Hepatic CT enhancement: effect of the rate and volume of contrast medium injection in an animal model

  • Published:
Abdominal Imaging Aims and scope Submit manuscript

Abstract

Background: To evaluate the relative effect of rate of injection and volume of contrast medium on aortic, portal, and hepatic enhancement during computed tomography (CT).

Methods: Thirty-eight nonincremental CT examinations were performed in three mini-pigs by using a combination of three different volumes (1.5, 2, and 3 mL/kg) and five different rates (1.5, 3, 4.5, 6, and 7.5 mL/s) of contrast material injection. Time-density enhancement curves of the aorta, portal vein, and liver were plotted over time for each rate of injection, each volume of contrast, and each volume–rate combination. In addition, aortic, portal, and liver peak enhancements, time-to-peak enhancements, optimal scanning intervals, and contrast enhancement indices were calculated for each volume–rate combination.

Results: Higher rates of injection increased peak aortic enhancement but had no effect on peak portal or hepatic enhancement. This result may be explained by the dilution of the bolus of contrast medium in the splanchnic circulation. When the results of a 6-mL/s injection of 1.5 mL/kg of contrast material were compared with a 3-mL/s injection of 2 mL/kg, maximum aortic enhancement increased by 32%, whereas maximum liver enhancement decreased by 35%.

Conclusion: An increase in the rate of contrast injection results in an increase of peak aortic enhancement even when the total iodine load is decreased. However, an increase of the rate of contrast injection does not increase maximum liver enhancement, which is related to the total iodine dose injected. Therefore, one cannot compensate a decrease in the iodine load by an increase in injection rate in contrast-enhanced CT of the liver.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received: 3 September 1997/Revision accepted: 13 January 1999

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Garcia, P., Genin, G., Bret, P. et al. Hepatic CT enhancement: effect of the rate and volume of contrast medium injection in an animal model. Abdom Imaging 24, 597–603 (1999). https://doi.org/10.1007/s002619900572

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s002619900572

Navigation