Abstract
Localization of the source of gastrointestinal hemorrhage can be challenging. Currently, this is often accomplished with tagged red blood cell scintigraphy, with attendant ionizing radiation and relatively poor spatial resolution. We describe an analogous method of detecting acute gastrointestinal hemorrhage by enhanced MRI with blood pool contrast agent. Briefly, following precontrast fat-suppressed volumetric T1-weighted image acquisition, single-dose gadofosveset trisodium, a blood pool agent, is administered. Then serial post-T1-weighted images are obtained. This technique is a novel method for evaluating gastrointestinal hemorrhage.
Similar content being viewed by others
References
Kennedy DW, Laing CJ, Tseng LH et al (2010) Detection of active gastrointestinal hemorrhage with CT angiography: a 4(1/2)-year retrospective review. J Vasc Interv Radiol 21:848–855
Garcia-Tsao G, Bosch J (2010) Management of varices and variceal hemorrhage in cirrhosis. N Engl J Med 362:823–832
Currie GM, Kiat H, Wheat JM (2010) Scintigraphic evaluation of acute lower gastrointestinal hemorrhage: current status and future directions. J Clin Gastroenterol 45:92–99
Marcos HB, Noone TC, Semelka RC (1998) MRI evaluation of acute renal trauma. J Magn Reson Imaging 8:989–990
Hasegawa SL, Eisenberg B, Semelka RC (1998) Active intrahepatic gadolinium extravasation following TIPS. Magn Reson Imaging 16:851–853
Lauffer RB, Parmelee DJ, Ouellet HS et al (1996) MS-325: a small-molecule vascular imaging agent for magnetic resonance imaging. Acad Radiol 3(Suppl 2):S356–S358
Cornelissen SA, Prokop M (2010) Detection of occult endoleaks after endovascular treatment of abdominal aortic aneurysm using magnetic resonance imaging with a blood pool contrast agent: preliminary observations. Invest Radiol 45:548–53
Lauffer RB, Parmelee DJ, Dunham SU et al (1998) MS-325: albumin-targeted contrast agent for MR angiography. Radiology 207:529–538
Caravan P, Parigi G, Chasse JM et al (2007) Albumin binding, relaxivity, and water exchange kinetics of the diastereoisomers of MS-325, a gadolinium(III)-based magnetic resonance angiography contrast agent. Inorg Chem 46:6632–6639
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Williams, J., Vasanawala, S.S. Active gastrointestinal hemorrhage identification by blood pool contrast-enhanced magnetic resonance angiography. Pediatr Radiol 41, 1198–1200 (2011). https://doi.org/10.1007/s00247-011-2139-7
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00247-011-2139-7