Skip to main content
Log in

Dynamics of hip joint effusion after posterior soft tissue repair in total hip arthroplasty

  • Original Paper
  • Published:
International Orthopaedics Aims and scope Submit manuscript

Abstract

Dislocation after total hip replacement is more common in the early, postoperative period. Postoperative intraarticular haematoma and remaining seroma fluid and/or weakened posterior soft tissue wall may be contributing factors. Our purpose was to compare and follow with sonography the resorption of the postoperative volume of intraarticular fluid/synovial oedema after total hip arthroplasty (THA) with or without posterior soft tissue repair. Thirty-three consecutive patients with hip osteoarthritis were admitted for THA. All of them received the same type of cemented implant. Patients were randomised for posterior soft tissue repair or not. Sonography, measuring the anterior capsular distension, indicating the volume of intraarticular fluid/synovial oedema in the prosthetic hip joints, was performed after six and 12 months in all patients. At six months postoperatively greater capsular distension, i.e., remaining volume of intraarticular fluid/synovial oedema, was observed in the group with posterior soft tissue repair than in the group without. After one year the capsular distension had decreased in both groups and there was no significant difference between the groups. Our results show that posterior soft tissue repair after THA is associated with increased capsular distension during the first six months. After 12 months the volume of intraarticular fluid/synovial oedema is the same with or without posterior soft tissue repair.

Résumé

La luxation après prothèse totale de la hanche est plus fréquente précocement, en période postopératoire. L’hématome intra-articulaire et /ou l’altération des tissus postérieurs peuvent être des facteurs de cette luxation. Nous avons étudiés par échographie la résorption postopératoire des fluides articulaires et de l’œdème synovial après arthroplastie totale de la hanche faite avec ou sans réparation des tissus postérieurs. 33 patients consécutifs, opérés avec le même type d’implant cimenté furent randomisés vis-à-vis de la réparation, ou non, des tissus postérieurs. L’échographie, mesurant la distension capsulaire antérieure a été faite après 6 et 12 mois chez tous les patients. A 6 mois de l’intervention une augmentation de la distension capsulaire c’est à dire du volume liquidien résiduel était observée dans le groupe avec réparation des tissus postérieurs comparé au groupe sans réparation. Après 1 an la distension décroît dans les deux groupes sans différence significative entre les deux.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

References

  1. Fackler CD, Poss R (1980) Dislocation in total hip arthroplasties. Clin Orthop 151:169–178

    PubMed  Google Scholar 

  2. Földes K, Gaal M, Balint P, Nemenyi K, Kiss C, Balint G, Buchanan W (1992) Ultrasonography after hip arthroplasty. Skeletal Radiol 21(5):297–299

    Article  PubMed  Google Scholar 

  3. Kesteris U, Jonsson K, Robertsson O, Onnerfalt R, Wingstrand H (1999) Polyethylene wear and synovitis in total hip arthroplasty: A sonographic study of 48 hips. J. Arthroplasty 14(2):138–143

    Article  PubMed  CAS  Google Scholar 

  4. McCollum DE, Gray WJ (1990) Dislocation after total hip arthroplasty: causes and prevention. Clin Orthop 261:159–170

    PubMed  Google Scholar 

  5. Mihalko WM, Whiteside LA (2004) Hip mechanics after posterior soft tissue repair in total hip arthroplasty. Clin Orthop Relat Res 420:194–198

    Article  PubMed  Google Scholar 

  6. Pellicci PM, Bostrom M, Poss R (1998) Posterior approach to total hip replacement using enhanced posterior soft tissue repair. Clin Orthop Relat Res 355:224–228

    Article  PubMed  Google Scholar 

  7. Suh KT, Park BG, Choi YJ (2004) A posterior approach to primary total hip arthroplasty with soft tissue repair. Clin Orthop Relat Res 418:162–167

    Article  PubMed  Google Scholar 

  8. van Holsbeeck MT, Eyler WR, Sherman LS, Lombardi TL, Mezger E, Verner JJ, Schurman JR, Jonsson K (1994) Detection of infection in loosened hip prostheses: efficacy of sonography. AJR Am J Roentgenol 163(2):381–384

    PubMed  Google Scholar 

  9. Weeden SH, Paprosky WG, Bowling JW (2003) The early dislocation rate in primary total hip arthroplasty following the posterior approach with posterior soft-tissue repair. J Arthroplasty 18(6):709–713

    Article  PubMed  Google Scholar 

  10. Wingstrand H, Egund N, Nilsson L T, Strömqvist B (1998) Acetabular fracture causing hip joint tamponade. Acta Orthop Scand 59(3):323–325

    Google Scholar 

  11. Wingstrand H, Strömqvist B, Egund N, Gustafson T, Nilsson LT, Thorngren KG (1986) Hemarthrosis in undisplaced cervical fractures. Tamponade may cause reversible femoral head ischemia. Acta Orthop Scand 57(4):305–308

    Article  PubMed  CAS  Google Scholar 

  12. Wingstrand H, Wingstrand A (1997) Biomechanics of the hip joint capsule—a mathematical model and clinical implications. Clin Biomech 22(5):273–280

    Article  Google Scholar 

Download references

Acknowledgement

This study was supported by the Pfizer EU ARTICULUM Fellowship.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Sarunas Tarasevicius.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Tarasevicius, S., Kesteris, U., Kalesinskas, R.J. et al. Dynamics of hip joint effusion after posterior soft tissue repair in total hip arthroplasty. International Orthopaedics (SICO 30, 233–236 (2006). https://doi.org/10.1007/s00264-005-0064-9

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00264-005-0064-9

Keywords

Navigation