Rapid detection of pork meat freshness by using L-cysteine-modified gold electrode

  • Original Paper
  • Published:
European Food Research and Technology Aims and scope Submit manuscript

Abstract

In this research, a simple and rapid glucose sensor was developed and applied in the detection of meat glucose. The gold electrode was modified using L-cysteine and nanogold solution, and a polyglutamate–glucose oxidase (GOx) complex was prepared and dropped on the modified electrode; the electrostatic binding between the L-cysteine on the electrode surface and the polyglutamate moiety of the complex resulted in the formation of a GOx-attached electrode. Glucose in meat was detected, and the enzyme electrode showed a quick response. The optimum operating conditions for this sensor were determined as follows: 0.1 M citrate buffer pH 5.0 was found to be suitable for this experiment, and the temperature was kept between 25 and 30 °C which is the suitable range for the GOx activity. A linear relationship was found between 0.1 and 0.9 mM/mL. High pressure liquid chromatography (HPLC) was also used to detect pork meat glucose, and total volatile basic nitrogen (TVBN) production was as well detected as a quality index of pork meat freshness. The results showed that the developed sensor was fast and reliable method for the detection of glucose in meat.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6

Similar content being viewed by others

References

  1. Arslan F (2008) An amperometric biosensor for uric acid determination prepared from uricase immobilized in polyaniline-polypyrrole film. Sensors 8:5492–5500

    Article  CAS  Google Scholar 

  2. Bharati S, Nogami M, Lev O (2001) Electrochemical organization of gold nanoclusters in three dimensions as thin films from an aminosilicate-stabilized gold sol and their characterization. Langmuir 17:2602–2609

    Article  Google Scholar 

  3. Chaplin MF (1986) Monosaccharides. In: Chaplin MF, Kennedy JF (eds) Carbohydrate analysis: a practical approach. IRL Press, Oxford, pp 1–36

    Google Scholar 

  4. Clark LC, Lyons C (1962) Electrode systems for continuous monitoring in cardiovascular surgery. Ann. N.Y. Acad Sci 102:29–45

    Article  CAS  Google Scholar 

  5. Dattelbaum MA, Baker GA, Fox MJ, Iyer S, Dattelbaum DJ (2009) PEGylation of maltose biosensor promotes enhanced signal response when immobilized in a Silica sol-gel. Bioconjug Chem 20:2381–2384

    Article  CAS  Google Scholar 

  6. Ellis DI, Goodacre R (2001) Rapid and quantitative detection of the microbial spoilage of muscle foods: current and future trends. Trends Food Sci Technol 12:414–424

    Article  CAS  Google Scholar 

  7. Farber MJ, Idziak SE (1982) Detection of glucose oxidation products in chilled fresh beef undergoing spoilage. Appl Environ Microbiol 44:521–524

    CAS  Google Scholar 

  8. Favre E, Pugeaud P, Peringer P (1990) Automated HPLC monitoring of glucose, glutamine, lactate and alanine on suspended mammalian cell reactors. Biotech Tech 4(5):315–320

    CAS  Google Scholar 

  9. Gallego FL, Betancor L, Mateo C, Hidalgo A, Morales NA, Ortiz GD, Guisan JM, Lafuente RF (2005) Enzyme stabilization by glutaraldehyde crosslinking of adsorbed proteins on aminated supports. Biotechnology 119:70–75

    Article  Google Scholar 

  10. Ghindilis AL, Atanasov P, Wilkins E (1997) Enzyme-catalyzed direct electron transfer: fundamentals and analytical applications. Electroanalysis 9:661–674

    Article  CAS  Google Scholar 

  11. Hamaguchi PY, Weng WY, Kobayashi T, Runglertkreingkrai J, Tanaka M (2007) Effect of fish meat quality on the properties of biodegradable protein films. Food Sci Technol Res 13(3):200–204

    Article  CAS  Google Scholar 

  12. Hernandez P, Vicente J, Hernandez L (2003) Self-assembled monolayer of L-cysteine on a gold electrode as a support for fatty acid. Application to the electroanalytical determination of unsaturated fatty acid. Electroanalysis 15(20):1625–1631

    Article  CAS  Google Scholar 

  13. Iwuoha I E, Rock A, Smyth R M (1999) Amperometric L-Lactate biosensors: 1. lactic acid sensing electrode containing lactate oxidase in a composite poly-L-lysine matrix. Electroanalysis 11(5):367–373

    Google Scholar 

  14. Jackson TC, Acuff GR, Dickson JS (1997) Meat, poultry and seafood. In: Doyle MP, Beuchat LR, Montville TJ (eds) Food microbiology: fundamentals and frontiers. Blackwell Publishing Professionals, Iowa, USA, pp 83–100

    Google Scholar 

  15. Liu S, Yu J, Ju H (2003) Renewable phenol biosensor based on a tyrosinase-colloidal gold modified carbon paste electrode. Electroanal Chem 540:61–67

    Article  CAS  Google Scholar 

  16. Liu Y, Wang M, Zhao F, Xu Z, Dong S (2005) The direct electron transfer of glucose oxidase and glucose biosensor based on carbon nanotubes/chitosan matrix. Biosens Bioelectron 21:984–988

    Article  CAS  Google Scholar 

  17. Male KB, Gartu OP, Kamen AA, Luong HT (1997) On-line monitoring of glucose in mammalian cell culture using a flow injection analysis (FIA) mediated biosensor. Biotechnol Bioeng 55:497–504

    Article  CAS  Google Scholar 

  18. Mignani A, Scavetta E, Tonelli D (2006) Electrodeposited glucose oxidase/anionic clay for glucose biosensors design. Anal Chim Acta 577:98–106

    Article  CAS  Google Scholar 

  19. Nychas G-J E, Tassou CC (1997) Spoilage processes and proteolysis in chicken as detected by HPLC. Sci Food Agric 74:199–208

    Article  Google Scholar 

  20. Paramithiotis S, Skandamis PN, Nychas EGJ (2009) Safety of meat and processed meat. Food microbiology and food safety. Springer Science, New York, pp 55–80

    Google Scholar 

  21. Pingarron M, Sedeno P, Cortes G (2008) Gold nanoparticle-based electrochemical biosensors. Electrochim Acta 53:5848–5866

    Article  CAS  Google Scholar 

  22. Plaga A, Stumpfel J, Fiedler H (1989) Determination of carbohydrates in fermentation processes by high performance liquid chromatography. Appl Microbiol Biotechnol 32:45–49

    Article  CAS  Google Scholar 

  23. Rotariu L, Bala C, Magearu V (2002) Yeast cells sucrose biosensor based on a potentiometric oxygen electrode. Anal Chim Acta 458:215–222

    Article  CAS  Google Scholar 

  24. Santos E, Avalle L, Otting K, Elez P, Jones H (2008) Experimental and theoretical studies of l-cysteine adsorbed at Ag (1 1 1) electrodes. Electrochim Acta 53:6807–6817

    Article  CAS  Google Scholar 

  25. Shan D, Zhu M, Xue H, Cosnier S (2007) Inner epidermis of onion bulb scale: as natural support for immobilization of glucose oxidase and its application in dissolved oxygen based biosensor. Biosens Bioelectron 22:1612–1617

    Article  CAS  Google Scholar 

  26. Siddaiah D, Reddy G, Raju C, Chandrasekhar T (2001) Changes in lipids, proteins and kamaboko forming ability of silver carp (Hypophthalmichthys molitrix) mince during frozen storage. Food Res Int 34:47–53

    Article  CAS  Google Scholar 

  27. Stanbridge L, Davies A (1998) The microbiology of chill-stored meat. In: Davies A, Board R (eds) The microbiology of meat and poultry. St. Edmundsbury Press Ltd, Great Britain, pp 174–219

    Google Scholar 

  28. Watanabe E, Endo H, Ikeda Y, Shibamoto N, Toyama K (1986) Determination of glucose in fish muscle and serum with an enzyme sensor. Bull Jpn Soc Sci Fish 52(4):711–717

    CAS  Google Scholar 

  29. Xian Y, Hu Y, Liu F, Wang H, Jin L (2006) Template synthesis of highly ordered Prussian blue array and its application to the glucose biosensing. Biosens Bioelectron 22:2827–2833

    Article  Google Scholar 

  30. Yabuki S, Mizutani F, Sato Y, Hirata Y (2003) Immobilization of polyglutamate-glucose oxidase onto a cysteamine-modified gold electrode. Sens Actuators B 91:187–190

    Article  Google Scholar 

  31. Yang Y, Zhong Z, Liu H, Zhu T, Wu J, Li M, Wang D (2008) Double-layer nanogold and double-strand DNA-modified electrode for electrochemical immunoassay of cancer antigen 15–3. Electroanalysis 20:2621–2628

    Article  CAS  Google Scholar 

  32. Zhang F, Wang X, Ai S, Sun Z, Wan Q, Zhu Z, Xian Y, Jin L, Yamamoto K (2004) Mechanism of electron cloud clearing in the accumulator ring of the spallation neutron source. Anal Chem Acta 519:155–160

    Article  CAS  Google Scholar 

  33. Zhang S, Wang N, Niu Y, Li F, Song J, Han D, Ivaska A, Sun C (2005) Immobilization of glucose oxidase on gold nanoparticles modified Au electrode for the construction of biosensor. Sens Actuators B 109:367–374

    Article  Google Scholar 

  34. Zhao S, Zhang K, Bai Y, Yang W, Sun C (2006) Glucose oxidase/colloidal gold nanoparticles immobilized in Nafion film on glassy carbon electrode: direct electron transfer and electrocatalysis. Bioelectrochemistry 69:158–163

    Article  CAS  Google Scholar 

Download references

Acknowledgments

This research work was founded by the financial assistance of the National High Technology Research and Development Program of China. Our appreciation to all those whom in diverse ways contributed to this research.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Xiulan Sun.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Umuhumuza, L.C., Sun, X. Rapid detection of pork meat freshness by using L-cysteine-modified gold electrode. Eur Food Res Technol 232, 425–431 (2011). https://doi.org/10.1007/s00217-010-1405-5

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00217-010-1405-5

Keywords

Navigation