MRI-based blood oxygen saturation measurements in infants and children with congenital heart disease

  • Original Article
  • Published:
Pediatric Radiology Aims and scope Submit manuscript

Abstract

Background: Vessel oxygen saturation can be determined with MR oximetry using an in vivo measurement of signal decay (T2) and the calibration curve relating T2 to blood oxygen saturation (%HbO2), where: 1/T2=1/T2O+K (1–%HbO2/100)2 and K is a constant parameter which correlates with measured fibrinogen levels. The ability to noninvasively measure %HbO2 in cardiac chambers and vessels has enormous potential in children with congenital heart disease (CHD). Objective: The purpose of the study was to prospectively characterize the T2–%HbO2 relationship in infants where T2–%HbO2 is the realtionship between T2 and %HbO2 (blood oxygen saturation) expressed by the equation given above, and to determine whether adult values for K and T2O (where T2O is the T2 of fully oxygenated blood) can be extrapolated to pediatric patients with CHD. A second objective was to apply this method to calculate the %HbO2 in vivo using MR imaging in infants with CHD. Materials and methods: Fifteen patients with CHD undergoing cardiac catheterization (9 male; 6 female), median age 8 months, were recruited for the calibration study. T2O and K were measured directly from blood samples, compared with the values estimated from adult population statistics, and plotted against hematocrit and fibrinogen, respectively. In four studies of infants with CHD, T2 measurements were converted to %HbO2 using the calibration curve. Results: The T2–%HbO2 relationship in infants correlated with the adult calibration statistics (1/T2O vs. hematocrit, r=0.77; K vs. fibrinogen, r=0.61). Our initial in vivo studies demonstrated that the MR oximetry reflected the expected oxygen saturations. Conclusion: Adult values for T2–%HbO2 calibration can be used to measure blood oxygen saturation in vivo in children with CHD.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Electronic Publication

Rights and permissions

Reprints and permissions

About this article

Cite this article

Nield, L.E., Qi, X., Yoo, SJ. et al. MRI-based blood oxygen saturation measurements in infants and children with congenital heart disease. Ped Radiol 32, 518–522 (2002). https://doi.org/10.1007/s00247-001-0652-9

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00247-001-0652-9

Navigation