Electrical identification and monitoring of the recurrent laryngeal nerve (RLN) has been proposed as an adjunct to standard visual identification of the nerve during thyroid and parathyroid surgery. This study was undertaken to assess laryngeal palpation as an intraoperative technique for identifying and assessing the RLN during surgery and to investigate the relation between laryngeal palpation and associated laryngeal electromyographic (EMG) activity. The postcricoid region of the larynx during surgery was palpated through the posterior hypopharyngeal wall to sense posterior cricoarytenoid muscle contraction in response to ipsilateral RLN stimulation (i.e., the “laryngeal twitch response.”) Laryngeal palpation was performed in a series of 449 consecutive thyroid and parathyroid surgeries with 586 RLNs at risk. All patients underwent preoperative and postoperative laryngoscopy to assess vocal cord mobility. In a subset of patients, laryngeal palpation and simultaneous laryngeal EMG recordings were compared during intraoperative RLN stimulation. In this series, there was no permanent RLN paralysis. There was one case of temporary RLN paralysis secondary to neural stretch that resolved 6 weeks postoperatively (temporary paralysis rate: 0.2% of patients, 0.2% of nerves at risk). Intraoperative laryngeal palpation of the laryngeal twitch response reliably correlated with normal postoperative vocal cord function. Loss of the laryngeal twitch response occurred in the single case of temporary paralysis in the setting of an anatomically intact nerve. Laryngeal palpation correlated well with simultaneous laryngeal EMG activity. There were no palpation-induced laryngeal injuries or laryngeal edema. There were also no RLN injuries due to repetitive neural stimulation. Intraoperative laryngeal palpation during RLN stimulation is a safe, reliable method for neural monitoring that can assist in RLN identification and assessment during thyroid and parathyroid surgery. Most importantly, it provides important prognostic information regarding ipsilateral vocal cord function at the completion of the initial side of the thyroid or parathyroid surgery. Intraoperative laryngeal palpation allows the surgeon to stage contralateral surgery if RLN damage is diagnosed, thereby avoiding the potential for bilateral vocal cord paralysis. We believe that laryngeal palpation is useful as an adjunct to formal EMG monitoring during thyroid and parathyroid surgery.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1.
Fig. 2.
Fig. 3.

Similar content being viewed by others

References

  1. Munch S, DeKryger L. Moral wounds: complicated complications. J.A.M.A. 2001;9:1131–1132

    Google Scholar 

  2. MB Flynn KJ Lyons JW Tarter et al. (1994) ArticleTitleLocal complications after surgical resection for thyroid carcinoma Am. J. Surg. 168 404–407 Occurrence Handle1:STN:280:ByqD28fmtVY%3D Occurrence Handle7977960

    CAS  PubMed  Google Scholar 

  3. KE Levin AH Clark QY Duh et al. (1992) ArticleTitleReoperative thyroid surgery Surgery 111 604–609 Occurrence Handle1:STN:280:By2B2sbpt1A%3D Occurrence Handle1595056

    CAS  PubMed  Google Scholar 

  4. M Steurer C Passler D-M Denk et al. (2002) ArticleTitleAdvantages of recurrent laryngeal nerve identification in thyroidectomy and parathyroidectomy and the importance and postoperative laryngoscopic examination in more than 1,000 nerves at risk Laryngoscope 112 124–133 Occurrence Handle10.1097/00005537-200201000-00022 Occurrence Handle11802050

    Article  PubMed  Google Scholar 

  5. CY Lo KF Kwoh PW Yuen (2000) ArticleTitleA prospective evaluation of RLN paralysis during thyroidectomy Arch. Surg. 135 204–207 Occurrence Handle10.1001/archsurg.135.2.204 Occurrence Handle1:STN:280:DC%2BD3c7jt1eltA%3D%3D Occurrence Handle10668882

    Article  CAS  PubMed  Google Scholar 

  6. GR Holt GR McMurry DL Joseph (1977) ArticleTitleRLN injury following thyroid operation Surg. Gynecol. Obstet. 144 567–570 Occurrence Handle1:STN:280:CSiC2M7jt1E%3D Occurrence Handle847613

    CAS  PubMed  Google Scholar 

  7. C Patlow J Norton M Brennan (1986) ArticleTitleVocal cord paralysis and reoperative parathyroidectomy Ann. Surg. 203 282–285 Occurrence Handle3954480

    PubMed  Google Scholar 

  8. RW Tsang JD Brierley WJ Simpson et al. (1998) ArticleTitleThe effect of surgery, radioiodine, external radiation treatment on clinical outcome of patients with differentiated thyroid carcinoma Cancer 82 375–388 Occurrence Handle10.1002/(SICI)1097-0142(19980115)82:2<389::AID-CNCR19>3.3.CO;2-E Occurrence Handle1:STN:280:DyaK1c7gsF2ktg%3D%3D Occurrence Handle9445196

    Article  CAS  PubMed  Google Scholar 

  9. HE Wagner C Seiler (1984) ArticleTitleRecurrent laryngeal nerve paralysis after thyroid gland surgery Br. J. Surg. 81 226–288

    Google Scholar 

  10. DB De Roy van Zuidewijn I Songun et al. (1995) ArticleTitleComplications from thyroid surgery Ann. Surg. Oncol. 2 56–60 Occurrence Handle1:STN:280:ByqC3sngsFc%3D Occurrence Handle7834455

    CAS  PubMed  Google Scholar 

  11. H Wanebo N Coburn D Teates et al. (1998) ArticleTitleTotal thyroidectomy does not enhance disease control or survival even in high risk patients with differentiated thyroid carcinoma Ann. Surg. 277 912–921 Occurrence Handle10.1097/00000658-199806000-00015

    Article  Google Scholar 

  12. RS Djohan HE Rodriguez MM Connolly et al. (2000) ArticleTitleIntraoperative monitoring of recurrent laryngeal function Am. Surg. 66 595–597 Occurrence Handle1:STN:280:DC%2BD3M%2Fhs1ahtQ%3D%3D Occurrence Handle10888139

    CAS  PubMed  Google Scholar 

  13. K Segal R Friedental E Lubin et al. (1995) ArticleTitlePapillary carcinoma of the thyroid Otolaryngol. Head Neck Surg. 113 356–363 Occurrence Handle1:STN:280:BymD3M7ntFE%3D Occurrence Handle7567004

    CAS  PubMed  Google Scholar 

  14. GR Jatzko PH Lisborg MG Muller et al. (1994) ArticleTitleRecurrent laryngeal nerve palsy after thyroid operations: principle nerve identification and literature review Surgery 115 139–144 Occurrence Handle1:STN:280:ByuC2czosFc%3D Occurrence Handle8310401

    CAS  PubMed  Google Scholar 

  15. KA Kern (1995) ArticleTitleThe anatomy of surgical malpractice claims Bull. Am. Coll. Surg. 80 35–49

    Google Scholar 

  16. KA Kern (1993) ArticleTitleMedical legal analysis in the diagnosis and treatment of surgical endocrine disease Surgery 114 1167–1174 Occurrence Handle1:STN:280:ByuD2sfis1E%3D Occurrence Handle8256224

    CAS  PubMed  Google Scholar 

  17. T Hvidegaard et al. (1983) ArticleTitleIdentification and functional recording of the recurrent laryngeal nerve by electrical stimulation during neck surgery Laryngoscope 93 370–373 Occurrence Handle1:STN:280:BiyC28nis1M%3D Occurrence Handle6834963

    CAS  PubMed  Google Scholar 

  18. GW Randolph (2003) Surgical anatomy of the recurrent laryngeal nerve GW Randolph (Eds) Surgery of the Thyroid and Parathyroid Glands Saunders Philadelphia 300–342

    Google Scholar 

  19. O Thomusch C Sekulla G Walls et al. (2002) ArticleTitleIntraoperative neural monitoring in surgery for benign goiter Am. J. Surg. 183 673–678 Occurrence Handle10.1016/S0002-9610(02)00856-5 Occurrence Handle12095600

    Article  PubMed  Google Scholar 

  20. JW Goodnight et al. (1995) ArticleTitleCorrelation of compound action potential and electromyography and facial muscle tension Otolaryngol. Head Neck Surg. 112 279–290 Occurrence Handle1:STN:280:ByqC2c%2FksV0%3D Occurrence Handle7838553

    CAS  PubMed  Google Scholar 

  21. M Mermelstein R Weiler Particlevon EH Rubinstein (1996) ArticleTitleIntraoperative identification of laryngeal nerves with laryngeal electromyography Laryngoscope 106 752–756 Occurrence Handle10.1097/00005537-199606000-00016 Occurrence Handle1:STN:280:BymB2cjjsFY%3D Occurrence Handle8656962

    Article  CAS  PubMed  Google Scholar 

  22. JL Rea A Khan (1994) ArticleTitleRecurrent laryngeal nerve localization in thyroid and parathyroid surgery: use of an indwelling laryngeal surface electrode with evoked electromyography Op. Tech. Otolaryngol. Head Neck Surg. 5 91–96 Occurrence Handle10.1016/1043-1810(94)90042-6

    Article  Google Scholar 

  23. GW Randolph et al. (1996) ArticleTitleComparison of intraoperative recurrent laryngeal nerve monitoring techniques during recurrent laryngeal nerve surgery Otolaryngol. Head Neck Surg. 115 102

    Google Scholar 

  24. JL Rea A Khan (1998) ArticleTitleClinical evoked EMG for recurrent laryngeal nerve preservation: use of endotracheal tube electrode and a post cricoid surface electrode Laryngoscope 108 1418–1420 Occurrence Handle10.1097/00005537-199809000-00032 Occurrence Handle1:STN:280:DyaK1cvgvFWmsg%3D%3D Occurrence Handle9738770

    Article  CAS  PubMed  Google Scholar 

  25. J Leonetti VP Mokarry Z Fan et al. (1994) ArticleTitleVagal nerve monitoring during parapharyngeal space tumor removal Skull Base Surg. 4 213–218

    Google Scholar 

  26. DP Shedd GC Burget (1966) ArticleTitleIdentification of the recurrent laryngeal nerve: electrical method for evaluation in the human Arch. Surg. 25 861–864

    Google Scholar 

  27. V Riddell (1970) ArticleTitleThyroidectomy: prevention of bilateral recurrent laryngeal nerve palsy: results of identification of the nerve over 23 consecutive years (46-60) with description of an additional safety measure Br. J. Surg. 57 1–11 Occurrence Handle1:STN:280:CS%2BD1cjovFE%3D Occurrence Handle5411583

    CAS  PubMed  Google Scholar 

  28. AG James S Crocker E Woltering et al. (1985) ArticleTitleA simple method for identifying and testing the recurrent laryngeal nerve Surg. Gynecol. Obstet. 161 185–186 Occurrence Handle1:STN:280:BiqB2szgtFA%3D Occurrence Handle4023901

    CAS  PubMed  Google Scholar 

  29. J Galivan C Galivan (1986) ArticleTitleRLN identification during thyroid and parathyroid surgery Arch. Otolaryngol. Head Neck Surg. 112 1286–1288 Occurrence Handle3768155

    PubMed  Google Scholar 

  30. A Echeverri P Flexon (1998) ArticleTitleElectrophysiologic nerve stimulation for identification of recurrent laryngeal nerve in thyroid surgery: review of 70 consecutive thyroid surgeries Am. Surg. 64 328–333 Occurrence Handle1:STN:280:DyaK1c3gsFOhtw%3D%3D Occurrence Handle9544143

    CAS  PubMed  Google Scholar 

  31. JK Niparko PR Mleny IL Kermink et al. (1989) ArticleTitleNeurophysiologic intraoperative monitoring. II. Facial nerve function Am. J. Otol. 10 55–61 Occurrence Handle10.1016/0196-0709(89)90092-6 Occurrence Handle1:STN:280:BiaB2cvptFI%3D Occurrence Handle2655465

    Article  CAS  PubMed  Google Scholar 

  32. PE Hammerschlag MC Cohen (1990) ArticleTitleIntraoperative monitoring of facial nerve function in cerebellopontine angle surgery Otolaryngol. Head Neck Surg. 103 681–684 Occurrence Handle1:STN:280:By6C3MjksVY%3D Occurrence Handle2126086

    CAS  PubMed  Google Scholar 

  33. JE Terrel PR Kileny C Yian et al. (1997) ArticleTitleClinical outcomes of continuous VIIth nerve monitoring during primary parotidectomy Arch. Otolaryngol. Head Neck Surg. 123 1081–1087 Occurrence Handle9339985

    PubMed  Google Scholar 

  34. Wolf SR, Schneider W, Suchy B, et al. Intraoperative facial nerve monitoring in parotid surgery. H.N.O. 1995;43:294–298

    Google Scholar 

  35. JP Leonetti DE Brackmann RL Prass (1999) ArticleTitleImproved preservation of facial nerve function in the infratemporal approach to the skull base Otolaryngol. Head Neck Surg. 101 74–78

    Google Scholar 

Download references

Acknowledgments.

This study was funded in part by the Bart Guerreri Thyroid Surgical Research Fund

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Gregory W. Randolph M.D..

Rights and permissions

Reprints and permissions

About this article

Cite this article

Randolph, G., Kobler, J. & Wilkins, J. Recurrent Laryngeal Nerve Identification and Assessment during Thyroid Surgery: Laryngeal Palpation. World J. Surg. 28, 755–760 (2004). https://doi.org/10.1007/s00268-004-7348-x

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00268-004-7348-x

Keywords

Navigation