Upward and inward displacements of the acetabular component increase stress on femoral head in single endoprothesis models

  • Original Article
  • Published:
International Orthopaedics Aims and scope Submit manuscript

Abstract

The centre of rotation of the hip can be displaced in hip dysplasia and revision arthroplasty. This study examined the effect of artificial femoral head load after acetabular component displacement in total hip arthroplasty. Sixteen total hip arthroplasty models of human cadaver specimens were reconstructed, and under different acetabular component position, the load around the femoral head was evaluated by strain gages. The results showed that the load was higher in the same specimens when the cup was moved 2 mm inward or upward, especially after the cup was moved more than 6 mm, and the load had an increasing effect in the inward group. In the upward group, an increasing effect happened at 8 mm upward displacement, but the stress value decreased from 4 mm to 6 mm upward displacement. In the same moving distance, the stress of inward displacement is obviously higher than upward displacement. Altogether, the results suggested that for both inward displacement and upward displacement of the acetabular cup, the load around the femoral head increased gradually, while the distance of the inward displacement and the superior displacement was increased. The greater the displacement, the bigger the loading contact stress. The upward displacement caused less stress change on the femoral head. The stress of the 6 mm upward position was lower than nearby positions; perhaps this site represented a stress buffering zone.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Similar content being viewed by others

References

  1. Udomkiat P, Dorr LD, Wan Z (2002) Cementless hemispheric porous-coated sockets implanted with pressfit technique without screws: average ten-year follow- up. J Bone Joint Surg Am 84:1195–1200

    PubMed  Google Scholar 

  2. Patil S, Bergula A, Chen PC, Colwell CW Jr, D'Lima DD (2003) Polyethylene wear and acetabular component orientation. J Bone Joint Surg Am 85:56–63

    PubMed  Google Scholar 

  3. Wan Z, Boutary M, Dorr LD (2008) The influence of acetabular component position on wear in total hip arthroplasty. J Arthroplasty 23:51–56

    Article  PubMed  Google Scholar 

  4. Witzel U, Rieger W, Effenberger H (2008) Three-dimensional stress analysis of threaded cups—a finite element analysis. Int Orthop 32:195–201

    Article  CAS  PubMed  Google Scholar 

  5. D'Lima DD, Urquhart AG, Buehler KO, Walker RH, Colwell CW Jr (2000) The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios. J Bone Joint Surg Am 82:315–321

    PubMed  Google Scholar 

  6. Widmer KH, Zurfluh B (2004) Compliant positioning of total hip components for optimal range of motion. J Orthop Res 22:815–821

    Article  PubMed  Google Scholar 

  7. Delimar D, Bićanić G, Pećina M, Korzinek K (2004) Acetabular roof reconstruction with pedicled iliac graft: early clinical experience. Int Orthop 28:319–320

    Article  CAS  PubMed  Google Scholar 

  8. Delimar D, Cicak N, Klobucar H, Pećina M, Korzinek K (2002) Acetabular roof reconstruction with pedicled iliac graft. Int Orthop 26:344–348

    Article  PubMed  Google Scholar 

  9. Erceg M (2009) The influence of femoral head shift on hip biomechanics: additional parameters accounted. Int Orthop 33:95–100

    Article  PubMed  Google Scholar 

  10. Delp SL, Wixson RL, Komattu AV, Kocmond JH (1996) How superior placement of the joint center in hip arthroplasty affects the abductor muscles. Clin Orthop Relat Res 328:137–146

    Article  PubMed  Google Scholar 

  11. Gore DR, Murray MP, Gardner GM, Sepic SB (1977) Roentgenographic measurements after Muller total hip replacement: Correlations among roentgenographic measurements and hip strength and mobility. J Bone Joint Surg Am 59:948–953

    CAS  PubMed  Google Scholar 

  12. Bay BK, Hamel AJ, Olson SA, Sharkey NA (1997) Statically equivalent load and support conditions produce different hip joint contact pressures and periacetabular strains. J Biomech 30:193–196

    Article  CAS  PubMed  Google Scholar 

  13. Dearborn JT, Harris WH (1999) High placement of an acetabular component inserted without cement in a revision total hip arthroplasty. Results after a mean of ten years. J Bone Joint Surg Am 81:469–480

    CAS  PubMed  Google Scholar 

  14. Charnley J (1970) Total hip replacement by low-friction arthroplasty. Clin Orthop 72:7–21

    CAS  PubMed  Google Scholar 

  15. Johnston RC, Brand RA, Crowninshield RD (1979) Reconstruction of the hip: A mathematical approach to determine optimum geometric relationships. J Bone Joint Surg Am 61:639–652

    CAS  PubMed  Google Scholar 

  16. Bicanic G, Delimar D, Delimar M, Pecina M (2009) Influence of the acetabular cup position on hip load during arthroplasty in hip dysplasia. Int Orthop 32:397–402

    Article  Google Scholar 

  17. Poss R, Walker P, Spector M, Reilly DT, Robertson DD, Sledge CB (1998) Strategies for improving fixation of femoral components in total hip arthroplasty. Clin Orthop Relat Res 235:181–194

    Google Scholar 

  18. Hirakawa K, Mitsugi N, Koshino T, Saito T, Hirasawa Y, Kubo T (2001) Effect of acetabular cup position and orientation in cemented total hip arthroplasty. Clin Orthop Relat Res 388:135–142

    Article  PubMed  Google Scholar 

  19. Delp SL, Maloney W (1993) Effects of hip center location on the moment-generating capacity of the muscles. J Biomech 26:485–499

    Article  CAS  PubMed  Google Scholar 

  20. Olson SA, Bay BK, Chapman MW, Sharkey NA (1995) Biomechanical consequences of fracture and repair of the posterior wall of the acetabulum. J Bone Joint Surg Am 77:1184–1192

    CAS  PubMed  Google Scholar 

Download references

Acknowledgments

We thank Michael D. Brodt and Daniel J. Wood (Washington University School of Medicine) for critical reading of this paper. We are grateful to Ziji Zhang, Zibo Yang, Zihong Lin, Xing Duan, Yuanchen Ma (Sun Yat-sen University) for their technical assistance in preparation of specimens, and Bo Bai and Nansheng Yu (Guangzhou Medical School) for excellent help in preparing this study.

Conflict of interest statement

This work was supported by China Science and Technology Grant of Guangdong (2007B031002003).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Ming Fu.

Additional information

This study was approved by the Medical Ethical Board of Sun Yat-sen University.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Zhang, Z., Fu, M., Kang, Y. et al. Upward and inward displacements of the acetabular component increase stress on femoral head in single endoprothesis models. International Orthopaedics (SICOT) 34, 479–483 (2010). https://doi.org/10.1007/s00264-009-0788-z

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00264-009-0788-z

Keywords

Navigation