Dual-modality PET/CT imaging: the effect of respiratory motion on combined image quality in clinical oncology

  • Original Article
  • Published:
European Journal of Nuclear Medicine and Molecular Imaging Aims and scope Submit manuscript

Abstract

To reduce potential mis-registration from differences in the breathing pattern between two complementary PET and CT data sets, patients are generally allowed to breathe quietly during a dual-modality scan using a combined PET/CT tomograph. Frequently, however, local mis-registration between the CT and the PET is observed. We have evaluated the appearance, magnitude, and frequency of respiration-induced artefacts in CT images of dual-modality PET/CT studies of 62 patients. Combined PET/CT scans during normal respiration were acquired in 43 subjects using single- or dual-slice CT. Nineteen patients were scanned with a special breathing protocol (limited breath-hold technique) on a single-slice PET/CT tomograph. All subjects were injected with ~370 MBq of FDG, and PET/CT scanning commenced 1 h post injection. The CT images were reconstructed and, after appropriate scaling, used for on-line attenuation correction of the PET emission data. We found that respiration artefacts can occur in the majority of cases if no respiration protocol is used. When applying the limited breath-hold technique, the frequency of severe artefacts in the area of the diaphragm was reduced by half, and the spatial extent of respiration-induced artefacts was reduced by at least 40% compared with the acquisition protocols without any breathing instructions. In conclusion, special breathing protocols are effective and should be used for CT scans as part of combined imaging protocols using a dual-modality PET/CT tomograph. The results of this study can also be applied to multi-slice CT to potentially reduce further breathing artefacts in PET/CT imaging and to improve overall image quality.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1a–c.
Fig. 2a–c.
Fig. 3a–e.
Fig. 4a–e.
Fig. 5a–e.
Fig. 6.
Fig. 7a, b.
Fig. 8.
Fig. 9a–c.

Similar content being viewed by others

References

  1. Gambhir SS, Czernin J, Schwimmer J, Silverman DHS, Coleman EE, Phelps ME. A tabulated summary of the FDG PET literature. J Nucl Med 2001; 42 (5 Suppl):1S–93S.

    Google Scholar 

  2. Vansteenkiste JF, Stroobants SG, Dupont PJ, Leyn PRD, Wever WF, Verbeken EK, Nuyts JL, Maes FP, Bogaert JG. FDG-PET scan in potentially operable non-small cell lung cancer: Do anatometabolic PET-CT fusion images improve the localisation of regional lymph node metastasis? Eur J Nucl Med 1998; 25:1495–1501.

    Google Scholar 

  3. Hutton BF, Braun M, Thurfjell L, Lau DYH. Image registration: an essential tool for nuclear medicine. Eur J Nucl Med 2002; 29:559–577.

    Google Scholar 

  4. Woods RP, Grafton ST, Holmes CJ, Cherry SR, Mazziotta JC. Automated image registration. I. General methods and intrasubject, intramodality validation. J Comput Assist Tomogr 1998; 22:139–152.

    Google Scholar 

  5. Yu JN, Fahey FH, Gage HD, Eades CG, Harkness BA, Pelizzari CA, Keys JW Jr. Intermodality, retrospective image registration in the thorax. J Nucl Med 1995; 36:2333–2338.

    Google Scholar 

  6. Townsend DW, Cherry S. Combining anatomy and function: the path to true image fusion. Eur Radiol 2001; 11:1968–1974.

    Google Scholar 

  7. Beyer T, Townsend DW, Brun T, Kinahan PE, Charron M, Roddy R, Jerin J, Young J, Nutt R, Byars LG. A combined PET/CT tomograph for clinical oncology. J Nucl Med 2000; 41:1369–1379.

    Google Scholar 

  8. Kinahan PE, Townsend DW, Beyer T, Sashin D. Attenuation correction for a combined 3D PET/CT scanner. Med Phys 1998; 25:2046–2053.

    Google Scholar 

  9. von Schulthess GK. Cost considerations regarding an integrated CT-PET system. Eur Radiol 2000; 10 (Suppl 3):S377–S380.

    Google Scholar 

  10. Hoh CK, Hawkins RA, Glaspy JA, Dahlbom M, Tse NY, Hoffman EJ, Schiepers C, Choi Y, Rege S, Nitzsche E, Maddahi J, Phelps ME. Cancer detection with whole-body PET using 2-[18F]fluoro-2-deoxy-d-glucose. J Comput Assist Tomogr 1993; 17:582–589.

    Google Scholar 

  11. Beyer T, Townsend D, Blodgett T. Dual-modality PET/CT tomography for clinical oncology. Q J Nucl Med 2002; 46:24–34.

    Google Scholar 

  12. Goerres GW, Kamel E, Heidelberg T-NH, Schwitter MR, Burger C, von Schulthess GK. PET-CT image co-registration in the thorax: influence of respiration. Eur J Nucl Med 2002; 29:351–360.

    Google Scholar 

  13. Beyer T, Townsend D. Dual-modality PET/CT imaging: CT-based attenuation correction in the presence of CT contrast agents. J Nucl Med 2001; 42:56P.

    Google Scholar 

  14. Carney J, Beyer T, Brasse D, Yap J, Townsend D. Clinical PET/CT scanning using oral CT contrast agents. J Nucl Med 2002; 43:57P.

    Google Scholar 

  15. Meikle SR, Dahlbom M, Cherry SR. Attenuation correction using count-limited transmission data in positron emission tomography. J Nucl Med 1993; 34:143–150.

    Google Scholar 

  16. Cohade C, Osman M, Wahl RL. Accuracy of PET and CT spatial registration of lung lesions with PET-CT. J Nucl Med 2002; 43:14P–15P.

    Google Scholar 

  17. Nakamoto Y, Cohade C, Osman M, Tatsumi M, Traughber BJ, Marshall LT, Wahl RL. Comparison of size and location of normal upper abdominal organs on PET and CT using PET/CT. J Nucl Med 2002; 43:14P.

    Google Scholar 

  18. Osman MM, Cohade C, Nakamoto Y, Wahl RL. Clinically significant inaccurate localization of lesions with PET-CT: frequency in 275 patients. J Nucl Med 2002; 43:32P.

    Google Scholar 

Download references

Acknowledgements

The authors like to thank Paulina Khersonskaya, Sam Hsiao, Bärbel Terschüren, Sandra Pabst, and Ruth Hall for their help with the data acquisition. This paper benefited from helpful discussions with David Townsend, Jeffrey Yap, and Thomas Bruckbauer.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Thomas Beyer.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Beyer, T., Antoch, G., Blodgett, T. et al. Dual-modality PET/CT imaging: the effect of respiratory motion on combined image quality in clinical oncology. Eur J Nucl Med Mol Imaging 30, 588–596 (2003). https://doi.org/10.1007/s00259-002-1097-6

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00259-002-1097-6

Keywords

Navigation