A fast and selective enzymatic method for the determination of salicylate in beverages and cosmetics has been developed. The enzyme salicylate hydroxylase was immobilised covalently onto a glassy carbon working electrode of a wall-jet cell coupled with a flowinjection analysis system. The salicylate is enzymatically converted to catechol, which can be detected amperometrically on the glassy carbon electrode at + 0.45 V. The response of the biosensor is linearly proportional to the concentration of salicylate between 725 nmol/l and 700 μmol/l. A high sample throughput (60 h−1) is possible, and the biosensor is stable for more than three months. Sample pretreatment for beverages and hair lotions is easy and fast. For creams, an extraction of salicylate is necessary. Relative standard deviations are less than 5.5% and the recoveries are between 95 and 105%.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Hornstein OP, Nürnberg E (1985) Externe Therapie von Hautkrankheiten. Pharmazeutische und Medizinische Praxis. Thieme, Stuttgart, p 149, p 162

    Google Scholar 

  2. Hingst W (1985) Zeitbombe Kosmetik. Orac, p 78, p 160

  3. Lück E (1977) Chemische Lebensmittelkonservierung. Springer, Berlin Heidelberg New York, pp 186–189

    Google Scholar 

  4. Borchert C, Krüger E (1989) Monatsschr Brauwiss 42: 438–442

    CAS  Google Scholar 

  5. Saha U, Baksi K (1985) Analyst 110: 739–741

    Article  CAS  Google Scholar 

  6. Adams S, Miller J (1978) J Pharm Pharmacol 30: 81–84

    CAS  Google Scholar 

  7. Molokhia AM, Al-Shora HI, Al-Rhaman S (1985) J Liquid Chromatogr 8: 2093–2103

    Article  CAS  Google Scholar 

  8. Carlson M, Thompson RD (1987) J Liquid Chromatogr 10: 997–1009

    Article  CAS  Google Scholar 

  9. Flak W, Schaber R (1988) Mitt Klosterneuburg 38: 10–16

    CAS  Google Scholar 

  10. Mitsana-Papazoglou A, Diamandis EP, Hadjiioannou TP (1984) Anal Chim Acta 159: 393–396

    Article  CAS  Google Scholar 

  11. Hassan SM, Hamada MA (1988) Analyst 113: 1709–1713

    Article  CAS  Google Scholar 

  12. Fung YS, Luk SF (1989) Analyst 114: 943–945

    Article  CAS  Google Scholar 

  13. Neumayr M, Sontag G, Pittner F (1995) Anal Chim Acta 305: 26–31

    Article  CAS  Google Scholar 

  14. White-Stevens RH, Kamin H (1972) J Biol Chem 247: 2358–2370

    CAS  Google Scholar 

  15. Kamin H, White-Stevens RH, Presswood RP (1978) Meth Enzymol 52: 527–543

    Article  Google Scholar 

  16. Mann-Buxbaum E (1990) Thesis, University of Vienna

  17. Longecker RW, Trafton JE, Edwards RB (1984) Clin Chem 30: 1369–1371

    Google Scholar 

  18. Rahni MAN, Guilbault GG, de Oliveira GN (1986) Anal Chim Acta 181: 219–225

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

Dedicated to em.o.Prof.Dr. G. Kainz on the occasion of his 75th birthday.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Ehrendorfer, M., Sontag, G. & Pittner, F. Determination of salicylate in beverages and cosmetics by use of an amperometric biosensor. Fresenius J Anal Chem 356, 75–79 (1996). https://doi.org/10.1007/s0021663560075

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s0021663560075

Keywords

Navigation