Abstract
The purpose of this study was to analyze the effect of various tube current settings (mAs) and optimize the image quality and dose for adult cranial CT protocol. Sixty adult patients who underwent a cranial CT scanning for different indications were subdivided into three subgroups. Subjective image and noise quality scores and quantitative noise measurements were selectively studied on three reference levels (cerebellar, basal ganglia and centrum semiovale levels). For each subgroup, only one level was studied. Head circumference (HC) and the maximum anteroposterior diameter (MAPD) of each patient were measured. At 50% decreased dose protocol, there was no poor quality score at any level. At nearly 60% decreased dose protocol, the incidence of poor quality scores was much higher at the cerebellar level than at the other two levels. For the same protocol number, quantitative noise measurements were higher at the cerebellar level than the other two supratentorial levels. The correlation was found to be significant between HC, MAPD and quantitative noise measurements, and there was a non-significant correlation between HC and subjective noise scores. In adult cranial CT, depending on the level, a dose reduction of up to 60% may be possible while maintaining image quality.
Similar content being viewed by others
References
van Unnik J, Broerse JJ, Geleijns J, Jansen JT, Zoetelief J, Zweers D (1997) Survey of CT techniques and absorbed dose in various Dutch hospitals. Br J Radiol 70:367–371
Wade JP, Weyman JC, Goldstone KE (1997) CT standard protocols are of limited value in assessing actual patient dose. Br J Radiol 70:1146–1151
Wong ETH, Yu SK, Lai M, Wong YC, Lau PC (2000) MAPD—an objective way to select mAs for paediatric brain CT. Br J Radiol 74:932–937
Karabulut N, Toru M, Gelebek V, Gulsun M, Ariyurek OM (2002) Comparison of low-dose and standard-dose helical CT in the evaluation of pulmonary nodules. Eur Radiol 12:2764–2769
Wilting JE, Zwartkruis A, van Leeuwen MS et al (2001) A rational approach to dose reduction in CT: individualized scan protocols. Eur Radiol 11:2627–2632
Verdun FR, Lepori D, Monnin P, Valley JF, Schnyder P, Gudinchet F (2004) Management of patient dose and image noise in routine pediatric CT abdominal examinations. Eur Radiol 14:835–8411
Kalra MK, Prasad S, Saini S et al (2002) Clinical comparison of standard-dose and 50% reduced-dose abdominal CT: effect on image quality. Am J Roentgenol 179:1101–1106
Cohnen M, Fischer H, Hamacher J et al (2000) CT of the head by use of reduced current and kilovoltage: relationship between image quality and dose reduction. Am J Neuroradiol 21:1654–1660
Chan CY, Wong YC, Chau LF, Yu SK, Lau PC (1999) Radiation dose reduction in paediatric cranial CT. Pediatr Radiol 29:770–775
Nickoloff E (2002) Current adult and pediatric CT doses. Pediatr Radiol 32:250–260
Takahashi M, Maguire WM, Ashtari M et al (1998) Low-dose spiral computed tomography of the thorax: comparison with the standard-dose technique. Invest Radiol 33:68–73
Marmolya G, Wiesen EJ, Yagan R, Haria CD, Shah AC (1991) Paranasal sinuses: low-dose CT. Radiology 181:689–691
Kamel RI, Hemandez JR, Martin EJ et al (1994) Radiation dose reduction in CT of pediatric pelvis. Radiology 190:683–687
Zeman RK, Fox SH, Silverman PM, Davros WJ, Carter LM, Griego D (1993) Helical (spiral) CT of the abdomen. Am J Roentgenol 160:719–725
Fearon T (2002) CT dose parameters and their limitations. Pediatr Radiol 32:246–249
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Gündoğdu, S., Mahmutyazıcıoğlu, K., Özdemir, H. et al. Assessment of image quality of a standard and three dose-reducing protocols in adult cranial CT. Eur Radiol 15, 1959–1968 (2005). https://doi.org/10.1007/s00330-004-2550-7
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00330-004-2550-7