Skip to main content
Log in

Recovery of GFP-Labeled Bacteria for Culturing and Molecular Analysis after Cell Sorting Using a Benchtop Flow Cytometer

  • Published:
Microbial Ecology Aims and scope Submit manuscript

Abstract

Exciting opportunities exist for the application of simple fluorescence-activated cell sorting (FACS) to microbiology. The technology is widely available, but critical reports on the efficiency of cell sorting using benchtop instruments are lacking. It is vital that single cell sorting be of the highest purity possible. If purity is compromised detrital material or unwanted cells will be captured along with target cells of interest. Here, the isolation of fluorescent bacteria using a benchtop FACSCalibur-sort flow cytometer is described. The efficiency and purity of isolated cells was determined using fluorescence microscopy, culturing, and molecular analysis. To achieve high purity it was essential that the total event rate did not exceed 300 cells per second. This instrument was capable of recovering >55% sorted Escherichia coli cells, coupled with a purity exceeding 99%. However, the purity of recovered cells was substantially reduced (<25%) when the event rate increased. Cell sorting onto polycarbonate membranes did not reduce the ability of E. coli to form colonies, and sorting of ~1000 E. coli cells was sufficient for 16S rDNA amplification. Additionally, as few as 100 isolated Erwinia sp. carrying the gfp gene were amplified using seminested PCR targeting the single copy gfp gene. With such low numbers of bacteria being required for molecular identification, FACS can be achieved without the requirement for high-speed droplet cell sorters.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Figure 1
Figure 2

Similar content being viewed by others

References

  1. L Bernard C Courties C Dupperray H Schafer G Muyzer (2001) ArticleTitleA new approach to determine the genetic diversity of viable and active bacteria in aquatic ecosystems. Cytometry 43 314 Occurrence Handle10.1002/1097-0320(20010401)43:4<314::AID-CYTO1064>3.3.CO;2-8 Occurrence Handle1:STN:280:DC%2BD3M7mtFKhsg%3D%3D Occurrence Handle11260599

    Article  CAS  PubMed  Google Scholar 

  2. BC Ferrari G Vesey KA Davis M Gauci D Veal (2000) ArticleTitleA novel two-color flow cytometric assay for the detection of Cryptosporidium in environmental water samples. Cytometry 41 216–222

    Google Scholar 

  3. B Ferrari P Attfield D Veal P Bell (2003) ArticleTitleApplication of a novel fluorescent dye Beljian red to the differentiation of Giardia cysts. J Microbiol Methods 52 133 Occurrence Handle10.1016/S0167-7012(02)00130-6 Occurrence Handle1:CAS:528:DC%2BD38XotVKru7s%3D Occurrence Handle12401235

    Article  CAS  PubMed  Google Scholar 

  4. J Gasol U Zweifel F Peters J Fuhrman A Hagstrom (1999) ArticleTitleSignificance of size and nucleic acid content heterogeneity as measured by flow cytometry in natural planktonic bacteria. Appl Environ Microbiol 65 4475 Occurrence Handle1:CAS:528:DyaK1MXms1Oisbo%3D Occurrence Handle10508078

    CAS  PubMed  Google Scholar 

  5. T Gunasekera D Veal P Attfield (2002) ArticleTitlePotential for broad applications of flow cytometry and fluorescence techniques in microbiological and somatic cell analyses of milk. Int J Food Microbiol 2673 1

    Google Scholar 

  6. LH Hansen B Ferrari AH Sorensen D Veal SJ Sorensen (2001) ArticleTitleDetection of oxytetracycline production by Streptomyces rimosus in soil microcosms by combining whole-cell biosensors and flow cytometry. Appl Environ Microbiol 67 239 Occurrence Handle10.1128/AEM.67.1.239-244.2001 Occurrence Handle1:CAS:528:DC%2BD3MXjtVWnsQ%3D%3D Occurrence Handle11133451

    Article  CAS  PubMed  Google Scholar 

  7. F Joux P Lebaron (2000) ArticleTitleUse of fluorescent probes to assess physiological functions of bacteria at single-cell level. Microbes Infect 2 1523 Occurrence Handle10.1016/S1286-4579(00)01307-1 Occurrence Handle1:STN:280:DC%2BD3M7ivVersA%3D%3D Occurrence Handle11099939

    Article  CAS  PubMed  Google Scholar 

  8. J Klappenbach P Saxman J Cole T Schmidt (2001) ArticleTitleRRNDB: the ribosomal RNA operon copy number database. Nucleic Acids Res 29 181 Occurrence Handle10.1093/nar/29.1.181 Occurrence Handle1:CAS:528:DC%2BD3MXjtlWms7g%3D Occurrence Handle11125085

    Article  CAS  PubMed  Google Scholar 

  9. P Lebaron P Servais H Agogue C Courties F Joux (2001) ArticleTitleDoes the high nucleic acid content of individual bacterial cells allow us to discriminate between active cells and inactive cells in aquatic systems? Appl Environ Microbiol 67 1775 Occurrence Handle10.1128/AEM.67.4.1775-1782.2001 Occurrence Handle1:CAS:528:DC%2BD3MXis1egtLo%3D Occurrence Handle11282632

    Article  CAS  PubMed  Google Scholar 

  10. J Porter C Edwards JAW Morgan RW Pickup (1993) ArticleTitleRapid, automated separation of specific bacteria from lake water and sewage by flow cytometry and cell sorting. Appl Environ Microbiol 59 3327 Occurrence Handle1:STN:280:ByuD2s7ksVc%3D Occurrence Handle8250557

    CAS  PubMed  Google Scholar 

  11. M Power SR Shanker NC Sangster D Veal (2003) ArticleTitleEvaluation of a combined immunomagnetic separation/flow cytometry technique for epidemiological investigations of Cryptosporidium in domestic and Australian native animals. Vet Parasitol 112 21 Occurrence Handle10.1016/S0304-4017(02)00414-4 Occurrence Handle1:STN:280:DC%2BD3s%2Fnt1entA%3D%3D Occurrence Handle12581582

    Article  CAS  PubMed  Google Scholar 

  12. HM Shapiro (1995) Practical Flow Cytometry AR Liss New York

    Google Scholar 

  13. T Silhavy M Berman L Enquist (1984) Experiments with Gene Fusions Cold Spring Harbour Laboratory Press Cold Spring Harbor, NY

    Google Scholar 

  14. Y Tanaka N Yamaguchi M Nasu (2000) ArticleTitleViability of Escherichia coli O157:H7 in natural river water determined by the use of flow cytometry. J Appl Microbiol 88 228 Occurrence Handle10.1046/j.1365-2672.2000.00960.x Occurrence Handle1:STN:280:DC%2BD3c3gtVyjtw%3D%3D Occurrence Handle10735990

    Article  CAS  PubMed  Google Scholar 

  15. DA Veal D Deere B Ferrari J Piper PV Attfield (2000) ArticleTitleFluorescent staining and flow cytometry for monitoring microbial cells. J Immunol Methods 243 191 Occurrence Handle10.1016/S0022-1759(00)00234-9 Occurrence Handle1:CAS:528:DC%2BD3cXmtlGlu7Y%3D Occurrence Handle10986415

    Article  CAS  PubMed  Google Scholar 

  16. G Wallner B Fuchs S Spring W Beisker R Amann (1997) ArticleTitleFlow sorting of microorganism for molecular analysis. Appl Environ Microbiol 63 4223 Occurrence Handle1:CAS:528:DyaK2sXnt12nsbg%3D Occurrence Handle9361408

    CAS  PubMed  Google Scholar 

  17. W Weisburg S Barns D Pelletier D Lane (1991) ArticleTitle16S ribosomal DNA amplification for phylogenetic study. J Bacteriol 173 697 Occurrence Handle1:CAS:528:DyaK3MXhsl2lurY%3D Occurrence Handle1987160

    CAS  PubMed  Google Scholar 

  18. C Yeates MR Gillings (1998) ArticleTitleRapid purification of DNA from soil for molecular biodiversity analysis. Lett Appl Microbiol 27 49 Occurrence Handle10.1046/j.1472-765X.1998.00383.x Occurrence Handle1:CAS:528:DyaK1cXlslWrsro%3D

    Article  CAS  Google Scholar 

Download references

Acknowledgments

This work was funded through an Australian Research Council Linkage International Award (LX0347172) and a postdoctoral grant, “Whole Cell Biosensors Applied in Microbiology,” through the Danish Natural Research council (21-02-0154). Gunnar Oregaard was supported by the Danish Ministry of Food, Agriculture and Fisheries, projects BIOT99-KU-11. Thanks to Michael Gillings and Marita Holley for technical advice on 16S PCR.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to B.C. Ferrari.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Ferrari, B., Oregaard, G. & Sørensen, S. Recovery of GFP-Labeled Bacteria for Culturing and Molecular Analysis after Cell Sorting Using a Benchtop Flow Cytometer. Microb Ecol 48, 239–245 (2004). https://doi.org/10.1007/s00248-003-1069-9

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00248-003-1069-9

Keywords

Navigation