Abstract
The purpose of this study was to evaluate the performance and complication rate of CT-guided percutaneous lung biopsy of pulmonary lesions using a coaxial automated biopsy device and to determine factors influencing the false negative rate for the diagnosis of malignancy. A prospective study of 605 consecutive biopsies performed in 595 patients was undertaken. The performances for the diagnosis of malignancy, for the specific diagnosis of benignity and the complication rate were calculated. Patients’ characteristics and lesion and procedure variables were included in a logistic regression model and analyzed as potential predictive variables for occurrence of a false-negative diagnosis of malignancy. The sensitivity, specificity, positive predictive value and negative predictive value for a diagnosis of malignancy were 92.2, 99.1, 99.8 and 73.3%, respectively. A specific diagnosis of benignity was obtained in 43 cases (40%) biopsies. The pneumothorax rate was 17.4% (n=105) with 3 (0.5%) requiring drainage. At multivariate analysis, the sole variable significantly associated with a higher rate of false negative diagnosis of malignancy was lesion size equal to or smaller than 10 mm in diameter. Using a coaxial automated device, CT-guided percutaneous biopsy of pulmonary lesions of size equal to or less than 10 mm in diameter provides a high diagnostic yield with an acceptable complication rate.
Similar content being viewed by others
References
Westcott JL (1980) Direct percutaneous needle aspiration of localized pulmonary lesions: result in 422 patients. Radiology 137:31–35
Miller DA, Carrasco CH, Katz RL, Cramer FM, Wallace S, Charnsangavej C (1986) Fine needle aspiration biopsy: the role of immediate cytologic assessment. Am J Roentgenol 147:155–158
Austin JH, Cohen MB (1993) Value of having a cytopathologist present during percutaneous fine-needle aspiration biopsy of lung: report of 55 cancer patients and metaanalysis of the literature. Am J Roentgenol 160:175–177
Padhani AR, Scott WW Jr, Cheema M, Kearney D, Erozan YS (1997) The value of immediate cytologic evaluation for needle aspiration lung biopsy. Invest Radiol 32:453–458
Lucidarme O, Howarth N, Finet JF, Grenier PA (1998) Intrapulmonary lesions: percutaneous automated biopsy with a detachable, 18-gauge, coaxial cutting needle. Radiology 207:759–765
Moulton JS, Moore PT (1993) Coaxial percutaneous biopsy technique with automated biopsy devices: value in improving accuracy and negative predictive value. Radiology 186:515–522
Arakawa H, Nakajima Y, Kurihara Y, Niimi H, Ishikawa T (1996) CT-guided transthoracic needle biopsy: a comparison between automated biopsy gun and fine needle aspiration. Clin Radiol 51:503–506
Klein JS, Salomon G, Stewart EA (1996) Transthoracic needle biopsy with a coaxially placed 20-gauge automated cutting needle: results in 122 patients. Radiology 198:715–720
Laurent F, Latrabe V, Vergier B, Montaudon M, Vernejoux JM, Dubrez J (2000) CT-guided transthoracic needle biopsy of pulmonary nodules smaller than 20 mm: results with an automated 20-gauge coaxial cutting needle. Clin Radiol 55:281–287
Hosmer DWLS (1989) Applied logistic regression. Wiley, New York
Berquist TH, Bailey PB, Cortese DA, Miller WE (1980) Transthoracic needle biopsy: accuracy and complications in relation to location and type of lesion. Mayo Clin Proc 55:475–481
Westcott JL, Rao N, Colley DP (1997) Transthoracic needle biopsy of small pulmonary nodules. Radiology 202:97–103
Bocking A, Klose KC, Kyll HJ, Hauptmann S (1995) Cytologic versus histologic evaluation of needle biopsy of the lung, hilum and mediastinum. Sensitivity, specificity and typing accuracy. Acta Cytol 39:463–471
Oikonomou A, Matzinger FR, Seely JM, Dennie CJ, Macleod PJ (2003) Ultrathin needle (25 G) aspiration lung biopsy: diagnostic accuracy and complication rates. Eur Radiol 13:20
Hahn PF, Eisenberg PJ, Pitman MB, Gazelle GS, Mueller PR (1995) Cytopathologic touch preparations (imprints) from core needle biopsies: accuracy compared with that of fine-needle aspirates. Am J Roentgenol 165:1277–1279
Yamagami T, Shigeharu L, Takeharu K, Tanaka O, Nishimura M (2003) Combining fine-needle aspiration and core biopsy under CT fluoroscopy guidance: a better way to treat patients with lung nodules. Am J Roentgenol 180:811–815
Tsukada H, Satou T, Iwashima A, Souma T (2000) Diagnostic accuracy of CT-guided automated needle biopsy of lung nodules. Am J Roentgenol 175:239–243
Wallace MJ, Krishnamurthy S, Broemeling LD, Gupta S, Ahrar K, Morello FA Jr et al (2002) CT-guided percutaneous fine-needle aspiration biopsy of small (≤1-cm) pulmonary lesions. Radiology 225:823–828
Boiselle PM, Shepard JA, Mark EJ, Szyfelbein WM, Fan CM, Slanetz PJ et al (1997) Routine addition of an automated biopsy device to fine-needle aspiration of the lung: a prospective assessment. Am J Roentgenol 169:661–666
McLoud TC (1998) Should cutting needles replace needle aspiration of lung lesions? Radiology 207:569–570
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Montaudon, M., Latrabe, V., Pariente, A. et al. Factors influencing accuracy of CT-guided percutaneous biopsies of pulmonary lesions. Eur Radiol 14, 1234–1240 (2004). https://doi.org/10.1007/s00330-004-2250-3
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00330-004-2250-3