Abstract

Introduction

Coiling associated with placement of self-expandable intracranial stents has amplified the treatment of intracranial wide-necked aneurysms, but the durability of this treatment and the existence of delayed recurrence are not yet well known. The purpose of this report is to present our experience with the Neuroform Stent associated with coiling and to evaluate complications, effectiveness, and long-term results of this technique.

Methods

A retrospective study of 42 patients with wide-necked cerebral aneurysms treated with the Neuroform Stent was performed. Mean aneurysm size was 11.3 mm. Mean neck size was 5.33 mm. All patients were treated with coiling and stenting. Clinical and angiographic follow-up was available in 38 patients (90.5%). The overall follow-up time ranged from 6 months to 5 years (mean, 42 months), but most of the patients (92%) had a follow-up period superior to 1 year.

Results

Successful deployment of 41 stents (97%) was obtained. Permanent procedural morbidity was observed in only one patient (2.4%). Long-term complete aneurysmal occlusion was obtained in 27 patients (71%). Aneurysmal regrowth was observed in four patients (9.5%) on the first control angiogram. After the first control angiogram, no delayed recanalization or regrowth was observed. During the follow-up period, there were no hemorrhagic events, no delayed thrombosis, and no stent displacement.

Conclusion

Our results demonstrate the effectiveness of the technique, a small rate of procedural complications, and long-term tolerance of the Neuroform Stent. Despite some evidence of early aneurysmal recurrence, long-term durability of stent-assisted aneurysm occlusion is stable after the first year.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Molyneux A, Kerr R, Stratton I et al (2002) International Subarachnoid Aneurysm Trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised trial. Lancet 360:1267–1274. doi:10.1016/S0140-6736(02)11314-6

    Article  PubMed  Google Scholar 

  2. Murayama Y, Nien YL, Duckwiler G et al (2003) Guglielmi detachable coil embolization of cerebral aneurysms: 11 years’ experience. J Neurosurg 98:959–966

    PubMed  Google Scholar 

  3. Brilstra EH, Rinkel GJ, van der Graaf Y et al (1999) Treatment of intracranial aneurysms by embolization with coils: a systematic review. Stroke 30:470–476

    PubMed  CAS  Google Scholar 

  4. Cloft HJ, Joseph GJ, Tong FC et al (2000) Use of three-dimensional Guglielmi detachable coils in the treatment of wide-necked cerebral aneurysms. AJNR Am J Neuroradiol 21:1312–1314

    PubMed  CAS  Google Scholar 

  5. Malek AM, Higashida RT, Phatouros CC et al (1999) Treatment of an intracranial aneurysm using a new three-dimensional-shape Guglielmi detachable coil: technical case report. Neurosurgery 44:1142–1144 (discussion 1144–1145). doi:10.1097/00006123-199905000-00125

    Article  PubMed  CAS  Google Scholar 

  6. Moret J, Cognard C, Weill A et al (1997) Reconstruction technique in the treatment of wide-neck intracranial aneurysms. Long-term angiographic and clinical results. Apropos of 56 cases. J Neuroradiol 24:30–44

    PubMed  CAS  Google Scholar 

  7. Alfke K, Straube T, Dorner L et al (2004) Treatment of intracranial broad-neck aneurysms with a new self-expanding stent and coil embolization. AJNR Am J Neuroradiol 25:584–591

    PubMed  Google Scholar 

  8. Benitez RP, Silva MT, Klem J et al (2004) Endovascular occlusion of wide-necked aneurysms with a new intracranial microstent (Neuroform) and detachable coils. Neurosurgery 54:1359–1367 (discussion 1368). doi:10.1227/01.NEU.0000124484.87635.CD

    Article  PubMed  Google Scholar 

  9. Broadbent LP, Moran CJ, Cross DT et al (2003) Management of neuroform stent dislodgement and misplacement. AJNR Am J Neuroradiol 24:1819–1822

    PubMed  Google Scholar 

  10. Fiorella D, Albuquerque FC, Han P et al (2004) Preliminary experience using the Neuroform stent for the treatment of cerebral aneurysms. Neurosurgery 54:6–16 (discussion 16–17). doi:10.1227/01.NEU.0000097194.35781.EA

    Article  PubMed  Google Scholar 

  11. Fiorella D, Albuquerque FC, Deshmukh VR et al (2006) Endovascular reconstruction with the Neuroform stent as monotherapy for the treatment of uncoilable intradural pseudoaneurysms. Neurosurgery 59:291–300 (discussion 291–300). doi:10.1227/01.NEU.0000223650.11954.6C

    Article  PubMed  Google Scholar 

  12. Henkes H, Bose A, Felber S et al (2002) Endovascular coil occlusion of intracranial aneurysms assisted by a novel self-expandable nitinol microstent (Neuroform). Interventional Neuroradiol 8:107–119

    Google Scholar 

  13. Wanke I, Doerfler A, Schoch B et al (2003) Treatment of wide-necked intracranial aneurysms with a self-expanding stent system: initial clinical experience. AJNR Am J Neuroradiol 24:1192–1199

    PubMed  Google Scholar 

  14. Lylyk P, Ferrario A, Pasbon B et al (2005) Buenos Aires experience with the Neuroform self-expanding stent for the treatment of intracranial aneurysms. J Neurosurg 102:235–241

    Article  PubMed  Google Scholar 

  15. Biondi A, Janardhan V, Katz JM et al (2007) Neuroform stent-assisted coil embolization of wide-neck intracranial aneurysms: strategies in stent deployment and midterm follow-up. Neurosurgery 61:460–468 (discussion 468–469)

    Article  PubMed  Google Scholar 

  16. Roy D, Milot G, Raymond J (2001) Endovascular treatment of unruptured aneurysms. Stroke 32:1998–2004. doi:10.1161/hs0901.095600

    Article  PubMed  CAS  Google Scholar 

  17. Fiorella D, Albuquerque FC, Deshmukh VR et al (2005) Usefulness of the Neuroform stent for the treatment of cerebral aneurysms: results at initial (3–6-mo) follow-up. Neurosurgery 56:1191–1201 (discussion 1201–1192). doi:10.1227/01.NEU.0000159645.86823.AF

    Article  PubMed  Google Scholar 

  18. Szikora I, Berentei Z, Kulcsar Z et al (2006) Endovascular treatment of intracranial aneurysms with parent vessel reconstruction using balloon and self expandable stents. Acta Neurochir (Wien) 148:711–723 (discussion 723). doi:10.1007/s00701-006-0785-6

    Article  CAS  Google Scholar 

  19. Wakhloo AK, Schellhammer F, de Vries J et al (1994) Self-expanding and balloon-expandable stents in the treatment of carotid aneurysms: an experimental study in a canine model. AJNR Am J Neuroradiol 15:493–502

    PubMed  CAS  Google Scholar 

  20. Hirabayashi M, Ohta M, Rufenacht DA et al (2003) Characterization of flow reduction properties in an aneurysm due to a stent. Phys Rev E Stat Nonlin Soft Matter Phys 68:021918. doi:10.1103/PhysRevE.68.021918

    PubMed  Google Scholar 

  21. Lopes D, Sani S (2005) Histological postmortem study of an internal carotid artery aneurysm treated with the Neuroform stent. Neurosurgery 56:E416 (discussion E416). doi:10.1227/01.NEU.0000147977.07736.66

    Article  PubMed  Google Scholar 

  22. Akpek S, Arat A, Morsi H et al (2005) Self-expandable stent-assisted coiling of wide-necked intracranial aneurysms: a single-center experience. AJNR Am J Neuroradiol 26:1223–1231

    PubMed  Google Scholar 

  23. Howington JU, Hanel RA, Harrigan MR et al (2004) The Neuroform stent, the first microcatheter-delivered stent for use in the intracranial circulation. Neurosurgery 54:2–5. doi:10.1227/01.NEU.0000099370.05758.4D

    Article  PubMed  Google Scholar 

  24. Higashida RT, Halbach VV, Dowd CF et al (2005) Initial clinical experience with a new self-expanding nitinol stent for the treatment of intracranial cerebral aneurysms: the Cordis Enterprise stent. AJNR Am J Neuroradiol 26:1751–1756

    PubMed  Google Scholar 

  25. Pumar JM, Blanco M, Vazquez F et al (2005) Preliminary experience with Leo self-expanding stent for the treatment of intracranial aneurysms. AJNR Am J Neuroradiol 26:2573–2577

    PubMed  Google Scholar 

  26. Wells-Roth D, Biondi A, Janardhan V et al (2005) Endovascular procedures for treating wide-necked aneurysms. Neurosurg Focus 18:E7. doi:10.3171/foc.2005.18.2.8

    Article  PubMed  Google Scholar 

  27. Yahia AM, Gordon V, Whapham J et al (2008) Complications of Neuroform stent in endovascular treatment of intracranial aneurysms. Neurocrit Care 8:19–30. doi:10.1007/s12028-007-9001-7

    Article  PubMed  Google Scholar 

  28. Yavuz K, Geyik S, Pamuk AG et al (2007) Immediate and midterm follow-up results of using an electrodetachable, fully retrievable SOLO stent system in the endovascular coil occlusion of wide-necked cerebral aneurysms. J Neurosurg 107:49–55. doi:10.3171/JNS-07/07/0049

    Article  PubMed  Google Scholar 

  29. Vanninen R, Manninen H, Ronkainen A (2003) Broad-based intracranial aneurysms: thrombosis induced by stent placement. AJNR Am J Neuroradiol 24:263–266

    PubMed  Google Scholar 

  30. Fiorella D, Thiabolt L, Albuquerque FC et al (2005) Antiplatelet therapy in neuroendovascular therapeutics. Neurosurg Clin N Am 16:517–540. doi:10.1016/j.nec.2005.03.003

    Article  PubMed  Google Scholar 

  31. Standhardt H, Boecher-Schwarz H et al (2008) Endovascular treatment of unruptured intracranial aneurysms with Guglielmi detachable coils: short- and long-term results of a single-centre series. Stroke 39:899–904. doi:10.1161/STROKEAHA.107.496372

    Article  PubMed  Google Scholar 

  32. Gallas S, Drouineau J, Gabrillargues J et al (2008) Feasibility, procedural morbidity and mortality, and long-term follow-up of endovascular treatment of 321 unruptured aneurysms. AJNR Am J Neuroradiol 29:63–68. doi:10.3174/ajnr.A0757

    Article  PubMed  CAS  Google Scholar 

  33. Lee DH, Arat A, Morsi H et al (2008) Dual antiplatelet therapy monitoring for neurointerventional procedures using a point-of-care platelet function test: a single-center experience. AJNR Am J Neuroradiol 29:1389–1394. doi:10.3174/ajnr.A1070

    Article  PubMed  CAS  Google Scholar 

  34. Gurbel PA, Bliden KP, Hiatt BL et al (2003) Clopidogrel for coronary stenting: response variability, drug resistance, and the effect of pretreatment platelet reactivity. Circulation 107:2908–2913. doi:10.1161/01.CIR.0000072771.11429.83

    Article  PubMed  Google Scholar 

  35. Muller I, Besta F, Schulz C et al (2003) Prevalence of clopidogrel non-responders among patients with stable angina pectoris scheduled for elective coronary stent placement. Thromb Haemost 89:783–787

    PubMed  CAS  Google Scholar 

  36. Matetzky S, Shenkman B, Guetta V et al (2004) Clopidogrel resistance is associated with increased risk of recurrent atherothrombotic events in patients with acute myocardial infarction. Circulation 109:3171–3175. doi:10.1161/01.CIR.0000130846.46168.03

    Article  PubMed  CAS  Google Scholar 

  37. Katsaridis V, Papagiannaki C, Violaris C (2006) Embolization of acutely ruptured and unruptured wide-necked cerebral aneurysms using the neuroform2 stent without pretreatment with antiplatelets: a single center experience. AJNR Am J Neuroradiol 27:1123–1128

    PubMed  CAS  Google Scholar 

  38. Hsu SW, Chaloupka JC, Feekes JA et al (2006) In vitro studies of the neuroform microstent using transparent human intracranial arteries. AJNR Am J Neuroradiol 27:1135–1139

    PubMed  Google Scholar 

  39. Raymond J, Guilbert F, Weill A et al (2003) Long-term angiographic recurrences after selective endovascular treatment of aneurysms with detachable coils. Stroke 34:1398–1403. doi:10.1161/01.STR.0000073841.88563.E9

    Article  PubMed  Google Scholar 

  40. Gauvrit JY, Caron S, Taschner CA et al (2008) Intracranial aneurysms treated with Guglielmi detachable coils: long-term imaging follow-up with contrast-enhanced magnetic resonance angiography. J Neurosurg 108:443–449. doi:10.3171/JNS/2008/108/3/0443

    Article  PubMed  Google Scholar 

  41. Fiorella D, Albuquerque FC, Deshmukh VR et al (2004) In-stent stenosis as a delayed complication of neuroform stent-supported coil embolization of an incidental carotid terminus aneurysm. AJNR Am J Neuroradiol 25:1764–1767

    PubMed  Google Scholar 

  42. Juszkat R, Nowak S, Smol S et al (2007) Leo Stent for endovascular treatment of broad-necked and fusiform intracranial aneurysms. Interventional Neuroradiol 13:255–269

    Google Scholar 

  43. Turk AS, Niemann DB, Ahmed A et al (2007) Use of self-expanding stents in distal small cerebral vessels. AJNR Am J Neuroradiol 28:533–536. doi:10.3174/ajnr.A0713

    Article  PubMed  CAS  Google Scholar 

Download references

Conflict of interest statement

We declare that we have no conflict of interest.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Jacques Sedat.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Sedat, J., Chau, Y., Mondot, L. et al. Endovascular occlusion of intracranial wide-necked aneurysms with stenting (Neuroform) and coiling: mid-term and long-term results. Neuroradiology 51, 401–409 (2009). https://doi.org/10.1007/s00234-009-0502-2

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00234-009-0502-2

Keywords

Navigation