Abstract
Introduction
Since 1979 the number of patients treated with femoral stems has continued to grow, as well as the number of stems with features similar to the Zweymüller prosthesis produced by different companies. Identification can be problematic in case requiring revision. In the present paper, we present an overview of morphometric differences between the different stem designs, which can be useful for radiologic identification in revision cases.
Methods
By doing some research on the Internet of specialized sites and worldwide literature, we searched for all femoral stems agreeing with Zweymüller principles (cementless, straight, tapered, rectangular cross-sectioned femoral stems).
Results
We found 26 different stems from different companies producing or having produced in the past the Zweymüller-type femoral stems for hip prosthesis.
Discussion
Accurate preoperative identification of the Zweymüller femoral stem type may be of critical importance to eventual outcomes following revision surgery. Each manufacturer has different instruments specific to the removal of their primary implants, and ensuring they are available can simplify the revision procedure significantly. Exact pre-operative planning is also necessary for selecting the correct ball head in cases where a stem is well-fixed and can be left in situ. The commonly used notation "Eurocone 12/14" provides no information about the actual taper angle. Whenever the stem is left in situ, the exact specifications of the taper must therefore be obtained from the manufacturer in order to use a metal sleeve that precisely fits it and the ball head. Failure to do so may result in severe complications, such as metallosis. In cases where it is not possible to identify the taper angle, the surgeon may even consider removal of the stem, though this significantly increases the surgical procedure's invasiveness. Only a single, uniform standard taper, such as that offered until 1994 by CeramTec, can solve these issues in the future.
Conclusion
The survival rate of the Zweymüller stems after ten years was 96 % and the complication rate was very low. Pre-operative identification of the femoral implant is of considerable importance for planning and correctly implementing revision procedures.
Similar content being viewed by others
References
Engh CA Jr, Claus AM, Hopper RH Jr, Engh CA (2001) Long-term results using the anatomic medullary locking hip prosthesis. Clin Orthop Relat Res 393:137–146
Rajaratnam SS, Jack C, Tavakkolizadeh A, George MD, Fletcher RJ, Hankins M, Shepperd JA (2008) Long-term results of a hydroxyapatite-coated femoral component in total hip replacement: a 15- to 21-year follow-up study. J Bone Joint Surg (Br) 90(1):27–30
Vidalain JP (2011) Twenty-year results of the cementless Corail stem. Int Orthop 35(2):189–194
Evola FR, Evola G, Graceffa A et al (2014) Performance of the CLS Spotorno uncemented stem in the third decade after implantation. Bone Joint J 96(4):455–461
Lord G, Bancel P (1983) The madreporic cementless total hip arthroplasty: new experimental data and a seven-year clinical follow-up study. Clin Orthop Relat Res 176:67–76
Delaunay C, Cazeau C, Kapandji AI (1998) Cementless primary total hip replacement. Four to eight year results with the Zweymüller-alloclassic prosthesis. Int Orthop 22:1–5
Zweymüller K (1986) A cementless titanium hip endoprosthesis system based on press-fit fixation: basic research and clinical results. Instr Course Lect 35:203–225
Swanson TV (2005) The tapered press fit total hip arthroplasty: a European alternative. J Arthroplast 20:63–67
Inc. WMT (2003) How the history of Zweymuller hips led to the design of the Profemur® Z total hip system. In: Internal Report. http://www.thegreatdictator.com/cgi-bin/boardware/arch.cgi?board=word&page=hioh&file=jolnlomkbj. Accessed 20 Jul 2015
Zweymüller K (1984) First clinical experience with an uncemented modular femoral prosthesis system with a wrought Ti-6 Al-4 V stem and an Al2 0 3 ceramic head. In: Morscher E (ed) The cementless fixation of hip endoprostheses. Springer, Berlin Heidelberg, pp 150–155
Zweymüller K, Semlitsch M (1982) Concept and material properties of a cementless hip prosthesis system with Al2O3 ceramic ball heads and wrought Ti-6Al-4V Stems. Arch Orthop Trauma Surg 100(4):229–236. doi:10.1007/BF00381662
Mohajer MA, Hofmann F, Graf R (2010) Retrospective and consecutive analysis of the long-term outcomes of the SBG stem: a 15-year follow-up study. Arch Orthop Trauma Surg 130(2):185–190
Wright C, Lambert D, Brazil D, Keggi K, Keggi J, McTighe T (2011) Clinical review of the Zweymuller femoral stem. Reconstructive Review 1(1):41–52
EndlerJr M, Endler F, PlenkJr H (1984) Experimental and early clinical experience with an uncemented UHMW polyethylene acetabular prosthesis. In: Morscher E (ed) The cementless fixation of hip endoprostheses. Springer, Berlin Heidelberg, New York, Tokyo, pp 191–199
Zweymüller KA, Lintner FK, Semlitsch MF (1988) Biologic fixation of a press-fit titanium hip joint endoprosthesis. Clin Orthop Relat Res 235:195–206
Vervest TMJS, Anderson PG, Van Hout F et al (2005) Ten to twelve-year results with the Zweymuller cementless total hip prosthesis. J Arthroplasty 20:362–368. doi:10.1016/j.arth.2004.11.017
Zweymüller K (2008) Good results with an uncoated grit-blasted tapered straight stem at ten years. Interact Surg 2(3–4):197–205. doi:10.1007/s11610-007-0063-1
Ottink K, Barnaart L, Westerbeek R et al (2015) Survival, clinical and radiological outcome of the Zweymüller SL/Bicon-Plus total hip arthroplasty: a 15-year follow-up study. Hip Int 25(3):204–208. doi:10.5301/hipint.5000231
Studers P, Belajevs D, Jurkevics V, Likums P (2015) Ten to fifteen-year clinical and radiographic follow-up with a third-generation cementless stem in a young patient population. Int Orthop. doi:10.1007/s00264-015-2846-z
OrthopaedicLIST.com (2015) Welcome to OrthopaedicLIST.com | orthopaediclist.com. http://www.orthopaediclist.com/. Accessed 20 Jul 2015
Medcompare (2015) Medcompare is no longer online. http://www.medcompare.com/sunset/medcompare.html. Accessed 20 Jul 2015
Prymka M, Vogiatzis M, Hassenpflug J (2004) Primary rotatory stability of hip endoprostheses stems after manual and robot assisted implantation. Z Orthop Grenzgeb 142(3):303–308. doi:10.1055/s-2004-822666
Traulsen FC, Hassenpflug J, Hahne HJ (2001) Long-term results with cement-free total hip prostheses (Zweymuller). Z Orthop Grenzgeb 139(3):206–211. doi:10.1055/s-2001-16322
Janda W, Hübl M, Stöckl B et al (2010) Performance of the Zweymüller total hip arthroplasty system: a literature review including arthroplasty register data. Eur Orthop Traumatol 1(1):9–15. doi:10.1007/s12570-010-0004-z
Pospischill M, Knahr K (2005) Cementless total hip arthroplasty using a threaded cup and a rectangular tapered stem. Follow-up for ten to 17 years. J Bone Joint Surg Br Vol 87(9):1210–1215. doi:10.1302/0301-620X.87B9.16107
Pieringer H, Auersperg V, Griessler W, Böhler N (2003) Long-term results with the cementless Alloclassic brand hip arthroplasty system. J Arthroplast 18(3):321–328. doi:10.1054/arth.2003.50045
Grübl A, Chiari C, Giurea A, Gruber M, Kaider A, Marker M, Zehetgruber H, Gottsauner-Wolf F (2006) Cementless total hip arthroplasty with the rectangular titanium Zweymüuller stem. A concise follow-up, at a minimum of fifteen years, of a previous report. J Bone Joint Surg Am 88:2210–2215. doi:10.2106/JBJS.E.00810
Barrack RL, Burnett RSJ (2006) Preoperative planning in revision total hip arthroplasty. Instructional course lecture series. American Academy of Orthopaedic Surgeons. J Bone Joint Surg 87(12):2800–2811
Hernigou P, Queinnec S, Flouzat Lachaniette CH (2013) One hundred and fifty years of history of the Morse taper: from Stephen A. Morse in 1864 to complications related to modularity in hip arthroplasty. Int Orthop 37(10):2081–2088. doi:10.1007/s00264-013-1927-0
Scheuber LF, Usbeck S, Petkow F (2014) Neck taper and compatibility—What does the surgeon have to consider? https://www.ceramtec.com/files/mt_taper_and_compatibility.pdf. Accessed 1 Feb 2014
Kienapfel H, Becker A (2012) Prothesenregister und Langzeitergebnisse. In: Claes L, Kirschner P, Perka C, Herausgeber MR (eds) AE-Manual der Endoprothetik. Springer, Heidelberg, Berlin, pp 419–440
Acknowledgments
The authors would like to thank Luigi Lena (Istituto Ortopedico Rizzoli) for his help with the illustrations, Ms Enza Scifo for her help with the English language, and Ing. Paolo Dalla Pria for his help with technical concepts.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Affatato, S., Comitini, S., Fosco, M. et al. Radiological identification of Zweymüller-type femoral stem prosthesis in revision cases. International Orthopaedics (SICOT) 40, 2261–2269 (2016). https://doi.org/10.1007/s00264-016-3141-3
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00264-016-3141-3