The objective of this study was to compare replacement of the radial head by metal prostheses with open reduction and internal fixation (ORIF) for the treatment of unstable, multi-fragmented radial head fractures. A prospective randomised controlled trial was employed to investigate 45 patients with unstable, multi-fragmented fractures of the radial head, from January 2004 to June 2007. The patients were randomised to two groups: the ORIF group and the radial head replacement group. Over the next two years, follow-up assessments recorded Broberg and Morrey scores and postoperative complication rate. Statistical analysis was performed. According to Broberg and Morrey scores, patients receiving radial head replacement achieved significantly better clinical results with 91% (20/22) good or excellent compared to patients assigned to the ORIF group with 65.2% (15/23) good or excellent results (P < 0.01). Postoperative complication rate of the radial head replacement group (13.6%) was significantly lower than that of the ORIF group (47.9%; P < 0.01). Compared with open reduction and internal fixation, radial head replacement with a metal prostheses resulted in favourable joint function for the unstable, multi-fragmented fractures of the radial head.
Similar content being viewed by others
References
Hall JA, McKee MD (2005) Postero-lateral rotatory instability of the elbow following radial head resection. J Bone Joint Surg Am 87:1571–1579
Lindenhovius AL, Felsch Q, Doornberg JN et al (2007) Open reduction and internal fixation compared with excision for unstable displaced fractures of the radial head. J Hand Surg Am 32(5):630–636
Karlsson MK, Herbertsson P, Nordqvist A et al (2010) Comminuted fractures of the radial head. Acta Orthop 81(2):226–229
Broberg MA, Morrey BF (1986) Results of delayed excision of the radial head after fracture. J Bone Joint Surg Am 68:669–674
Geel C, Palmer A, Ruedi T, Leutenegger A (1990) Internal fixation of proximal radial head fractures. J Orthop Trauma 4:270–274
Geel CW, Palmer AK (1992) Radial head fractures and their effect on the distal radioulnar joint. A rationale for treatment. Clin Orthop Rel Res 275:79–84
Mason ML (1959) Some observations on fractures of the head of the radius with a review of one hundred cases. Br J Surg 42:123–132
Morrey BF (2000) Radial head fracture. In: Merrey BF (ed) The elbow and its disorders, 2nd edn. WB Saunder, Philadelphia, pp 341–364
Dooley JF, Angus PDRS (1991) The importance of elbow aspiration when treating radial head fractures. Arch Emerg Med 8:117–121
Prokop A, Jubel A, Helling HJ et al (2002) New biodegradable polylactide implants (Polypin C) in therapy for radial head fractures. Chirurg 73:997–1004
Lu YP, Xu ST (1991) Orthopaedic surgery. People's Military Medical Press 449
Hotchkiss RN (1998) Fracture of the radial head and related instabilits and contracture of the forearm. Instr Course Lect 47:173–177
Hotchkiss RN (1997) Displaced fractures of the radial head internal fixation or excision? J Am Acad Orthop Surg 5:1–10
Morrey BF, Chao EY, Hui FG (1979) Biomechanical study of the elbow following excision of the radial head. J Bone Joint Surg Am 61:63–68
Ring D, Jupiter JB, Zilberfarb J (2002) Posterior dislocation of the elbow with fractures of the radial head and coronoid. J Bone Joint Surg Am 84:547–551
Josefsson PO, Gentz CF, Johnell O, et al (1989) Dislocations of the elbow and intraarticular fractures. Clin Orthop Relat Res 246:126–130
Geel CW, Palmer AK, Rüedi T, Leutenegger AF (1990) Internal fixation of proximal radial head fractures. J Orthop Trauma 4:270–274
Kelberine F, Basseres B, Curvale G et al (1991) Fractures of the radial head: an analysis of 62 surgically treated cases. Rev Chir Orthop 77:322–328
Pearce MS, Gallannaugh SC (1996) Mason type II radial head fractures fixed with Herbert bone screws. J R Soc Med 89:340–344
Ring D, Quintero J, Jupiter JB (2002) Open reduction and internal fixation of fractures of the radial head. J Bone Joint Surg Am 84:1811–1815
Heim U (1992) Surgical treatment of radial head fracture. Z Unfallchir Versicherungsmed 85:3–11
Cai PH, Mei HG, Fan Yi C et al (2004) Clinical efficacy of internal fixation on Mason type III radial head fractures. Chin J Orthop Trauma 5:496–498
Harrington U, Sekyi-Otu A, Barrington TW et al (2001) The functional outcome with metallic radial head implants in the treatment of unstable elbow fractures: a long-term review. J Trauma 50:46
Grewel R, MacDermid J, Faber K et al (2006) Comminuted radial head fractures treated with a modular metallic radial head arthroplasty: a study of outcomes. J Bone Joint Surg Am 88:2191–2200
Pomianowski S, Morrey BF, Neale PG et al (2001) J Bone Joint Surg Am 83(12):l829–l834
Van Glabbeek F, Van Riet RP, Baumfeld JA et al (2004) Detrimental effects of overstuffing or understuffing with a radial head replacement in the medial collateral-ligament deficient elbow. J Bone Joint Surg Am 86(12):2629
Conflicts of interest
The authors declare they have no conflicts of interest.
Author information
Authors and Affiliations
Corresponding author
Additional information
Xiao Chen and Si-cheng Wang contributed equally to this work.
Rights and permissions
About this article
Cite this article
Chen, X., Wang, Sc., Cao, Lh. et al. Comparison between radial head replacement and open reduction and internal fixation in clinical treatment of unstable, multi-fragmented radial head fractures. International Orthopaedics (SICOT) 35, 1071–1076 (2011). https://doi.org/10.1007/s00264-010-1107-4
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00264-010-1107-4