Skip to main content

Advertisement

Log in

Quantitative Assessment of Experimental Fracture Repair by Peripheral Computed Tomography

  • Published:
Calcified Tissue International Aims and scope Submit manuscript

Abstract.

An experimental fracture model was used to assess bone mineral density at the fracture site by peripheral computed tomography and to compare the model with biomechanical, histological, and radiographic methods for the quantification of the fracture repair process. Transverse osteotomies in the mid-diaphysis of 28 tibia of sheep were externally fixed and mineral densities, cross-sectional areas, flexural rigidities, tissue composition, and projected callus area were calculated after 9 weeks of healing time. BMD measured by pQCT was strongly correlated with histologically determined percentages of mineralized tissue in the osteotomy gap (R 2= 0.71) and in the periosteal callus (R 2= 0.62). The percentage of mineralized tissue in the osteotomy gap was the best predictor of the flexural rigidity of the tibiae (R 2= 0.74). Because of high correlations with the histological findings, the volumetric BMD at the level of the osteotomy gap was also strongly correlated with the biomechanical findings (R 2= 0.70). Neither the cross-sectional area in pQCT nor the projected callus area in plane film radiography were positively correlated to the flexural rigidity of the tibiae.

Quantitative computed tomography proved to be a successful estimator for the prediction of the mechanical stability of healing bones. The noninvasive procedure is a reliable tool for the quantification of the fracture repair process in experimental studies and may be useful for treatment decisions in particular clinical situations.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received: 2 May 1996 / Accepted: 24 June 1996

Rights and permissions

Reprints and permissions

About this article

Cite this article

Augat, P., Merk, J., Genant, H. et al. Quantitative Assessment of Experimental Fracture Repair by Peripheral Computed Tomography. Calcif Tissue Int 60, 194–199 (1997). https://doi.org/10.1007/s002239900213

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s002239900213

Navigation