The fracture or defect of the mandibular condyle is one of the serious complications during angle-reduction ostectomy. Reconstruction of such defects also is a daunting task. The case report describes a method based on computer-aided design/computer-aided manufacturing (CAD/CAM) and rapid prototyping nanoscale hydroxyapatite/polyamide (n-HA/PA) for individual design, fabrication, and implantation of a mandibular condyle. A 27-year-old woman with a square-shaped face who had previously undergone mandibular angle reduction reported with malocclusion, deviated mouth, collapse of the right side of the face, and masticatory problems. The reason for the problems was the unintended removal of the condyle during the ostectomy procedure. Using computed tomography (CT) data, a biomimetic n-HA/PA scaffold, and CAD/CAM for rapid prototyping by three-dimensional (3D) printing, a perfect-fitting condylar implant was fabricated. A surgical guide system also was developed to reproduce the procedures accurately so a perfect fit could be obtained during surgery. The patient ultimately regained reasonable jaw contour and appearance, as well as appreciable temporomandibular joint (TMJ) function.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5

References

  1. Baek SM (1989) The prominent mandibular angle: preoperative management, operative technique, and results in 42 patients. Plast Reconstr Surg 83:272–278

    Article  PubMed  CAS  Google Scholar 

  2. Yang DB, Park CG (1991) Mandibular contouring surgery for purely aesthetic reasons. Aesth Plast Surg 15:53–60

    Article  CAS  Google Scholar 

  3. Park SH, Kim HS, Kin JT (1998) New approach of mandibular angle resection. J Korean Soc Aesthetic Plast Surg 4:72–79

    CAS  Google Scholar 

  4. Deguchi M, Iio Y (1997) Angle-splitting ostectomy for reducing the width of the lower face. Plast Reconstr Surg 99:1831–1839

    Article  PubMed  CAS  Google Scholar 

  5. Oh YW, Han KT, Ahn ST et al (1990) The complication of mandibular angle reduction. J Korean Soc Plast Reconstr Surg 17:645–652

    Google Scholar 

  6. Hwang K, Han JY, Kil MS et al (2002) Treatment of condyle fracture caused by mandibular angle ostectomy. J Craniofac Surg 3:709–712

    Article  Google Scholar 

  7. Agrawal CM, Ray RB (2001) Biodegradable polymeric scaffolds for musculoskeletal tissue engineering. J Biomed Mater Res 55:141–150

    Article  PubMed  CAS  Google Scholar 

  8. Eufinger H, Wehmoller M, Machtens E et al (1995) Reconstruction of craniofacial bone defects with individual alloplastic implants based on CAD/CAM-manipulated CT-data. J Craniomaxillofac Surg 23:175–181

    Article  PubMed  CAS  Google Scholar 

  9. Wei J, Li Y (2004) Tissue engineering scaffold material of nano-apatite crystals and polyamide composite. Eur Polymer J 40:509–515

    Article  CAS  Google Scholar 

  10. Yubao L, Yi Z, Jie W (2003) Preparation of nano-hydroxyapatite/polyamide composite biomaterial. China Patent No. CNZL200310111033.5

  11. Wang H, Li Y, Zuo Y, Li J, Ma S, Cheng L (2007) Biocompatibility and osteogenesis of biomimetic nano-hydroxyapatite/polyamide composite scaffolds for bone tissue engineering. Biomaterials 28:3338–3348

    Article  PubMed  CAS  Google Scholar 

  12. Ellis E, Reynolds ST, Park HS (1989) A method to rigidly fix high condylar fractures. Oral Surg 68:369–374

    Article  PubMed  Google Scholar 

  13. Boyne PJ (1989) Free grafting of traumatically displaced or resected mandibular condyles. J Oral Maxillofac Surg 47:228–232

    Article  PubMed  CAS  Google Scholar 

  14. Morris CL, Barber RF, Day R (2000) Orofacial prosthesis design and fabrication using stereolithography. Aust Dent J 45:250–253

    Article  PubMed  CAS  Google Scholar 

  15. Winder J, Cooke RS, Gray J, Fannin T, Fegan T (1999) Medical rapid prototyping and 3D CT in the manufacture of custom made cranial titanium plates. J Med Eng Technol 23:26–28

    Article  PubMed  CAS  Google Scholar 

  16. Samman N, Luk WK, Chow TW, Cheung LK, Tideman H, Clark RKF (1999) Custom made titanium mandibular reconstuction tray. Aust Dental J 44:195–199

    Article  CAS  Google Scholar 

  17. Sachlos E, Czernuska JT (2003) Making tissue engineering scaffolds work: review on the application of solid freeform fabrication technology to the production of tissue engineering scaffolds. Eur Cells Mater 5:29–40

    CAS  Google Scholar 

  18. Kong L, Ao Q, Wang A, Gong K, Wang X, Lu G et al (2007) Preparation and characterization of a multilayer biomimetic scaffold for bone tissue engineering. J Biomater Appl 22:223–239

    Article  PubMed  CAS  Google Scholar 

  19. Gibson I, Cheung LK, Chow SP, Cheung WL, Beh SL, Savalani M (2006) The use of rapid prototyping to assist medical applications. Rapid Prototyping J 12:53–58

    Article  Google Scholar 

  20. Cesarano J, Dellinger JG, Saavedra MP, Gill DD, Jamison RD, Grosser BA (2005) Customization of load-bearing hydroxyapatite lattice scaffolds. Int J Appl Ceram Technol 2:212–220

    Article  CAS  Google Scholar 

Download references

Acknowledgments

This study was supported by Natural Science Foundation of China (30400506) and China 973 funds (2007CB936102).

Conflict of interest

None.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Jihua Li.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Li, J., Hsu, Y., Luo, E. et al. Computer-Aided Design and Manufacturing and Rapid Prototyped Nanoscale Hydroxyapatite/Polyamide (n-HA/PA) Construction for Condylar Defect Caused by Mandibular Angle Ostectomy. Aesth Plast Surg 35, 636–640 (2011). https://doi.org/10.1007/s00266-010-9602-y

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00266-010-9602-y

Keywords

Navigation