dynamic small animal lung imaging via a postacquisition respiratory gating technique using micro-cone beam computed tomography. Acad Radiol 11:961–970

    Article  PubMed  Google Scholar 

  6. Drangova M, Ford NL, Detombe SA, Wheatley AR, Holdsworth DW (2007) Fast retrospectively gated quantitative four-dimensional (4D) cardiac micro computed tomography imaging of free-breathing mice. Invest Radiol 42:85–94

    Article  PubMed  Google Scholar 

  7. Bartling S, Stiller W, Grasruck M, Schmidt B, Peschke P, Semmler W, Kiessling F (2007) Retrospective motion-gating in small animal CT of mice and rats. Invest Radiol 42:704–714

    Article  PubMed  Google Scholar 

  8. Kiessling F, Greschus S, Lichy MP, Bock M, Fink C, Vosseler S, Moll J, Mueller MM, Fusenig NE, Traupe H, Semmler W (2004) Volumetric computed tomography (VCT): a new technology for noninvasive, high-resolution monitoring of tumor angiogenesis. Nat Med 10:1133–1138

    Article  CAS  PubMed  Google Scholar 

  9. Zaporozhan J, Ley S, Unterhinninghofen R, Saito Y, Fabel-Schulte M, Keller S, Szabo G, Kauczor HU (2006) Free-breathing. -dimensional computed tomography of the lung using prospective respiratory gating: charge-coupled device camera and laser sensor device in an animal experiment. Invest Radiol 41:468–475

    Article  PubMed  Google Scholar 

  10. Ritchie CJ, Hsieh J, Gard MF, Godwin JD, Kim Y, Crawford CR (1994) Predictive respiratory gating: a new method to reduce motion artifacts on CT scans. Radiology 190:847–852

    CAS  PubMed  Google Scholar 

  11. Kachelrieß M, Sennst DA, Maxlmoser W, Kalender WA (2002) Kymogram detection and kymogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart. Med Phys 29:1489–1503

    Article  PubMed  Google Scholar 

  12. Manzke R, Kohler T, Nielsen T, Hawkes D, Grass M (2004) Automatic phase determination for retrospectively gated cardiac CT. Med Phys 31:3345–3362

    Article  CAS  PubMed  Google Scholar 

  13. Sonke JJ, Zijp L, Remeijer P, van Herk M (2005) Respiratory correlated cone beam CT. Med Phys 32:1176–1186

    Article  PubMed  Google Scholar 

  14. Zeng R, Fessler JA, Balter JM (2005) Respiratory motion estimation from slowly rotating x-ray projections: theory and simulation. Med Phys 32:984–991

    Article  PubMed  Google Scholar 

  15. Gupta R, Grasruck M, Suess C, Bartling SH, Schmidt B, Stierstorfer K, Popescu S, Brady T, Flohr T (2006) Ultra-high resolution flat-panel volume CT: fundamental principles, design architecture, and system characterization. Eur Radiol 30:337–343

    Google Scholar 

  16. Feldkamp LA, Davis LC, Kress JW (1984) Practical cone-beam algorithm. J Opt Soc Am 1:612–619

    Article  Google Scholar 

  17. Bartling S, Stiller W, Semmler W, Kiessling F (2007) Small animal Computed Tomography Imaging. CMIR 3:45–59

    Google Scholar 

  18. Wolf I, Vetter M, Wegner I, Bottger T, Nolden M, Schobinger M, Hastenteufel M, Kunert T, Meinzer HP (2004) The medical imaging interaction toolkit(MITK): a toolkit facilitating the creation of interactive software by extending VTK and ITK. Proceedings of SPIE 5367:16–27

    Article  Google Scholar 

  19. De Man B, Edic P, Basu S (2005) An iterative algorithm for time-resolved reconstruction of a CT scan of a beating heart. Proceedings of Fully 3D, The 8th international meeting on fully three-dimensional image reconstruction in radiology and nuclear medicine: pp 356–359

  20. Mai W, Badea CT, Wheeler CT, Hedlund LW, Johnson GA (2005) Effects of breathing and cardiac motion on spatial resolution in the microscopic imaging of rodents. Magn Reson Med 53:858–665

    Article  PubMed  Google Scholar 

  21. Sharp P, La Regina M, LaRegina M (1998) The Laboratory Rat. CRC Press, Boca Raton, FL, USA

    Google Scholar 

  22. Krause MF, Hoehn T (1999) Decrease in lung volume depends on end-expiratory pressure in a rabbit model of airway lavage. Respiration 66:259–264

    Article  CAS  PubMed  Google Scholar 

  23. Zhu GF, Zhang W, Zong H, Liang Y (2006) Effects of continuous tracheal gas insufflation during pressure limited ventilation on pulmonary surfactant in rabbits with acute lung injury. Chin Med J (Engl) 119:1415–1420

    Google Scholar 

Download references

Acknowledgment

The work was supported by the trans-regional grant “Vascular Differentiation and Remodelling” of the German Research Foundation (DFG). We thank Karin Leotta for her excellent technical assistance during data acquisition and post processing.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Soenke H. Bartling.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Bartling, S.H., Dinkel, J., Stiller, W. et al. Intrinsic respiratory gating in small-animal CT. Eur Radiol 18, 1375–1384 (2008). https://doi.org/10.1007/s00330-008-0903-3

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00330-008-0903-3

Keywords

Navigation