Abstract
The aim of the study was to evaluate prospectively the technical feasibility and discomfort of two different injection techniques for MR arthrography of the hip. Sixty-one consecutive patients undergoing MR arthrography of the hip (68 hips) were randomly injected either at the femoral head (36 hips) or the femoral neck (32 hips). The patients rated discomfort during and 0–72 h after arthrography using a visual analogue scale (VAS, 0=“did not feel anything”, 100=“unbearable”). The volume injected, the distance between the needle tract and the neurovascular bundle, the duration of the procedure and the extra-articular contrast leakage were measured. No significant differences were found for the volume injected, the distance between the needle tract and the neurovascular bundle, or the procedure duration. Volume of extra-articular contrast leakage was statistically significantly different (head 1±2 cm3, neck 3±5 cm3, P=0.024). The VAS score for needle advancement was significantly different (head 25±20, neck 19±23, P=0.031). No significant differences were found for the VAS score regarding delayed discomfort. Before the examination the arthrography-related discomfort was overestimated by 74% (50/68), correctly anticipated by 22% (15/68) and underestimated by 4% (3/68) of the patients. MR-related discomfort was overestimated by 32% (22/68), correctly anticipated by 57% (39/68) and underestimated by 10% (7/68) of the patients. Both hip puncture techniques were well tolerated. The neck injection technique produced less discomfort and was associated with greater extra-articular contrast leakage.
Similar content being viewed by others
References
Kenin A, Levine J (1952) A technique for arthrography of the hip. Am J Roentgenol Radium Ther Nucl Med 68:107–111
Straw R, Chell J, Dhar S (2002) Adduction sign in pediatric hip arthrography. J Pediatr Orthop 22:350–351
Strife JL, Towbin R, Crawford A (1984) Hip arthrography in infants and children: the inferomedial approach. Radiology 152:536
Schwartz AM, Goldberg MJ (1979) The medial adductor approach to arthrography of the hip in children. Radiology 132:483
Leopold SS, Battista V, Oliverio JA (2001) Safety and efficacy of intraarticular hip injection using anatomic landmarks. Clin Orthop 192–197
Hendrix RW, Anderson TM (1981) Arthrographic and radiologic evaluation of prosthetic joints. Radiol Clin North Am 19:349–364
Bellaiche L, Wybier M, Champsaur P (1997) Arthrography of the hip. Ann Radiol (Paris) 40:11–21
Kilcoyne RF, Kaplan P (1992) The lateral approach for hip arthrography. Skeletal Radiol 21:239–240
Aliabadi P, Baker ND, Jaramillo D (1998) Hip arthrography, aspiration, block, and bursography. Radiol Clin North Am 36:673–690
Salvati EA, Freiberger RH, Wilson PD Jr (1971) Arthrography for complications of total hip replacement. A review of thirty-one arthrograms. J Bone Joint Surg Am 53:701–709
Ozonoff MB (1973) Controlled arthrography of the hip: a technique of fluoroscopic monitoring and recording. Clin Orthop 93:260–264
Miller TT (2000) MR arthrography of the shoulder and hip after fluoroscopic landmarking. Skeletal Radiol 29:81–84
Goldman AB (1980) Arthrography of the hip joint. Crit Rev Diagn Imaging 13:111–171
Spector GW (1973) Joint distention arthrography. Alternate method of treatment of osteoarthritis of the hip. Mo Med 70:605–607 passim
Brandser EA, El-Khoury GY, FitzRandolph RL (1997) Modified technique for fluid aspiration from the hip in patients with prosthetic hips. Radiology 204:580–582
Razzano CD, Nelson CL, Wilde AH (1974) Arthrography of the adult hip. Clin Orthop 99:86–94
Dobson MM (1950) A further anatomical check on the accuracy of intra-articular hip injections in relation to the therapy of coxarthritis. Ann Rheum Dis 9:237–240
Ganz R, Parvizi J, Beck M, Leunig M, Notzli H, Siebenrock KA (2003) Femoroacetabular impingement: a cause for osteoarthritis of the hip. Clin Orthop 417:112–120
Ganz R, Gill TJ, Gautier E, Ganz K, Krugel N, Berlemann U (2001) Surgical dislocation of the adult hip: a technique with full access to the femoral head and acetabulum without the risk of avascular necrosis. J Bone Joint Surg Br 83:1119–1124
Elentuck D, Palmer WE (2004) Direct magnetic resonance arthrography. Eur Radiol 14:1956–1967
Hewitt JD, Glisson RR, Guilak F, Vail TP (2002) The mechanical properties of the human hip capsule ligaments. J Arthroplasty 17:82–89
Binkert CA, Zanetti M, Hodler J (2001) Patients’ assessment of discomfort during MR arthrography of the shoulder. Radiology 221:775–778
Robbins MI, Anzilotti KF Jr, Katz LD, Lange RC (2000) Patient perception of magnetic resonance arthrography. Skeletal Radiol 29:265–269
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Duc, S.R., Hodler, J., Schmid, M.R. et al. Prospective evaluation of two different injection techniques for MR arthrography of the hip. Eur Radiol 16, 473–478 (2006). https://doi.org/10.1007/s00330-005-2865-z
Received:
Revised:
Accepted:
Published:
Issue Date: