Abstract.
The objective of this study was to compare contrast-enhanced magnetic resonance angiography (CE MRA) and multislice computed tomographic angiography (MS CTA) in the follow-up of thoracic stent-graft placement. The CE MRA and MS CTA were performed following nitinol stent-graft treatment due to thoracic aneurysm (n=4), intramural bleeding (n=2) and type-B aortic dissection (n=5). Corresponding evaluation of arterial-phase imaging characteristics focused on the stent-graft morphology and leakage assessment. Stent-graft and aneurysm extensions were comparable between both techniques. Complete exclusion (aneurysm, n=4; dissection, n=2) was assessed with high confidence with CE MRA and MS CTA. Incomplete exclusion (intramural bleeding, n=2; dissection, n=3) was assigned to lower confidence scores on CE MRA compared with MS CTA. On CE MRA the stent-graft lumen demonstrated an inhomogeneous signal, the stent struts could not be assessed. The CE MRA can be used as alternative non-invasive imaging for follow-up of nitinol stent grafts. Arterial-phase leak assessment can be less evident in CE MRA compared with MS CTA studies; therefore, the use of late-phase imaging seems to be necessary. The diagnostic gap of stent-graft fracture evaluation using MRA may be filled with plain radiographs.
Similar content being viewed by others
References
Nienaber CA, Fattori R, Lund G et al. (1999) Nonsurgical reconstruction of thoracic aortic dissection by stent-graft placement. N Engl J Med 340:1539–1545
Armerding MD, Rubin GD, Beaulieu CF et al. (2000) Aortic aneurysmal disease: assessment of stent-graft treatment: CT versus conventional angiography. Radiology 215:138–146
Kato N, Dake MD, Miller DC et al. (1997) Traumatic thoracic aortic aneurysm: treatment with endovascular stent-grafts. Radiology 205:657–662
Grabenwöger M, Hutschala D, Ehrlich MP et al. (2000) Thoracic aortic aneurysms: treatment with endovascular self-expandable stent grafts. Ann Thorac Surg 69:441–445
Thurnher SA, Grabenwoger M (2002) Endovascular treatment of thoracic aneurysms: a review. Eur Radiol 12:1370–1387
Sakai T, Dake MD, Semba CP et al. (1999) Descending thoracic aortic aneuryms: thoracic CT findings after endovascular stent-graft placement. Radiology 212:169–174
Mita T, Arita T, Matsunaga N et al. (2000) Complications of endovascular repair for thoracic and abdominal aortic aneurysm: an imaging spectrum. Radiographics 20:1263–1278
Maspes F, Gandini R, Pocek M et al. (1999) Breath-hold gadolinium enhanced three-dimensional MR angiography: personal experience in the thoracic-abdominal area. Radiol Med 98:275–282
Hilfiker PR, Quick HH, Pfammatter T et al. (1999) Three-dimensional MR angiography of a nitinol-based abdominal aortic stent graft: assessment of heating and imaging characteristics. Eur Radiol 9:1775–1780
Hilfiker PR, Quick HH, Schmidt M et al. (1999) In vitro image characteristics of an abdominal aortic stent graft: CTA versus 3D MRA. MAGMA 8:27–32
Engellau L, Larrson EM, Albrechtsson U et al. (1998) Magnetic resonance imaging and MR angiography of endoluminal treated abdominal aortic aneuryms. Eur J Vasc Endovasc Surg 15:212–219
Lenhart M, Volk M, Manke C et al. (2000) Stent appearance at contrast-enhanced MR angiography: in vivo examination with 14 stents. Radiology 217:173–178
Maintz D, Kugel H, Schellhammer F et al. (2001) In vitro evaluation of intravascular stent artifacts in three-dimensional MR angiography. Invest Radiol 36:218–224
Hansmann HJ, Kampschulte A, Schumacher H et al. (2001) Rational radiologic after-care of endoluminal aortic bypass. Radiologe 41:674–680
Balm R, Kaatee R, Blankensteijn JD et al. (1996) CT-angiography of abdominal aortic aneurysms after transfemoral endovascular aneurysm management. Eur J Vasc Endovasc Surg 12:182–188
Chavan A, Cohnert TU, Heine J et al. (2000) Endoluminal grafting of abdominal aortic aneurysms: experience with the Talent endoluminal stent graft. Eur Radiol 10:636–641
Engellau L, Olsrud J, Brockstedt S et al. (2000) MR evaluation ex vivo and in vivo of a covered stent-graft for abdominal aortic aneurysms: ferromagnetism, heating, artifacts and velocity mapping. J Magn Reson Imaging 12:112–121
Golzarian J, Dussaussois L, Abada HT et al. (1998) Helical CT of aorta after endoluminal stent-graft therapy: value of biphasic acquisition. Am J Roentgenol 171:329–331
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Weigel, S., Tombach, B., Maintz, D. et al. Thoracic aortic stent graft: comparison of contrast-enhanced MR angiography and CT angiography in the follow-up: initial results. Eur Radiol 13, 1628–1634 (2003). https://doi.org/10.1007/s00330-003-1832-9