Purpose

To evaluate the volumetric changes in abdominal aortic aneurysms (AAA) after endovascular AAA repair (EVAR) in 24 months of follow-up.

Methods

We evaluated the volume modifications in 63 consecutive patients after EVAR. All patients underwent strict duplex ultrasound and computed tomography angiography (CTA) follow-up; when complications were suspected, digital subtraction angiography was also performed. CTA datasets at 1, 6, 12, and 24 months were post-processed through semiautomatic segmentation, to isolate the aneurysmal sac and calculate its volume. Maximum transverse diameters (Dmax) were also obtained in the true axial plane, Presence and type of endoleak (EL) were recorded. A statistical analysis was performed to assess the degree of volume change, correlation with diameter modifications, and significance of the volume increase with respect to ELs.

Results

Mean reconstruction time was 7 min. Mean volume reduction rates were 6.5%, 8%, and 9.6% at 6, 12, and 24 months follow-up, respectively. Mean Dmax reduction rates were 4.2%, 6.7%, and 12%; correlation with volumes was poor (r = 0.73–0.81). ELs were found in 19 patients and were more frequent (p = 0.04) in patients with higher preprocedural Dmax, The accuracies of volume changes in predicting ELs ranged between 74.6% and 84.1% and were higher than those of Dmax modifications. The strongest independent predictor of EL was a volume change at 6 months ≤0.3% (p = 0.005), although 6 of 19 (32%) patients with EL showed no significant AAA enlargement, whereas in 6 of 44 (14%) patients without EL the aneurysm enlarged.

Conclusion

The lack of volume decrease in the aneurysm of at least 0.3% at 6 months follow-up indicates the need for closer surveillance, and has a higher predictive accuracy for an endoleak than Dmax.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Figure 1
Figure 2
Figure 3

Similar content being viewed by others

References

  1. JC Parodi JC Palmaz HD Barone (1991) ArticleTitleTransfemoral intraluminal graft implantation for abdominal aortic aneurysms Ann Vasc Surg 5 491–499 Occurrence Handle1:STN:280:DyaK387is1Cltw%3D%3D Occurrence Handle10.1007/BF02015271 Occurrence Handle1837729

    Article  CAS  PubMed  Google Scholar 

  2. LH Walschot RJ Laheij AL Verbeek (2002) ArticleTitleOutcome after endovascular abdominal aortic aneurysm repair: A meta-analysis J Endovasc Ther 9 82–89 Occurrence Handle10.1177/152660280200900114 Occurrence Handle11958330

    Article  PubMed  Google Scholar 

  3. CK Zarins RA White FL Moll et al. (2001) ArticleTitleThe AneuRx stent graft: Four-year results and worldwide experience 2000 J Vasc Surg 33 IssueID2 Suppl S135–S145 Occurrence Handle1:STN:280:DC%2BD3M7lslynuw%3D%3D Occurrence Handle10.1067/mva.2001.111676 Occurrence Handle11174825

    Article  CAS  PubMed  Google Scholar 

  4. ML Marin LH Hollier SH Ellozy et al. (2003) ArticleTitleEndovascular stent graft repair of abdominal and thoracic aortic aneurysms: A ten-year experience with 817 patients Ann Surg 238 586–593 Occurrence Handle14530730 Occurrence Handle1360117

    PubMed  PubMed Central  Google Scholar 

  5. TAM Chuter K Ivancev M Malina et al. (1996) ArticleTitleAneurysm pressure following endovascular exclusion Eur J Vasc Endovasc Surg 13 85–87 Occurrence Handle10.1016/S1078-5884(97)80056-1

    Article  Google Scholar 

  6. S Elkouri P Gloviczki MA McKusick et al. (2004) ArticleTitlePerioperative complications and early outcome after endovascular and open surgical repair of abdominal aortic aneurysms J Vasc Surg 39 497–505 Occurrence Handle10.1016/j.jvs.2003.10.018 Occurrence Handle14981437

    Article  PubMed  Google Scholar 

  7. WA Lee JW Carter G Upchurch et al. (2004) ArticleTitlePerioperative outcomes after open and endovascular repair of intact abdominal aortic aneurysms in the United States during 2001 J Vasc Surg 39 491–496 Occurrence Handle10.1016/j.jvs.2003.12.001 Occurrence Handle14981436

    Article  PubMed  Google Scholar 

  8. MA Corriere ID Feurer SY Becker et al. (2004) ArticleTitleEndoleak following endovascular abdominal aortic aneurysm repair: Implications for duration of screening Ann Surg 239 800–807 Occurrence Handle10.1097/01.sla.0000128300.60156.ab Occurrence Handle15166959 Occurrence Handle1356288

    Article  PubMed  PubMed Central  Google Scholar 

  9. GA Fransen SR Vallabhaneni SuffixSr CJ Marrewijk Particlevan et al. (2003) ArticleTitleRupture of infta-renal aortic aneurysm after endovascular repair: A series from EUROSTAR registry Eur J Vasc Endovasc Surg 26 487–493 Occurrence Handle1:STN:280:DC%2BD3svntVWntg%3D%3D Occurrence Handle10.1016/S1078-5884(03)00350-2 Occurrence Handle14532875

    Article  CAS  PubMed  Google Scholar 

  10. J Golzarian L Dussaussois HT Abada et al. (1998) ArticleTitleHelical CT of aorta after endoluminal stent-graft therapy: Value of biphasic acquisition AJR Am J Roentgenol 171 329–331 Occurrence Handle1:STN:280:DyaK1czlslyiug%3D%3D Occurrence Handle10.2214/ajr.171.2.9694445 Occurrence Handle9694445

    Article  CAS  PubMed  Google Scholar 

  11. S Thurnher M Cejna (2002) ArticleTitleImaging of aortic stent-grafts and endoleaks Radiol Clin North Am 40 799–833 Occurrence Handle10.1016/S0033-8389(02)00024-6 Occurrence Handle12171186

    Article  PubMed  Google Scholar 

  12. AM Rozenblit M Patlas AT Rosenbaum et al. (2003) ArticleTitleDetection of endoleaks after endovascular repair of abdominal aortic aneurysm: Value of unenhanced and delayed Helical CT acquisitions Radiology 227 426–433 Occurrence Handle10.1148/radiol.2272020555 Occurrence Handle12676973

    Article  PubMed  Google Scholar 

  13. KG Raman N Missig-Carroll T Richardson et al. (2003) ArticleTitleColor-flow duplex ultrasound scan versus computed tomographic scan in the surveillance of endovascular aneurysm repair J Vasc Surg 2003 38 645–651

    Google Scholar 

  14. GL Gilling-Smith J Martin S Sudhindran et al. (2000) ArticleTitleFreedom from endoleak after endovascular aneurysm repair does not equal treatment success Eur J Vasc Endovasc Surg 19 421–425 Occurrence Handle1:STN:280:DC%2BD3c3msVWisg%3D%3D Occurrence Handle10.1053/ejvs.1999.1029 Occurrence Handle10801377

    Article  CAS  PubMed  Google Scholar 

  15. M Mehta FJ Veith T Ohki et al. (2003) ArticleTitleSignificance of endotension, endoleak, and aneurysm pulsatility after endovascular repair J Vasc Surg 37 842–846 Occurrence Handle10.1067/mva.2003.183 Occurrence Handle12663987

    Article  PubMed  Google Scholar 

  16. MC Farner JP Carpenter RA Baum et al. (2003) ArticleTitleEarly changes in abdominal aortic aneurysm diameter after endovascular repair J Vasc Interv Radiol 14 205–210 Occurrence Handle10.1097/01.RVI.0000058322.82956.ad Occurrence Handle12582188

    Article  PubMed  Google Scholar 

  17. YG Wolf BB Hill GD Rubin et al. (2000) ArticleTitleRate of change in abdominal aortic aneurysm diameter after endovascular repair J Vasc Surg 32 108–115 Occurrence Handle1:STN:280:DC%2BD3czjs1Oktg%3D%3D Occurrence Handle10.1067/mva.2000.107754 Occurrence Handle10876211

    Article  CAS  PubMed  Google Scholar 

  18. R Balm R Kaatee JD Blankensteijn et al. (1996) ArticleTitleCT-angiography of abdominal aortic aneurysms after transfemoral endovascular management Eur J Vasc Endovasc Surg 12 182–188 Occurrence Handle1:STN:280:DyaK28zksl2gsw%3D%3D Occurrence Handle10.1016/S1078-5884(96)80104-3 Occurrence Handle8760980

    Article  CAS  PubMed  Google Scholar 

  19. MP Armon SW Yusuf SC Whitaker et al. (1998) ArticleTitleThrombus distribution and changes in aneurysm size following endovascular aortic aneurysm repair Eur J Vasc Endovasc Surg 16 472–476 Occurrence Handle1:STN:280:DyaK1M7htFymtA%3D%3D Occurrence Handle10.1016/S1078-5884(98)80236-0 Occurrence Handle9894485

    Article  CAS  PubMed  Google Scholar 

  20. JJ Wever JD Blankensteijn M WP Th Mali et al. (2000) ArticleTitleMaximal aneurysm diameter follow-up is inadequate after endovascular abdominal aortic aneurysm repair Eur J Vasc Endovasc Surg 20 177–182 Occurrence Handle1:STN:280:DC%2BD3cvjtlOhtQ%3D%3D Occurrence Handle10.1053/ejvs.1999.1051 Occurrence Handle10942691

    Article  CAS  PubMed  Google Scholar 

  21. BV Czermak G Fraedrich MF Schocke et al. (2001) ArticleTitleSerial CT volume measurements after endovascular aortic aneurysm repair J Endovasc Ther 8 380–389 Occurrence Handle1:STN:280:DC%2BD3Mrgt1Kruw%3D%3D Occurrence Handle10.1177/152660280100800407 Occurrence Handle11552730

    Article  CAS  PubMed  Google Scholar 

  22. B Kritpracha HG Beebe AJ Comerota (2004) ArticleTitleAortic diameter is an insensitive measurement of early aneurysm expansion after endografting J Endovasc Ther 11 184–190 Occurrence Handle10.1583/03-976.1 Occurrence Handle15056034

    Article  PubMed  Google Scholar 

  23. JT Lee IN Aziz JT Lee et al. (2003) ArticleTitleVolume regression of abdominal aortic aneurysms and its relation to successful endoluminal exclusion J Vasc Surg 38 1254–1263 Occurrence Handle10.1016/S0741-5214(03)00924-8 Occurrence Handle14681624

    Article  PubMed  Google Scholar 

  24. RA White CE Donayre I Walot et al. (2001) ArticleTitleComputed tomography assessment of abdominal aortic aneurysm morphology after endograft exclusion J Vasc Surg 33 S1–S10 Occurrence Handle1:STN:280:DC%2BD3M7lslynsw%3D%3D Occurrence Handle10.1067/mva.2001.111680 Occurrence Handle11174806

    Article  CAS  PubMed  Google Scholar 

  25. M Prinssen EL Verhoeven HJ Verhagen et al. (2003) ArticleTitleDecision-making in follow-up after endovascular aneurysm repair based on diameter and volume measurements: A blinded comparison Eur J Vasc Endovasc Surg 26 184–187 Occurrence Handle1:STN:280:DC%2BD3szotFGksQ%3D%3D Occurrence Handle10.1053/ejvs.2002.1892 Occurrence Handle12917836

    Article  CAS  PubMed  Google Scholar 

  26. YG Wolf M Tillich WA Lee et al. (2002) ArticleTitleChanges in aneurysm volume after endovascular repair of abdominal aortic aneurysm J Vasc Surg 36 305–309 Occurrence Handle10.1067/mva.2002.126085 Occurrence Handle12170211

    Article  PubMed  Google Scholar 

  27. JJ Wever JD Blankensteijn JC Rijn Particlevan et al. (2000) ArticleTitleInter- and intraobserver variability of CT measurements obtained after endovascular repair of abdominal aortic aneurysms AJR Am J Roentgenol 175 1279–1282 Occurrence Handle1:STN:280:DC%2BD3M%2FisVOqtA%3D%3D Occurrence Handle10.2214/ajr.175.5.1751279 Occurrence Handle11044022

    Article  CAS  PubMed  Google Scholar 

  28. FJ Veith RA Baum T Ohki et al. (2002) ArticleTitleNature and significance of endoleaks and endotension: Summary of opinions expressed at an international conference J Vasc Surg 35 1029–1035 Occurrence Handle10.1067/mva.2002.123095 Occurrence Handle12021724

    Article  PubMed  Google Scholar 

  29. ES Sampram MT Karafa EJ Mascha et al. (2003) ArticleTitleNature, frequency, and predictors of secondary procedures after endovascular repair of abdominal aortic aneurysm J Vasc Surg 37 930–937 Occurrence Handle10.1067/mva.2003.281 Occurrence Handle12756335

    Article  PubMed  Google Scholar 

  30. Prinssen M, Wixon CL, Buskens E, et al (2004) Surveillance after endovascular aneurysm repair: Diagnostics, complications, and associated costs. Ann Vasc Surg 18:421–427

    Article  PubMed  Google Scholar 

  31. JG Pollock SJ Travis SC Whitaker et al. (2002) ArticleTitleEndovascular AAA repair: Classification of aneurysm sac volumetric change using spiral computed tomographic angiography J Endovasc Ther 9 185–193 Occurrence Handle10.1177/152660280200900208 Occurrence Handle12010098

    Article  PubMed  Google Scholar 

  32. CB Rockman PJ Lamparello MA Adelman et al. (2002) ArticleTitleAneurysm morphology as a predictor of endoleak following endovascular aortic aneurysm repair: do smaller aneurysm have better outcomes? Ann Vasc Surg 16 644–651 Occurrence Handle10.1007/s10016-001-0200-y Occurrence Handle12183772

    Article  PubMed  Google Scholar 

  33. R Singh-Ranger T McArthur MD Corte et al. (2000) ArticleTitleThe abdominal aortic aneurysm sac after endoluminal exclusion: A medium-term morphologic follow-up based on volumetric technology J Vasc Surg 31 490–500 Occurrence Handle1:STN:280:DC%2BD3c7nsFKlsA%3D%3D Occurrence Handle10.1067/mva.2000.102592 Occurrence Handle10709062

    Article  CAS  PubMed  Google Scholar 

  34. M Prinssen JD Blankensteijn (2002) ArticleTitleThe sac shrinking process after EAR does not start immediately in most patients Eur J Vasc Endovasc Surg 23 426–430 Occurrence Handle1:STN:280:DC%2BD383ovVeltw%3D%3D Occurrence Handle10.1053/ejvs.2002.1605 Occurrence Handle12027470

    Article  CAS  PubMed  Google Scholar 

  35. NS Cayne FJ Veith EC Lipsitz et al. (2004) ArticleTitleVariability of maximal aortic aneurysm diameter measurements on CT scan: Significance and methods to minimize J Vasc Surg 39 811–815 Occurrence Handle10.1016/j.jvs.2003.11.042 Occurrence Handle15071447

    Article  PubMed  Google Scholar 

  36. KK Yeung MJ Laan Particlevan der JJ Wever et al. (2003) ArticleTitleNew post-imaging software provides fast and accurate volume data from CTA surveillance after endovascular aneurysm repair J Endovasc Ther 10 887–893 Occurrence Handle10.1177/152660280301000507 Occurrence Handle14656186

    Article  PubMed  Google Scholar 

  37. S Nawaratne R Fabiny JE Brien et al. (1997) ArticleTitleAccuracy of volume measurement using helical CT J Comput Assist Tomogr 21 481–486 Occurrence Handle1:STN:280:DyaK2s3otFemtw%3D%3D Occurrence Handle10.1097/00004728-199705000-00027 Occurrence Handle9135663

    Article  CAS  PubMed  Google Scholar 

  38. NJ Aarts GW Schurink U Schultze Kool et al. (1999) ArticleTitleAbdominal aortic aneurysm measurements for endovascular repair: Intra- and interobserver variability of CT measurements Eur J Vasc Endovasc Surg 18 475–480 Occurrence Handle1:STN:280:DC%2BD3c7gsFKgsA%3D%3D Occurrence Handle10.1053/ejvs.1999.0883 Occurrence Handle10637142

    Article  CAS  PubMed  Google Scholar 

  39. T Resch K Ivancev J Brunkwall et al. (2000) ArticleTitleMidterm changes in aortic aneurysm morphology after endovascular repair J Endovasc Ther 7 279–285 Occurrence Handle1:STN:280:DC%2BD3M%2FltVCisw%3D%3D Occurrence Handle10.1177/152660280000700404 Occurrence Handle10958291

    Article  CAS  PubMed  Google Scholar 

  40. GH White J May P Petrasek et al. (1999) ArticleTitleEndotension: An explanation for continued AAA growth after successful endoluminal repair J Endovasc Surg 6 308–315 Occurrence Handle1:STN:280:DC%2BD3czkvFaiuw%3D%3D Occurrence Handle10.1583/1074-6218(1999)006<0308:EAEFCA>2.0.CO;2 Occurrence Handle10893130

    Article  CAS  PubMed  Google Scholar 

  41. GH White (2001) ArticleTitleWhat are the causes of endotension? J Endovasc Ther 8 454–456 Occurrence Handle1:STN:280:DC%2BD3MnntF2htA%3D%3D Occurrence Handle10.1177/152660280100800505 Occurrence Handle11718402

    Article  CAS  PubMed  Google Scholar 

  42. L Engellau U Albrechtsson S Hojgard et al. (2003) ArticleTitleCosts in follow-up of endovascularly repaired abdominal aortic aneurysms: Magnetic resonance imaging with MR angiography versus EUROSTAR protocols Int Angiol 22 36–42 Occurrence Handle1:STN:280:DC%2BD3s3kslKisA%3D%3D Occurrence Handle12771854

    CAS  PubMed  Google Scholar 

  43. PJ Bendick PG Bove GW Long GB Zelenock OW Brown CJ Shanley (2003) ArticleTitleEfficacy of ultrasound scan contrast agents in the noninvasive follow-up of aortic stent grafts J Vasc Surg 37 381–385 Occurrence Handle10.1067/mva.2003.17 Occurrence Handle12563210

    Article  PubMed  Google Scholar 

  44. Napoli V, Bargellini I, Sardella SS, et al (2004) Contrast-enhanced ultrasound in missed endoleaks after endoluminal repair of abdominal aortic aneurysms. Radiology 233:217–225

    Article  PubMed  Google Scholar 

  45. B Sonesson N Dias M Malina P Olofsson et al. (2003) ArticleTitleIntra-aneurysm pressure measurements in successfully excluded abdominal aortic aneurysm after endovascular repair J Vasc Surg 37 733–738 Occurrence Handle10.1067/mva.2003.138 Occurrence Handle12663970

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Irene Bargellini.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Bargellini, I., Cioni, R., Petruzzi, P. et al. Endovascular Repair of Abdominal Aortic Aneurysms: Analysis of Aneurysm Volumetric Changes at Mid-Term Follow-Up. Cardiovasc Intervent Radiol 28, 426–433 (2005). https://doi.org/10.1007/s00270-004-0171-9

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00270-004-0171-9

Keywords

Navigation