Abstract
Purpose
The treatment of vertical femoral neck fractures in young patients is a worldwide challenge. The purpose of this study is to introduce a new configuration of cannulated screw fixation in vertical femoral neck fractures by comparing with using ordinary cannulated compression screw (OCCS) alone biomechanically and clinically.
Material and method
Biomechanically, 20 synthetic femur models of femoral neck fractures with 20° of VN angle were divided into two groups. The first group was fixed with three ordinary cannulated compression screws defined as OCCS group; the second group was fixed with two Headless Cannulated Compression Screws (HCCS) plus an OCCS, defined as combination group and tested for axial stiffness and load to failure. Clinically, a prospective study was designed with 59 patients who have vertical femoral neck fractures and were treated with cannulated screw, including 31 patients with three ordinary cannulated compression screws alone and 28 patients with an ordinary cannulated compression screw plus two headless cannulated compression screws.
Results
Biomechanically, our results showed that there was no significant difference of axial stiffness between OCCS group and combination group (109.92 ± 10.81 vs. 123.49 ± 15.13 N/mm, P = 0.145). But, the maximum load to failure of the combination group performed significant advantages than that of the OCCS group (446.85 ± 76.25 vs. 302.92 ± 80.46 N, P = 0.007). Clinically, the rates of fixation failure in the group treated with OCCS alone were 41.9%, while in the group treated with two types of screws were14.3% (P = 0.048).
Conclusion
Our results suggested that using new configuration of an OCCS plus two HCCSs improved the outcome of vertical femoral neck fractures (FNF) patients compared to those using OCCS alone, which provides a new choice for treatment of FNF.
Similar content being viewed by others
References
Liporace F, Gaines R, Collinge C, Haidukewych GJ (2008) Results of internal fixation of Pauwels type-3 vertical femoral neck fractures. J Bone Joint Surg Am 90(8):1654–1659
Haidukewych GJ, Rothwell WS, Jacofsky DJ, Torchia ME, Berry DJ (2004) Operative treatment of femoral neck fractures in patients between the ages of fifteen and fifty years. J Bone Joint Surg Am 86:1711–1716
Saglam N, Kucukdurmaz F, Kivilcim H, Kurtulmus T, Sen C, Akpinar F (2014) Biomechanical comparison of antirotator compression hip screw and cannulated screw fixations in the femoral neck fractures. Acta Orthop Traumatol Turc 48:196–201
Lee YS, Chen SH, Tsuang YH, Huang HL, Lo TY, Huang CR (2008) Internal fixation of undisplaced femoral neck fractures in the elderly: a retrospective comparison of fixation methods. J Trauma 64:155–162
van Embden D, Roukema GR, Rhemrev SJ, Genelin F, Meylaerts SA (2011) The Pauwels classification for intracapsular hip fractures: is it reliable? Injury 42:1238–1240
Zhang YL, Zhang W, Zhang CQ (2017) A new angle and its relationship with early fixation failure of femoral neck fractures treated with three cannulated compression screws. Orthop Traumatol Surg Res 103(2):229–234
Nowotarski PJ, Ervin B, Weatherby B, Pettit J, Goulet R, Norris B (2012) Biomechanical analysis of a novel femoral neck locking plate for treatment of vertical shear Pauwel’s type C femoral neck fractures. Injury 43:802–806
Rupprecht M, Grossterlinden L, Ruecker AH, de Oliveira AN, Sellenschloh K, Nuchtern J, Puschel K, Morlock M, Rueger JM, Lehmann W (2011) A comparative biomechanical analysis of fixation devices for unstable femoral neck fractures: the Intertan versus cannulated screws or a dynamic hip screw. J Trauma 71:625–634
Huang TW, Hsu WH, Peng KT, Lee CY (2011) Effect of integrity of the posterior cortex in displaced femoral neck fractures on outcome after surgical fixation in young adults. Injury 42:217–222
Zlowodzki M, Brink O, Switzer J, Wingerter S, Woodall J Jr, Petrisor BA, Kregor PJ, Bruinsma DR, Bhandari M (2008) The effect of shortening and varus collapse of the femoral neck on function after fixation of intracapsular fracture of the hip: a multi-centre cohort study. J Bone Joint Surg Br 90:1487–1494
Ficat RP (1985) Idiopathic bone necrosis of the femoral head. Early diagnosis and treatment. J Bone Joint Surg Br 67:3–9
Collinge CA, Mir H, Reddix R (2014) Fracture morphology of high shear angle “vertical” femoral neck fractures in young adult patients. J Orthop Trauma 28:270–275
Enocson A, Lapidus LJ (2012) The vertical hip fracture—a treatment challenge. A cohort study with an up to 9-year follow-up of 137 consecutive hips treated with sliding hip screw and antirotation screw. BMC Musculoskelet Disord 13:171
Freitas A, Maciel RA, Lima Rde A, Souto DR, Ferrer Mde A (2014) Mechanical analysis of femoral neck fracture fixation with dynamic condylar screw in synthetic bone. Acta Ortop Bras 22:264–268
Selvan VT, Oakley MJ, Rangan A, Al-Lami MK (2004) Optimum configuration of cannulated hip screws for the fixation of intracapsular hip fractures: a biomechanical study. Injury 35:136–141
Warschawski Y, Sharfman ZT, Berger O, Steinberg EL, Amar E, Snir N (2016) Dynamic locking plate vs. simple cannulated screws for nondisplaced intracapsular hip fracture: a comparative study. Injury 47:424–427
Aminian A, Gao F, Fedoriw WW, Zhang LQ, Kalainov DM, Merk BR (2007) Vertically oriented femoral neck fractures: mechanical analysis of four fixation techniques. J Orthop Trauma 21:544–548
Fowler JR, Ilyas AM (2010) Headless compression screw fixation of scaphoid fractures. Hand Clin 26(3):351–361
Capelle JH, Couch CG, Wells KM, Morris RP, Buford WL Jr, Merriman DJ, Panchbhavi VK (2013) Fixation strength of anteriorly inserted headless screws for talar neck fractures. Foot Ankle Int 34(7):1012–1016
Acknowledgments
We thank the staff of Sports Biomechanics Laboratory in Shanghai Jiao Tong University Affiliated Sixth People’s Hospital and colleagues who provided us a lot of useful inspiration.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors report no proprietary or commercial interest in any product mentioned or concept discussed in this article and no conflict outside the current study.
Rights and permissions
About this article
Cite this article
Zhang, B., Liu, J., Zhu, Y. et al. A new configuration of cannulated screw fixation in the treatment of vertical femoral neck fractures. International Orthopaedics (SICOT) 42, 1949–1955 (2018). https://doi.org/10.1007/s00264-018-3798-x
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00264-018-3798-x