Abstract
Background
Laparoscopic ventral hernia repair (LVHR) has been reported to have lower recurrence rates, fewer surgical site infections, and shorter hospital stays compared to open repair. Despite improved surgical outcomes with standard LVHR (sLVHR), seroma formation, eventration (or bulging of mesh or tissue), and hernia recurrence remain common complications. Our objective was to evaluate outcomes with trans-cutaneous closure of central defects in LVHR compared to sLVHR.
Methods
A retrospective review of 176 patients who underwent elective LVHR between January 2007 and December 2010 was performed. Of the 176 patients, 36 (20.5 %) had the LVHR-TCCD (trans-cutaneous closure of central defects) procedure and 140 (79.5 %) had sLVHR. The LVHR-TCCD cases were compared to a 1:1 case-matched control (n = 36). The case control group was matched by hernia type (primary versus secondary), hernia size, Ventral Hernia Working Group (VHWG) grade, institution, and follow-up duration. Patient demographics, co-morbidities, hernia characteristics, operative details, imaging data, and complications were collected. Patient satisfaction (using a 10-point, Likert-type scale), late postoperative pain (using the visual analogue scale), and patient functional status (using the Activities Assessment Scale; AAS) were analyzed. Continuous data were analyzed with either the unpaired Student’s t test or the Mann–Whitney U-test, while Fischer’s exact test was used to compare categorical data.
Results
Patient demographics, co-morbidities, hernia size, hernia type, mesh type, and surgical histories were similar between the LVHR-TCCD group and the case control group. The LVHR-TCCD patients had significantly lower rates of seroma formation (5.6 % versus 27.8 %; p = 0.02), mesh eventration (0.0 % versus 41.4 %; p = 0.0002), tissue eventration (4.0 % versus 37.9 %; p = 0.003), clinical eventration (8.3 % versus 69.4 %; p = 0.0001), and hernia recurrence (0.0 % versus 16.7 %; p = 0.02) when compared to the sLVHR case control. Postoperative infectious complications and early complications classified by the Dindo-Clavien system were similar between the groups. Median follow-up was 24 months (range: 7–34 months) for both groups. Compared to the case control group, patients having undergone LVHR-TCCD had higher patient satisfaction scores (8.8 ± 0.4 versus 7.0 ± 0.5; p = 0.008), cosmetic satisfaction scores (8.8 ± 0.4 versus 7.0 ± 0.6; p = 0.01), and AAS functional status scores (79.1 ± 1.9 versus 71.3 ± 2.3; p = 0.002). There was no difference in worst pain scores or the prevalence of chronic pain.
Conclusions
The incidence of seroma, mesh and tissue eventration, and hernia recurrence was significantly lower following LVHR-TCCD when compared to sLVHR. Subjective improvement in overall patient satisfaction, cosmetic satisfaction, and functional status was reported with closing the central defect. The LVHR-TCCD technique may be superior for treating ventral hernias due to lower complication rates and higher patient satisfaction and functional status.
Similar content being viewed by others
References
Mudge M, Hughes LE (1985) Incisional hernia: a 10 year prospective study of incidence and attitudes. Br J Surg 72:70–71
Hesselink VJ, Luijendijk RW, de Wilt JH et al (1993) An evaluation of risk factors in incisional hernia recurrence. Surg Gynecol Obstet 176:228–234
Luijendijk RW, Hop WC, van den Tol MP et al (2000) A comparison of suture repair with mesh repair for incisional hernia. N Engl J Med 343:392–398
Burger JW, Luijendijk RW, Hop WC et al (2004) Long-term follow-up of a randomized controlled trial of suture versus mesh repair of incisional hernia. Ann Surg 240:578–585
Saber AA, Elgamal MH, Mancl TB et al (2008) Advanced age: is it an indication or contraindication for laparoscopic ventral hernia repair? J Soc Laparoendosc Surg 12:46–50
Read RC, Yoder G (1989) Recent trends in the management of incisional herniation. Arch Surg 124:485–488
Flum DR, Horvath K, Koepsell T (2003) Have outcomes of incisional hernia repair improved with time? A population-based analysis. Ann Surg 237:129–135
Kaafarani HM, Hur K, Hirter A et al (2009) Seroma in ventral incisional herniorrhaphy: incidence, predictors and outcome. Am J Surg 198:639–644
Kaafarani HM, Kaufman D, Reda D et al (2010) Predictors of surgical site infection in laparoscopic and open ventral incisional herniorrhaphy. J Surg Res 163:229–234
Poulose BK, Shelton J, Phillips S et al (2011) Epidemiology and cost of ventral hernia repair: making the case for hernia research. Hernia 16:179–183
Breuing K, Butler CE, Ferzoco S et al (2010) Incisional ventral hernias: review of the literature and recommendations regarding the grading and technique of repair. Surgery 148:544–558
Rutkow IM (2003) Demographic and socioeconomic aspects of hernia repair in the United States in 2003. Surg Clin North Am 83:1045–1051, v–vi
Sanchez LJ, Bencini L, Moretti R (2004) Recurrences after laparoscopic ventral hernia repair: results and critical review. Hernia 8:138–143
Sauerland S, Walgenbach M, Habermalz B et al. (2011) Laparoscopic versus open surgical techniques for ventral or incisional hernia repair. Cochrane Database Syst Rev 2011Mar16;(3):CD007781
Heniford T, Park A, Ramshaw BJ et al (2000) Laparoscopic hernia repair in 407 patients. Am Coll Surg 190:645–650
Itani KM, Hur K, Kim LT (2010) Comparison of laparoscopic and open repair with mesh for the treatment of ventral incisional hernia: a randomized trial. Arch Surg 145:322–328
Kurmann A, Visth E, Candinas D et al (2011) Long-term follow-up of open and laparoscopic repair of large incisional hernias. World J Surg 35:297–301. doi:10.1007/s00268-010-0874-9
Hawn MT, Snyder CW, Graham LA et al (2010) Long-term follow-up of technical outcomes for incisional hernia repair. J Am Coll Surg 210:648–655
Asencio F, Aguiló J, Peiró S et al (2009) Open randomized clinical trial of laparoscopic versus open incisional hernia repair. Surg Endosc 23:1441–1448
Pring CM, Tran V, O’Rourke N et al (2008) Laparoscopic versus open ventral hernia repair: a randomized controlled trial. Aust N Z J Surg 78:903–906
Olmi S, Scaini A, Cesana GC et al (2007) Laparoscopic versus open incisional hernia repair: an open randomized controlled study. Surg Endosc 21:555–559
Barbaros U, Asoglu O, Seven R et al (2007) The comparison of laparoscopic and open ventral hernia repairs: a prospective randomized study. Hernia 11:51–56
Misra MC, Bansal VK, Kulkarni MP et al (2006) Comparison of laparoscopic and open repair of incisional and primary ventral hernia: results of a prospective randomized study. Surg Endosc 20:1839–1845
Carbajo MA, del Olmo JC, Blanco JI et al (2000) Laparoscopic treatment of ventral abdominal wall hernias: preliminary results in 100 patients. J Soc Laparoendosc Surg 4:141–145
Tse GH, Stutchfield BM, Duckworth AD et al (2010) Pseudo-recurrence following laparoscopic ventral and incisional hernia repair. Hernia 14:583–587
Bencini L, Sanchez LJ, Bernini M et al (2009) Predictors of recurrence after laparoscopic ventral hernia repair. Surg Laparosc Endosc Percut Tech 19:128–132
Franklin ME Jr, Gonzalez JJ Jr, Glass JL et al (2004) Laparoscopic ventral and incisional hernia repair: an 11-year experience. Hernia 8:23–27
Heniford BT, Park A, Ramshaw BJ et al (2003) Laparoscopic repair of ventral hernias: nine years’ experience with 850 consecutive hernias. Ann Surg 238:391–399
Carbajo MA, Martp del Olmo JC, Blanco JI et al (2003) Laparoscopic approach to incisional hernia. Surg Endosc 17:118–122
Rosen M, Brody F, Ponsky J et al (2003) Recurrence after laparoscopic ventral hernia repair. Surg Endosc 17:123–128
LeBlanc KA, Whitaker JM, Bellanger DE et al (2003) Laparoscopic incisional and ventral hernioplasty: lessons learned from 200 patients. Hernia 7:118–124
LeBlanc KA, Booth WV (1993) Laparoscopic repair of incisional abdominal hernias using expanded polytetrafluoroethylene: preliminary findings. Surg Laparosc Endosc 3:39–41
Liang MK, Subramanian A, Awad SS (2012) Laparoscopic trans-cutaneous closure of central defects in laparoscopic incisional hernia repair. Surg Laparosc Endsc Percut Tech (in press)
Liang MK, Subramanian A, Awad SS (2011) Laparoscopic Trans-cutaneous closure of central defects in laparoscopic incisional hernia repair. Unpublished data, presentation and abstract. Association of Veterans Affairs Surgeons
Agarwal BB, Agarwal S, Gupta MK et al (2008) Laparoscopic ventral hernia meshplasty with “double-breasted” fascial closure of hernial defect: a new technique. J Laparoendosc Adv Surg Tech Part A 18:222–229
Agarwal BB, Agarwal S, Mahajan KC (2009) Laparoscopic ventral hernia repair: innovative anatomical closure, mesh insertion without 10-mm transmyofascial port, and atraumatic mesh fixation: a preliminary experience of a new technique. Surg Endosc 23:900–905
Orenstein SB, Dumeer JL, Monteagudo J et al (2011) Outcomes of laparoscopic ventral hernia repair with routine defect closure using “shoelacing” technique. Surg Endosc 25:1452–1457
http://www.cdc.gov/nhsn/PDFs/pscManual/9pscSSIcurrent.pdf. Accessed 11/18/2011
Dindo D, Demartines N, Clavien P (2004) Classification of surgical complications: a new proposal with evaluation in a cohort of 6336 patients and results of a survey. Ann Surg 240:205–213
McCarthy M Jr, Jonasson O, Chang CH et al (2005) Assessment of patient functional status after surgery. J Am Coll Surg 201:171–178
Agresti A (2002) Categorical data analysis, 2nd edn. Wiley, Hoboken
Kutner MH, Natchtsheim CJ, Neter J et al (2005) Applied linear statistical models, 5th edn. McGraw-Hill Irwin, New York
R Development Core Team (2012) R: a language and environment for statistical computing. Vienna, Austria, R Foundation for Statistical Computing (ISBN 3-900051-07-0; URL http://www.R-project.org/)
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Clapp, M.L., Hicks, S.C., Awad, S.S. et al. Trans-cutaneous Closure of Central Defects (TCCD) in Laparoscopic Ventral Hernia Repairs (LVHR). World J Surg 37, 42–51 (2013). https://doi.org/10.1007/s00268-012-1810-y
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00268-012-1810-y