Elastic surface contour detection for the measurement of ejection fraction in myocardial perfusion SPET

  • Original Article
  • Published:
European Journal of Nuclear Medicine Aims and scope Submit manuscript

Abstract.

The aim of this study was to investigate the use of an automated three-dimensional myocardial contour detection method using elastic surfaces for the assessment of left ventricular ejection fraction (EF) from electrocardiographically (ECG) triggered myocardial perfusion single-photon emission tomography (SPET). The validity of this method was studied on the basis of both phantom measurements and patient studies. Phantom measurements were performed using an elastic phantom of the left ventricle simulating a beating heart, with a simulated EF ranging from 10% to 78%. The data from 27 patients who had undergone both ECG-triggered myocardial perfusion SPET and planar gated radionuclide ventriculography (RNV) were used to compare the EF derived from the SPET data with the automated contour detection method and the EF derived from the RNV data with standard analysis software. EF values as measured by RNV ranged from 11% to 68%. The overall accuracy of the automated contour detection method proved to be very high. In the phantom study the deviation of the measured EF from the reference values was less than 4% for all of the simulated EFs. The studies on the patient data yielded a correlation coefficient (Pearson) greater than 0.94 as compared with planar RNV. Intra- and inter-observer reproducibility was high, with correlation coefficients exceeding 0.97. It is concluded that the proposed method allows accurate, reproducible and fast measurement of the left ventricular EF on the basis of myocardial perfusion SPET.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received 24 June and in revised form 10 September 2000

Electronic Publication

Rights and permissions

Reprints and permissions

About this article

Cite this article

Stegger, L., Biedenstein, S., Schäfers, K. et al. Elastic surface contour detection for the measurement of ejection fraction in myocardial perfusion SPET. Eur J Nucl Med 28, 48–55 (2001). https://doi.org/10.1007/s002590000391

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s002590000391

Navigation