Abstract

Objective

To compare MR images of the triangular fibrocartilage complex (TFCC) using microscopy coils with those using a conventional surface coil qualitatively and quantitatively.

Design and patients

Proton density-weighted images and T2*-weighted images of the TFCC from ten normal volunteers were obtained with a conventional surface coil (C4 coil; 80 mm in diameter), a 47-mm microscopy surface coil and a 23-mm microscopy surface coil) at 1.5 T. Qualitative image analysis of MR images with three coils was performed by two radiologists who assigned one of five numerical scores (0, nonvisualization; 1, poor; 2, average; 3, good; 4, excellent) for five TFCC components, which were disc proper, triangular ligament, meniscus homologue, ulnotriquetral and ulnolunate ligament. Quantitative analysis included the signal-to-noise ratio (S/N) of the disc proper of TFCC, the lunate cartilage, the lunate bone and the contrast-noise-ratio (C/N) between articular cartilage and disc proper or bone marrow were measured.

Results

All structures show higher scores qualitatively on MR with microscopy coils than those with a C4 coil, and the difference was significant with the exception of the ulnolunate ligament. MR with microscopy coils showed significantly higher S/N values than those with a conventional surface coil (P<0.05 to P<0.001). T2*-weighted images using microscopy coils showed significantly higher cartilage-disc proper C/N and cartilage-bone marrow C/N (P<0.01 to P<0.001). On proton density-weighted images, the C/N between cartilage and disc proper with two microscopy coils was significantly higher (P<0.01) than that with a conventional coil.

Conclusion

High-resolution MR images of the normal wrist using microscopy coils were superior to those using a conventional surface coil qualitatively and quantitatively. High-resolution MR imaging with a microscopy coil would be a promising method to diagnose TFCC lesions.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1.
Fig. 2.
Fig. 3.
Fig. 4.
Fig. 5.
Fig. 6.

Similar content being viewed by others

References

  1. Timins ME, O'Connell SE, Erickson SJ, Oneson SR (1996) MR imaging of the wrist: normal findings that may simulate disease. Radiographics 16:987–995

  2. Totterman SMS, Miller R, Wasserman B, Blebea JS, Rubens DJ (1993) Intrinsic and extrinsic carpal ligaments: evaluation by three-dimensional Fourier transform MR imaging. AJR 160:117–123

  3. Horton MG, Timins ME (1997) MR imaging of injuries to small joints. Radiol Clin North Am 3:671–700

  4. Imaeda T, Nakamura R, Shinoyama K, Makino N (1996) Ulnar impaction syndrome: MR imaging findings. Radiology 201:495–500

  5. Ashman CJ, Farooki S, Abduljalil AM, Chakeres DW (2002) In vivo high-resolution coronal MRI of the wrist at 8.0 T. J Comput Assist Tomogr 26:387–391

  6. Lewis AR, Noran MJ, Hodgson RJ et al (1996) High-resolution magnetic resonance imaging of the proximal interphalangeal joints. Correlation with histology and production of a three-dimensional data set. J Hand Surg Br 21:288–495

  7. Nakamura T, Makita A (2000) The proximal ligamentous component of the triangular fibrocartilage complex. Functional anatomy and three-dimensional changes in length of the radioulnar ligament during pronation and supination. J Hand Surg Br 25:479–486

  8. Totterman SMS, Miller RJ (1995) Triangular fibrocartilage complex: normal appearance on coronal three-dimensional gradient-recalled-echo MR images. Radiology 195:521–527

  9. Totterman SMS, Miller RJ, McCance SE, Meyers SP (1996) Lesions of the triangular fibrocartilage complex: MR findings with a three-dimensional gradient-recalled-echo sequence. Radiology 199:227–232

  10. Oneson SR, Timins ME, Scales LM, Erickson SJ, Chamoy L (1997) MR imaging diagnosis of triangular fibrocartilage pathology with arthroscopic correlation. AJR 168:1513–1518

  11. Potter HG, Anis-Ernberg L, Weiland AJ, Hotchkiss RN, Peterson MGE, McCormack RR Jr (1997) The utility of high-resolution magnetic resonance imaging in the evaluation of the triangular fibrocartilage complex of the wrist. J Bone Joint Surg Am 79:1675–1684

  12. Schweitzer ME, Brahme SK, Holdler J, et al (1992) Chronic wrist pain: spin-echo and short tau inversion recovery MR imaging and conventional and MR arthrography. Radiology 182:205–211

  13. Oneson SR, Scales LM, Timins ME, Erickson SJ, Chamoy L (1996) MR imaging interpretation of the Palmer classification of triangular fibrocartilage complex lesions. Radiographics 16:97–106

  14. Morley J, Bidwell J, Bransby-Zachary M (2001) A comparison of the findings of wrist arthroscopy and magnetic resonance imaging in the investigation of wrist pain. J Hand Surg Br 26:544–546

  15. Haims AH, Schweitzer ME, Morrison WB, et al (2002) Limitations of MR imaging in the diagnosis of peripheral tears of the triangular fibrocartilage of the wrist. AJR 178:419–422

  16. Kato H, Nakamura R, Shionoya K, Makino N, Imaeda T (2000) Does high-resolution MR imaging have better accuracy than standard MR imaging for evaluation of the triangular fibrocartilage complex? J Hand Surg Br 25:487–491

  17. Shinoyama K, Nakamura R, Imaeda T, Makino N (1998) Arthrography is superior to magnetic resonance imaging for diagnosing injuries of the triangular fibrocartilage. J Hand Surg Br 23:402-405

  18. Johnstone DJ, Thorogood S, Smith WH, Scott TD (1997) A comparison of magnetic resonance imaging and arthroscopy in the investigation of chronic wrist pain. J Hand Surg Br 22:714–718

  19. Nakamura T, Yabe Y, Horiuchi Y, Takayama S, Makita A (1998) Dynamic changes of the triangular fibrocartilage complex during rotation—an experimental study using high-resolution MRI. J Jpn Soc Surg Hand 14:907–912

  20. Yoshioka H, Kujiraoka Y, Ueno T, Tanaka T, Mishima H, Itai Y (2002) High-resolution MR imaging of the hand and wrist using a microscopy surface coil at clinical 1.5 T MR machine. Radiology [Suppl] 225:734

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Hiroshi Yoshioka.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Yoshioka, H., Ueno, T., Tanaka, T. et al. High-resolution MR imaging of triangular fibrocartilage complex (TFCC): comparison of microscopy coils and a conventional small surface coil. Skeletal Radiol 32, 575–581 (2003). https://doi.org/10.1007/s00256-003-0672-7

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00256-003-0672-7

Keywords

Navigation