Abstract
The aim of this study was to investigate the accuracy of multidetector-row cardiac CT (MDCT), calcium scoring (Ca-Sc), and MDCT coronary angiography (MD CTA) in the assessment of coronary atherosclerosis. Thirty-eight patients underwent invasive coronary angiography (CA) and MDCT (collimation 4×1 mm, pitch 1.5 mm, TI 500 ms, 120 kV, 300 mAs, and retrospective ECG-gating). Calcium scoring was calculated for the total coronary artery territory and for RCA, LCA, and LCX separately. The MD CTA served to assess the degree and the localization of stenoses. All findings were compared to invasive coronary angiography. Approximately 68.4% (390 of 570) of all coronary segments could be visualized by MDCT. Correlation coefficient for MD CTA and CA amounted to r=0.58, showing distinct differences for the individual segments. Proximal segments generally showed better correlation (range 0.81–0.77) than medial segments (range 0.91–0.20), distal segments (range 0.55–0.04), or side branches (range 0.76–0.00). Patients with hemodynamically relevant (>75%) stenoses were detected by MD CTA with 72.2% sensitivity (13 of 18) and 100% specificity (20 of 20). For Ca-Sc sensitivity ranged between 94.7% (17 of 18) and 66.7% (12 of 18), specificity between 20% (4 of 20) and 80% (16 of 20) respectively, depending on the prevailing cutoff value. Combination of both methods led to 83.3% sensitivity (15 of 18) and 100% specificity (20 of 20), reaching no level of significance as compared with Ca-Sc (p=0.73) or MD CTA (p=0.23) alone. Calcium scoring as a single method showed highest sensitivity in the detection of coronary atherosclerosis but at the expense of low specificity. In patients with no or moderate calcifications, combination with MD CTA helped to distinctly increase specificity and NPV
Similar content being viewed by others
References
Wexler L, Brundage B, Crouse J, Detrano R, Fuster V, Maddahi J et al. (1996) Coronary artery calcification: pathophysiology, epidemiology, imaging methods, and clinical implications: a statement for health professionals from the American Heart Association. Circulation 94:1175–1192
Becker CR, Schoepf UJ, Reiser MF (2001) Methods for quantification of coronary artery calcifications with electron-beam and conventional CT and pushing the spiral CT envelope: new cardiac applications. Int J Cardiovasc Imaging 17:203–211
Becker CR, Knez A, Leber A, Treede H, Ohnesorge B, Schoepf UJ et al. (2002) Detection of coronary artery stenoses with multislice helical CT angiography. J Comput Assist Tomogr 26:750–755
Fischbach R, Heindel W (2000) Detection and quantification of coronary calcification: an update. Fortschr Rontgenstr 172:407–414
Hong C, Becker CR, Schoepf UJ, Ohnesorge B, Bruening R, Reiser M (2002) Coronary artery calcium: absolute quantification in non-enhanced and contrast-enhanced multi-detector row CT studies. Radiology 223:474–480
Kopp AF, Ohnesorge B, Becker C, Schroder S, Heuschmid M, Kuttner A et al. (2002) Reproducibility and accuracy of coronary calcium measurements with multi-detector row versus electron-beam CT. Radiology 225:113–119
Ohnesorge B, Flohr T, Fischbach R, Kopp AF, Knez A, Schroder S et al. (2002) Reproducibility of coronary calcium quantification in repeat examinations with retrospectively ECG-gated multisection spiral CT. Eur Radiol 12:1532–1540
Stanford W, Thompson BH (1999) Imaging of coronary artery calcification: its importance in assessing atherosclerotic disease. Radiol Clin North Am 37:257–272
American College of Cardiology/American Heart Association (2000) Expert consensus document on electron-beam computed tomography for the diagnosis and prognosis of coronary artery diseaese. Circulation 102:126–140
Bormann JL, Stanford W, Stenberg RG (1992) Ultrafast tomographic detection of coronary artery calcification as an indicator of stenosis. Am J Card Imaging 6:191–196
Falk E (1983) Plaque rupture with severe pre-existing stenosis precipitating coronary thrombosis: characteristics of coronary atherosclerotic plaques underlying fatal occlusive thrombi. Br Heart J 50:127–134
Schmermund A, Baumgart D, Gorge G, Seibel R, Gronemeyer D, Ge J et al. (1997) Coronary artery calcium in acute coronary syndromes: a comparative study of electron-beam computed tomography, coronary angiography, and intracoronary ultrasound in survivors of acute myocardial infarction and unstable angina. Circulation 96:1461–1469
Flohr T, Ohnesorge B (2001) Heart-rate-adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart. J Comput Assist Tomogr 25:907–923
Fuchs T, Krause J, Schaller S, Flohr T, Kalender WA (2000) Spiral interpolation algorithms for multislice spiral CT. Part II: Measurement and evaluation of slice sensitivity profiles and noise at a clinical multislice system. IEEE Trans Med Imaging 19:835–847
Ohnesorge B, Flohr T, Becker C, Kopp AF, Schoepf UJ, Baum U et al. (2000) Cardiac imaging by means of electrocardiographically gated multisection spiral CT: initial experience. Radiology 217:564–571
Kopp AF, Schroeder S, Baumbach A, Kuettner A, Georg C, Ohnesorge B et al. (2001) Non-invasive characterisation of coronary lesion morphology and composition by multislice CT: first results in comparison with intracoronary ultrasound. Eur Radiol 11:1607–1611
Becker CR, Knez A, Leber A, Hong C, Treede H, Wildhirt S et al. (2000) Initial experiences with multi-slice detector spiral CT in diagnosis of arteriosclerosis of coronary vessels. Radiologe 40:118–122
Vogl TJ, Abolmaali ND, Diebold T, Engelmann K, Ay M, Dogan S et al. (2002) Techniques for the detection of coronary atherosclerosis: multi-detector row CT coronary angiography. Radiology 223:212–220
Diamond GA, Forrester JS (1979) Analysis of probability as an aid in the clinical diagnosis of coronary artery disease. N Engl J Med 300:1350–1358
Ohnesorge B, Flohr T, Becker C, Knez A, Kopp AF, Fukuda K et al. (2000) Cardiac imaging with rapid, retrospective ECG-synchronized multilevel spiral CT. Radiologe 40:111–117
Herzog C, Abolmaali N, Balzer JO, Baunach S, Ackermann H, Dogan S et al. (2002) Heart-rate-adapted image reconstruction in multidetector-row cardiac CT: influence of physiological and technical prerequisite on image quality. Eur Radiol 12:2670–2678
American College of Cardiology/American Heart Association (1991) Guidelines for cardiac catheterization and cardiac catheterization laboratories. American College of Cardiology/American Heart Association Ad Hoc Task Force on Cardiac Catheterization. J Am Coll Cardiol 18:1149–1182
Bowker A (1948) A test for symmetry in contingency tables. J Am Stat Assoc 43:572–574
Agatston AS, Janowitz WR, Hildner FJ, Zusmer NR, Viamonte M, Detrano R (1990) Quantification of coronary artery calcium using ultrafast computed tomography. J Am Coll Cardiol 15:827–832
Rumberger JA, Brundage BH, Rader DJ, Kondos G (1999) Electron beam computed tomographic coronary calcium scanning: a review and guidelines for use in asymptomatic persons. Mayo Clin Proc 74:243–252
Becker CR, Knez A, Ohnesorge B, Schoepf UJ, Flohr T, Bruening R et al. (2000) Visualization and quantification of coronary calcifications with electron beam and spiral computed tomography. Eur Radiol 10:629–635
Becker CR, Kleffel T, Crispin A, Knez A, Young J, Schoepf UJ et al. (2001) Coronary artery calcium measurement: agreement of multirow detector and electron beam CT. Am J Roentgenol 176:1295–1298
Achenbach S, Daniel WG, Moshage W (2001) Recommendations for standardization of EBT and MSCT scanning. Herz 26:273–277
Becker CR, Ohnesorge BM, Schoepf UJ, Reiser MF (2000) Current development of cardiac imaging with multidetector-row CT. Eur J Radiol 36:97–103
Nieman K, Oudkerk M, Rensing BJ, van Ooijen P, Munne A, van Geuns RJ et al. (2001) Coronary angiography with multi-slice computed tomography. Lancet 357:599–603
Kopp AF, Schroeder S, Kuettner A (2000) Multidetector-row CT for non-invasive coronary angiography: results in 102 patients. Radiology 217:487
Fischbach R, Wichter T, Juergens KU (2001) Multidetector-row spiral CT of the coronary arteries: comparison with coronary angiography. Fortschr Roentgenstr 173:26
Jakobs TF, Becker CR, Wintersperger BJ, Herzog P, Ohnesorge B, Flohr T et al. (2002) CT angiography of the coronary arteries with a 16-row spiral tomograph: effect of spatial resolution on image quality. Radiologe 42:733–738
Kopp AF, Heuschmid M, Claussen CD (2002) Multidetector helical CT of the liver for tumor detection and characterization. Eur Radiol 12:745–752
Wintersperger BJ, Herzog P, Jakobs T, Reiser MF, Becker CR (2002) Initial experience with the clinical use of a 16-detector-row CT system. Crit Rev Comput Tomogr 43:283–316
Ulzheimer S, Kalender WA (2003) Assessment of calcium scoring performance in cardiac computed tomography. Eur Radiol 13:484–497
Author information
Authors and Affiliations
Corresponding author
Additional information
M. Britten and C. Herzog contributed equally to this study
Rights and permissions
About this article
Cite this article
Herzog, C., Britten, M., Balzer, J.O. et al. Multidetector-row cardiac CT: diagnostic value of calcium scoring and CT coronary angiography in patients with symptomatic, but atypical, chest pain. Eur Radiol 14, 169–177 (2004). https://doi.org/10.1007/s00330-003-2197-9
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00330-003-2197-9