Abstract
Purpose
To describe a sequential deployment technique of the Zenith® t-Branch™ device for branched endovascular aortic aneurysm repair that might reduce potential rotation and increases optimal positioning of the device.
Technique
After obtaining bilateral groin and right brachial access, the device is advanced over a through-and-through brachio-femoral guidewire and positioned based on prior measurements and landmarks. The t-Branch device is deployed one branch at a time and each visceral branch is sequentially catheterized from brachial access using live CT-fusion and intravascular ultrasound guidance. Full deployment prior to branch catheterization is avoided to maintain device stability, reduced spontaneous rotation, wider working room and freedom in positioning of the device while target artery catheterization is secured.
Conclusion
Sequential catheterization amid progressive deployment of the Zenith® t-Branch™ device is an effective method of deployment of the device that ensures optimal positioning and secured catheterization of the target vessels.
References
Chuter TA, Gordon RL, Reilly LM, et al. An endovascular system for thoracoabdominal aortic aneurysm repair. J Endovasc Ther. 2001;8:25–33.
Anderson JL, Adam DJ, Berce M, Hartley DE. Repair of thoracoabdominal aortic aneurysms with fenestrated and branched endovascular stent grafts. J Vasc Surg. 2005;42:600–7.
Sweet MP, Hiramoto JS, Park KH, et al. A standardized multi-branched thoracoabdominal stentgraft for endovascular aneurysm repair. J Endovasc Ther. 2009;16:359–64.
Silingardi R, Gennai S, Leone N, et al. Standard “off-the-shelf” multibranched thoracoabdominal endograft in urgent and elective patients with single and staged procedures in a multicenter experience. J Vasc Surg. 2018;67:1005–166.
Bosiers MJ, Bisdas T, Donas KP, et al. Early experience with the first commercially available off-the-shelf multibranched endograft (t-Branch) in the treatment of thoracoabdominal aortic aneurysms. J Endovasc Ther. 2013;20:719–25.
Bisdas T, Donas KP, Bosiers MJ, et al. Custom-made versus off-the-shelf multibranched endografts for endovascular repair of thoracoabdominal aortic aneurysms. J Vasc Surg. 2014;60:1186–95.
Fernandez CC, Sobel JD, Gasper WJ, et al. Standard off-the-shelf versus custom-made multibranched thoracoabdominal aortic stent grafts. J Vasc Surg. 2016;63:1208–15.
Gallitto E, Gargiulo M, Freyrie A, et al. Off-the-shelf multibranched endograft for urgent endovascular repair of thoracoabdominal aortic aneurysms. J Vasc Surg. 2017;66:696–704.e5.
Spanos K, Kölbel T, Theodorakopoulou M, et al. Early outcomes of the t-Branch off-the-shelf multibranched stent-graft in urgent thoracoabdominal aortic aneurysm repair. J Endovasc Ther. 2018;25(1):31–9.
Timaran CH, Stanley GA, Baig MS, et al. The sequential catheterization amid progressive endograft deployment technique for fenestrated endovascular aortic aneurysm repair. J Vasc Surg. 2017;66(1):311–5.
Coselli JS, LeMaire SA, Preventza O, et al. Outcomes of 3309 thoracoabdominal aortic aneurysm repairs. J Thorac Cardiovasc Surg. 2016;151:1323–38.
Conrad MF, Crawford RS, Davison JK, Cambria RP. Thoracoabdominal aneurysm repair: a 20-year perspective. Ann Thorac Surg. 2007;83:S856–61.
Murana G, Castrovinci S, Kloppenburg G, et al. Open thoracoabdominal aortic aneurysm repair in the modern era: results from a 20-year single centre experience. Eur J Cardiothorac Surg. 2016;49:1374–81.
Knowles M, Nation DA, Timaran DE, et al. Upper extremity access for fenestrated endovascular aortic aneurysm repair is not associated with increased morbidity. J Vasc Surg. 2015;61(1):80–7.
Spanos K, Theodorakopoulou M, Debus ES, et al. Accurate orientation of the t-Branch off-the-shelf multibranched endograft after deployment in urgent cases. J Endovasc Ther. 2018;25(4):442–9.
Ferreira M, Ferreira D, Cunha R, Bicalho G, Rodrigues E. Advanced technical considerations for implanting the t-Branch off-the-shelf multibranched stent-graft to treat thoracoabdominal aneurysms. J Endovasc Ther. 2018;25(4):450–5.
Plotkin A, Ding L, Han SM, Oderich GS, et al. Association of upper extremity and neck access with stroke in endovascular aortic repair. J Vasc Surg. 2020;S0741–5214(20):30289–95.
Acknowledgements
The authors thank Soheila Talaeizadeh for her dedication in production of the medical illustrations of this article.
Funding
This study was not supported by any funding.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The author(s) declare the following potential conflicts of interest with respect to the research, authorship, and/or publication of this article: Carlos H. Timaran has received consulting fees and research support from Cook Medical, Gore Medical, and Philips Medical Systems.
Ethical Approval
All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.
Informed Consent
The patients enrolled in this physician-sponsored IDE study, signed an institutional review board (IRB) approved informed consent form to participate in research (ClinicalTrials.gov # NCT02266719). For this type of technique report, a separate consent for publication is not required.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Malekpour, F., Scott, C.K., Kirkwood, M.L. et al. Sequential Catheterization and Progressive Deployment of the Zenith® t-Branch™ Device for Branched Endovascular Aortic Aneurysm Repair. Cardiovasc Intervent Radiol 44, 156–160 (2021). https://doi.org/10.1007/s00270-020-02654-8
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00270-020-02654-8