This study examines the association between postoperative coronal tibiofemoral alignment and revision surgery in knee arthroplasty. We retrospectively reviewed the case notes and post-operative long-leg radiographs of 197 Kinemax knee arthroplasty with mean follow-up of 9 years (SD 2.2). They were divided into three groups: neutral, valgus and varus. Revision or decision to revise was used as a hard endpoint. There was no statistical difference among the three groups (p=0.78). We conclude that aseptic failure of a total knee is multifactorial. Coronal tibio-femoral alignment may not be as important a cause of failure as has been previously thought.

Résumé

Cette étude a pour but d’examiner l’alignement des éléments prothétiques dans la chirurgie de reprise de prothèse totale du genou. Nous avons de façon rétrospective revu en 1997 une série de prothèses de type Kinemax avec un suivi moyen de 9 ans (SD 2.2). La population a été divisée en trois groupes : Neutre, Valgus et Varus. Pour les courbes de survie ont été utilisées comme référence la révision ou la décision de révision. Nous pouvons conclure que le descellement aseptique d’une prothèse totale du genou est multi factorielle. L’alignement tibio fémoral n’est pas une cause importante d’échec comme l’on pouvait le penser auparavant.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

References

  1. Bargren JH, Blaha JD, Freeman MAR (1983) Alignment in total knee arthroplasty. Clin Orthop Relat Res 173:178–183

    PubMed  Google Scholar 

  2. Freeman MAR, Todd RC, Bambert P et al (1978) ICLH arthroplsty of the knee: 1968–1977. J Bone Joint Surg 60-B:339–344

    CAS  Google Scholar 

  3. Harvey IA, Manning MP, Sampath SAC et al (1995) Alignment of total knee arthroplasty: the relationship to radiolucency around the tibial component. Med Eng Phys 17:182–187

    Article  PubMed  CAS  Google Scholar 

  4. Hood RW, Vanni M, Insall JN (1981) The correction of knee alignment in 225 consecutive total condylar knee replacement. Clin Orthop 160:94–105

    PubMed  Google Scholar 

  5. Insall JN, Binazzi R, Soudry M et al (1985) Total knee arthroplasty. Clin Orthop Relat Res 192:13–22

    PubMed  Google Scholar 

  6. Insall JN (1984) Total knee replacement. In: Insall JN (ed) Surgery of the knee. Churchill Livingstone, New York

    Google Scholar 

  7. Jeffery RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Joint Surg 73 B:709–714

    Google Scholar 

  8. Knutson K, Lindstrand A, Lindgren L (1986) Survival of knee arthroplasties: a nationwide multicentre investigation of 8000 cases. J Bone Joint Surg 68-B:795–803

    Google Scholar 

  9. Reckling FW, Asher MA, Dillon WL (1977) A longitudinal study of radiolucent line at the bone-cement following total joint replacement procedures. J Bone Joint Surg 59-A:355–358

    Google Scholar 

  10. Ritter MA, Faris PM, Keating EM et al (1994) Postoperative alignment of total knee replacement: its effect on survival. Clin Orthop Relat Res 299:153–156

    PubMed  Google Scholar 

  11. Smith JL Jr, Tullos HS, Davidson JP (1989) Alignment of total knee arthroplasty. J Arhtroplasty 4 Suppl S:55–61

    Article  Google Scholar 

  12. Tew M, Waugh W (1985) Tibiofemoral alignment and the results of knee replacement. J Bone Joint Surge 67-B:551–556

    Google Scholar 

  13. Petersen TL, Engh GA (1988) Radiographic Assessment of Knee Alignment after total knee arthroplasty. J Arthroplasty 31:67–72

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Samer S. Morgan.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Morgan, S.S., Bonshahi, A., Pradhan, N. et al. The influence of postoperative coronal alignment on revision surgery in total knee arthroplasty. International Orthopaedics (SICO 32, 639–642 (2008). https://doi.org/10.1007/s00264-007-0391-0

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00264-007-0391-0

Keywords

Navigation