Dacron graft aneurysm treated by endovascular stent-graft

  • Case Reports
  • Published:
CardioVascular and Interventional Radiology Aims and scope Submit manuscript

Abstract

A 72-year old man who underwent aorto-bifemoral bypass with insertion of a Dacron graft 18 years previously presented with an aneurysm in the left limb of his graft. Angiography also demonstrated a bilateral occlusion of the popliteal arteries. Computed tomography (CT) angiography was performed and showed a localized dilation of 3 cm in the left limb of the graft, which had a diameter of 14 mm throughout. In view of the technical difficulties of a surgical procedure, an endovascular stent was considered. Through a left femoral arteriotomy. a stent graft was inserted and deployed in the left limb of the graft. This resulted in total exclusion of the Dacron graft aneurysm. To the best of our knowledge, this is the first report of such a procedure.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. DeBakcv ME, Jordan GL, Abbott JP (1964) The fate of Dacron vascular grafts. Arch Surg 89:757–782

    Google Scholar 

  2. Wilson SE, Krug R, Mueller G, Wilson I (1997) Late disruption of Dacron aortic grafts. Ann Vase Surg 11:383–386

    Article  CAS  Google Scholar 

  3. Nunn DB, Pourdeyhimi B (1997) Intrinsic Dacron graft failure 19 years post-implantation. Cardiovasc Surg 5:333–338

    Article  PubMed  CAS  Google Scholar 

  4. Beveridge CJ, Pleass HCC, Chamberlain J, Wyatt MG, Rose JDG (1998) Aorto-iliac aneurysm with arteriocaval fistula treated by a bifurcated stent-graft. Cardiovasc Intervent Radiol 21:244–246

    Article  PubMed  CAS  Google Scholar 

  5. Blum U, Voshage G, Lammer J, Beyerdorf F, Tollner D, Kretschmer G, Spillner G, Polterauer P, Nagel G, Holzenbein T (1997) Endoluminal stent-grafts for infrarenal abdominal aortic aneurysms. N Engl J Med 336:13–20

    Article  PubMed  CAS  Google Scholar 

  6. Murphy KD, Richter GM, Henry M, Encarnacion CE, Le Van A, Palmaz JC (1996) Aortoiliac aneurysms: Management with endovascular stem-graft placement. Radiology 198:473–480

    PubMed  CAS  Google Scholar 

  7. Dake MD, Miller DC, Semba CP, Mitchell RS, Walker RS, Liddell RP (1994) Transluminal placement of endovascular stent-grafts for the treatment of descending thoracic aortic aneurysms. N Engl J Med 331:1729–1734

    Article  PubMed  CAS  Google Scholar 

  8. Creech O, DeBakey M (1966) Endoaneurysmorrhaphy and treatment of aortic aneurysm. Ann Surg 164:935–946

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Amos Ofer.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Ofer, A., Nitecki, S., Hoffman, A. et al. Dacron graft aneurysm treated by endovascular stent-graft. Cardiovasc Intervent Radiol 24, 60–64 (2001). https://doi.org/10.1007/s002700001722

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s002700001722

Key words

Navigation